Aili Zhang

Aili Zhang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Aili Zhang has a total of 97 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Electrothermal decoupling for investigating tumor treating fields of glioblastoma

    by Bo Cao, Linyang Wei, Wenhao Zhu, Hongying Wang, Ming Xu, Shiqing Zhao, Hongzhi Xu, Aili Zhang

    Objective: Tumor Treating Fields (TTFields), a non-invasive cancer therapy employing low-intensity alternating electric fields to inhibit cancer cell division, has been used to treat glioblastoma. While clinically established for glioblastoma, the biological contribution of the intrinsic mild hyperthermia (iMH) remains not fully elucidated, limiting mechanistic clarity and treatment optimization. Approach: This study presents a precision in vitro platform designed to decouple the electrical and thermal components of TTFields (230 kHz, 2 V/cm). Based on numerical simulations, the platform utilizes a defined monitoring area to ensure field uniformity and an active thermodynamic compensation protocol to isolate electric and thermal modalities. Main results: Results indicated that the electric field primarily inhibited cell proliferation (32.0% reduction) and migration, whereas the iMH was the primary mediator of cytotoxicity and apoptosis. Notably, the combined electrothermal treatment exhibited a synergistic anti-tumor effect exceeding the additive effects of individual modalities. Significance: These findings suggest that the iMH component of TTFields functions as a therapeutic sensitizer rather than a side effect, offering a basis for optimizing future GBM treatment strategies.


  • Development and Experimental Validation of a High-Precision Voltage and Power-Controlled Radiofrequency Ablation System

    by Jincheng Zou, Bo Cao, Shasha Ren, Aili Zhang

    To design and validate a real-time precision control system for radiofrequency ablation (RFA) that counteracts power instability from dynamic tissue impedance, ensuring accurate and predictable energy delivery.An integrated system was developed with high-precision RF signal acquisition and two novel algorithms: an impedance-adaptive voltage correction to eliminate measurement errors, and a Taylor series-based feedforward control for rapid ($< $ 50ms) power adjustments. Performance was validated using an electrosurgical analyzer (20-500 $\Omega$ load range) and through ex vivo ablation experiments on porcine liver, chicken breast, and pork tissues.The system achieved high measurement accuracy, with voltage/current errors $< $ 3% and impedance/power errors $< $ 4%. The impedance-adaptive algorithm reduced voltage control error by 90% under non-nominal loads. Ex vivo ablations demonstrated excellent lesion repeatability, with ablation zone area discrepancies under 1.24%. The integrated hardware-software solution provides a validated method to enhance the predictability and consistency of RFA. Ensuring consistent RFA energy delivery, this technology creates predictable ablation zones, enhancing efficacy and safety by reducing tumor recurrence and minimizing damage to surrounding healthy tissue.

  • Open Access

    A High-Efficiency Inductive Antenna System With a Magnetic Focusing Unit and a Matching Module for Wireless Hyperthermia: Design and Verification

    by Shasha Ren, Jincheng Zou, Aili Zhang

    Wireless power transfer (WPT) has emerged as a transformative technology for applications ranging from biomedical implants to remote sensing. However, conventional WPT systems face limitations in power transfer efficiency, and particularly a significant attenuation occurs when high-frequency powers penetrate dense media like biological tissue. This work introduces a high-efficiency antenna system designed for wireless hyperthermia in peripheral arteries, which demonstrates enhanced penetration capability through biological tissues, making it ideal for powering deep-tissue medical implants with medium power (from 1w to 100w). The innovative antenna system comprises a coil, an external ferrite-based magnetic focusing unit (MFU), and an impedance matching module. The optimized leakage-shaped MFU was simulated and found to result in 2.1∼6.6× increase in magnetic field strength. The measured port gain of our antenna system, which reflects the efficiency of WPT, increases by 7.7∼14 dBm compared to the conventional coil antenna. Moreover, the receiver was powered with still 95% of maximum voltage despite a 30° angular deviation, showing adaptability to misalignments. The integrated matching module achieves impedance transformation to 50 Ω at 1.5 MHz. After matching, the reflection coefficient S11 of the antenna is −30 dBm and the port gain rises up by 32 dBm. In the heating test, a 40% increase in heating rate is achieved. Power transfer efficiency (PTE) is 33-25% and heating efficiency (HE) is 4.6-3.1 °C/W through a 1.5–2.5 cm phantom thickness. The demonstrated enhancement of the proposed antenna system suggests it to be a promising method for in-vivo deep (a few centimeters) wireless hyperthermia treatment.

  • Personalized modeling for in vivo multimodal thermal therapy planning based on preoperative MRI

    by Qizheng Dai, Aili Zhang, Lisa X. Xu

    Background: Accurate treatment dosage planning depends on the personalized thermal response in vivo. Purpose: This study proposes a personalized model by incorporating personalized thermal conductivity derived from the preoperative magnetic resonance imaging (MRI) characteristics of targeted tumors. Methods: Ten female New Zealand rabbits with subcutaneous VX2 tumors underwent multimodal thermal therapy. An individual coefficient () was determined from reconstructed temperature mapping to estimate the effective thermal conductivity. Preoperative T2‐weighted (T2W) and T1‐weighted (T1W) MRI images were acquired, with defined as the ratio of mean signal intensity of the T2W images to that of the T1W images. The ratio of the value between the tumor and the adjacent muscularis propria (represented as ) was used to establish a quantified relationship with the individual coefficient (). The fitness using linear function and several common nonlinear functions were compared in the leave one out cross validation (LOOCV) to assess the precision and degree of overfitting. Additionally, a sensitivity analysis on the linear fitting to variations on MRI characteristics was conducted. Furthermore, the temperature distributions in tumors with varied parameters and freezing temperatures were predicted for preoperative planning. Results: Effective thermal conductivity was fitted as a weighted combination of water (weighted by an individual coefficient , ranging from 0.5 to 0.75), and a baseline value of 0.16 W/m/K (weighted by ). The root mean square errors (RMSE) between reconstructed and experimental temperatures were 3.40 2.32 and 0.80 0.53 in transient and steady states, respectively. Quantified correlation between and the individual coefficient was explored and validated. Compared to the nonlinear correlations studied, no significant difference in residuals was observed, while the fitness using quadratic or cubic functions exhibited signs of overfitting with significantly increased AIC/BIC. The linear function was selected for prediction and sensitivity analysis. Using the predicted effective thermal conductivity, the RMSE were 3.79 2.16 and 1.24 0.46 in the transient and steady states, respectively, significantly lower than those from conventional model ( p < 0.01 and p < 0.05, respectively). The model remained robust to 10% perturbation error on preoperative MRI characteristics. In large tumors with low individual coefficient , personalized model reduced overestimation on ‐20 isothermal region by 15.11 mm compared to the conventional model. Conclusions: Preoperative MRI provided a quantified and user‐friendly tool for improving accuracy of personalized model on thermal dosage planning.


  • Open Access

    Programmable conformal transluminal ablation device for irregular remote small lesions

    by Ruizhe Hou, Hongying Wang, Jincheng Zou, Bo Cao, Shiqing Zhao, Aili Zhang

  • Study of Histotripsy With Subsequent Heating on In Vitro VX2 Cancer Cells

    by Qizheng Dai, Lisa X. Xu, Aili Zhang, J. Brian Fowlkes

    Objective: Focused ultrasound has emerged as a precise and minimally invasive modality for effective cancer treatment. In this study, we propose a novel method that integrates the mechanical effects of focused ultrasound, known as histotripsy, with heating to enhance both the immediate and sustained cytotoxic effects on cancer cells.Methods: Our investigation focused on VX2 cancer cells in suspension, examining five experimental groups: blank control, negative control, heating alone, histotripsy alone, and histotripsy with subsequent heating. B‐mode ultrasound imaging was utilized to visualize cavitation bubble cloud formation and its motion during histotripsy. The suspension was contained in individually sealed compartments obtained from bubble wrap (referred to as bubble wrap compartments) embedded within the agarose phantom. Residual living cells were examined immediately after treatment and cultured for 96 hours to analyze the growth patterns. Additionally, CFDA SE staining was employed to assess cell proliferation. Furthermore, both intracellular and extracellular heat shock protein 70 (HSP70) levels were measured to investigate the potential initiation of an immune response.Results: The combination of histotripsy and subsequent heating significantly reduced the normalized concentration of living cells immediately after treatment. It also decreased the proliferation rate of residual cells compared with the other experimental groups. Histotripsy with subsequent heating also increased the generation and release of HSP70, which might potentially enhance an innate anti‐tumor immune response in vivo.Conclusion: Histotripsy and subsequent heating improved the immediate lethal impact on VX2 cancer cells and curtailed the proliferation of residual cancer cells in suspension. This study presents a promising strategy for cancer therapy in the future.


  • Open Access

    Image-Based Monitoring of Thermal Ablation

    by Xinyi Wang, Shiqing Zhao, Aili Zhang

    Thermal therapy is a commonly used local treatment technique in clinical practice. Monitoring the treatment process is essential for ensuring its success. In this review, we analyze recent image-based methods for thermal therapy monitoring, focusing particularly on their feasibility for synchronous or immediate postoperative monitoring. This includes thermography and other techniques that track the physical changes in tissue during thermal ablation. Potential directions and challenges for further clinical applications are also summarized.


  • Optimization of three-dimensional esophageal tumor ablation by simultaneous functioning of multiple electrodes

    by Hongying Wang, Jincheng Zou, Shiqing Zhao, Aili Zhang

    Radiofrequency ablation is a widely accepted minimal-invasive and effective local treatment for tumors. However, its current application in esophageal cancer treatment is limited to targeting thin and superficial lesions, such as Barrett's Esophagus. This study proposes an optimization method using multiple electrodes simultaneously to regulate the temperature field and achieve conformal ablation of tumors. A particle swarm optimization algorithm, coupled with a three-dimensional thermal ablation model, was developed to optimize the status of the functioning electrodes, the optimal voltage (Vopt), and treatment duration (ttre) for targeted esophageal tumors. This approach takes into account both the electrical and thermal interactions of the electrodes. The results indicate that for esophageal cancers at various stages, with thickness (c) ranging from 4.5 mm to 10.0 mm, major axis (a) ranging from 7.3 mm to 27.3 mm, and minor axis (b) equaling 7.3 mm or 27.3 mm, as well as non-symmetrical geometries, complete tumor coverage (over 99.5%) close to conformal can be achieved. This method illustrates possible precise conformal ablation of esophageal cancers and it may also be used for conformal treatments of other intraluminal lesions. Graphical Abstract