Bengie L. Ortiz
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Bengie L. Ortiz has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Jo Woon Chong
School of Electronic and Electrical Engineering, Sungkyunkwan University, Suwon, Republic of Korea
4 shared publications - Vibhuti Gupta
Department of Biostatistics & Data Science, University of Texas Medical Branch, Galveston, USA
4 shared publications - Rajnish Kumar
Department of Pediatrics, Hematology and Oncology Division, Michigan Medicine, University of Michigan Health System Ann Arbor, MI United States
3 shared publications - Sung Won Choi
Department of Pediatrics, University of Michigan, Ann Arbor, MI, USA
3 shared publications - Xiao Cao
Department of Pediatrics, Medical School, University of Michigan, Ann Arbor, MI, United States
3 shared publications - Aditya Jalin
Department of Pediatrics, University of Michigan, Ann Arbor, USA
2 shared publications
Latest Publications
- Open Access
- 27 September 2024
- Published by JMIR Publications Inc. in JMIR mHealth and uHealth
- Vol. 12 (1) , e59587
Data Preprocessing Techniques for AI and Machine Learning Readiness: Scoping Review of Wearable Sensor Data in Cancer Care
Background: Wearable sensors are increasingly being explored in health care, including in cancer care, for their potential in continuously monitoring patients. Despite their growing adoption, significant challenges remain in the quality and consistency of data collected from wearable sensors. Moreover, preprocessing pipelines to clean, transform, normalize, and standardize raw data have not yet been fully optimized. Objective: This study aims to conduct a scoping review of preprocessing techniques used on raw wearable sensor data in cancer care, specifically focusing on methods implemented to ensure their readiness for artificial intelligence and machine learning (AI/ML) applications. We sought to understand the current landscape of approaches for handling issues, such as noise, missing values, normalization or standardization, and transformation, as well as techniques for extracting meaningful features from raw sensor outputs and converting them into usable formats for subsequent AI/ML analysis. Methods: We systematically searched IEEE Xplore, PubMed, Embase, and Scopus to identify potentially relevant studies for this review. The eligibility criteria included (1) mobile health and wearable sensor studies in cancer, (2) written and published in English, (3) published between January 2018 and December 2023, (4) full text available rather than abstracts, and (5) original studies published in peer-reviewed journals or conferences. Results: The initial search yielded 2147 articles, of which 20 (0.93%) met the inclusion criteria. Three major categories of preprocessing techniques were identified: data transformation (used in 12/20, 60% of selected studies), data normalization and standardization (used in 8/20, 40% of the selected studies), and data cleaning (used in 8/20, 40% of the selected studies). Transformation methods aimed to convert raw data into more informative formats for analysis, such as by segmenting sensor streams or extracting statistical features. Normalization and standardization techniques usually normalize the range of features to improve comparability and model convergence. Cleaning methods focused on enhancing data reliability by handling artifacts like missing values, outliers, and inconsistencies. Conclusions: While wearable sensors are gaining traction in cancer care, realizing their full potential hinges on the ability to reliably translate raw outputs into high-quality data suitable for AI/ML applications. This review found that researchers are using various preprocessing techniques to address this challenge, but there remains a lack of standardized best practices. Our findings suggest a pressing need to develop and adopt uniform data quality and preprocessing workflows of wearable sensor data that can support the breadth of cancer research and varied patient populations. Given the diverse preprocessing techniques identified in the literature, there is an urgency for a framework that can guide researchers and clinicians in preparing wearable sensor data for AI/ML applications. For the scoping review as well as our research, we propose a general framework for preprocessing wearable sensor data, designed to be adaptable across different disease settings, moving beyond cancer care.
- 27 September 2024
- Published by JMIR Publications Inc. in JMIR mHealth and uHealth
- Vol. 12 (1) , e59587
Open AccessData Preprocessing Techniques for AI and Machine Learning Readiness: Scoping Review of Wearable Sensor Data in Cancer Care
Background: Wearable sensors are increasingly being explored in health care, including in cancer care, for their potential in continuously monitoring patients. Despite their growing adoption, significant challenges remain in the quality and consistency of data collected from wearable sensors. Moreover, preprocessing pipelines to clean, transform, normalize, and standardize raw data have not yet been fully optimized. Objective: This study aims to conduct a scoping review of preprocessing techniques used on raw wearable sensor data in cancer care, specifically focusing on methods implemented to ensure their readiness for artificial intelligence and machine learning (AI/ML) applications. We sought to understand the current landscape of approaches for handling issues, such as noise, missing values, normalization or standardization, and transformation, as well as techniques for extracting meaningful features from raw sensor outputs and converting them into usable formats for subsequent AI/ML analysis. Methods: We systematically searched IEEE Xplore, PubMed, Embase, and Scopus to identify potentially relevant studies for this review. The eligibility criteria included (1) mobile health and wearable sensor studies in cancer, (2) written and published in English, (3) published between January 2018 and December 2023, (4) full text available rather than abstracts, and (5) original studies published in peer-reviewed journals or conferences. Results: The initial search yielded 2147 articles, of which 20 (0.93%) met the inclusion criteria. Three major categories of preprocessing techniques were identified: data transformation (used in 12/20, 60% of selected studies), data normalization and standardization (used in 8/20, 40% of the selected studies), and data cleaning (used in 8/20, 40% of the selected studies). Transformation methods aimed to convert raw data into more informative formats for analysis, such as by segmenting sensor streams or extracting statistical features. Normalization and standardization techniques usually normalize the range of features to improve comparability and model convergence. Cleaning methods focused on enhancing data reliability by handling artifacts like missing values, outliers, and inconsistencies. Conclusions: While wearable sensors are gaining traction in cancer care, realizing their full potential hinges on the ability to reliably translate raw outputs into high-quality data suitable for AI/ML applications. This review found that researchers are using various preprocessing techniques to address this challenge, but there remains a lack of standardized best practices. Our findings suggest a pressing need to develop and adopt uniform data quality and preprocessing workflows of wearable sensor data that can support the breadth of cancer research and varied patient populations. Given the diverse preprocessing techniques identified in the literature, there is an urgency for a framework that can guide researchers and clinicians in preparing wearable sensor data for AI/ML applications. For the scoping review as well as our research, we propose a general framework for preprocessing wearable sensor data, designed to be adaptable across different disease settings, moving beyond cancer care.
- 21 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Conference proceedings. IEEE Colombian Conference on Communications and Computing
- Vol. 2024, 1-6
Wheeze and Crackle Discrimination Algorithm in Pneumonia Respiratory Signals
A new pneumonia detection method is proposed to provide both pneumonia detection in respiratory sound signals and wheeze and crackle discrimination when pneumonia episodes are detected. In the proposed method, two-step hierarchy, classifying pneumonia in the first step and discriminating wheezing and crackling in the second step, is considered; the conventional pneumonia detection method is modified to improve pneumonia detection performance, while wheezing and crackling discrimination functionality is added to facilitate the application of appropriate remedies for each case. We used resampling techniques to address the imbalance in the ICBHI pneumonia dataset. The random forest algorithm is used to classify pneumonia from healthy respiratory data, as well as to distinguish between wheeze and crackle from pneumonia data. Against the ICBHI respiratory dataset, the proposed random forest-based hierarchy pneumonia detection method provides 85.40% accuracy in detecting pneumonia and 82.70% accuracy in discriminating wheeze from crackling, respectively. Keywords—signal processing, machine learning, audio signals, pneumonia, hierarchical classification.
- 21 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Conference proceedings. IEEE Colombian Conference on Communications and Computing
- Vol. 2024, 1-6
Wheeze and Crackle Discrimination Algorithm in Pneumonia Respiratory Signals
A new pneumonia detection method is proposed to provide both pneumonia detection in respiratory sound signals and wheeze and crackle discrimination when pneumonia episodes are detected. In the proposed method, two-step hierarchy, classifying pneumonia in the first step and discriminating wheezing and crackling in the second step, is considered; the conventional pneumonia detection method is modified to improve pneumonia detection performance, while wheezing and crackling discrimination functionality is added to facilitate the application of appropriate remedies for each case. We used resampling techniques to address the imbalance in the ICBHI pneumonia dataset. The random forest algorithm is used to classify pneumonia from healthy respiratory data, as well as to distinguish between wheeze and crackle from pneumonia data. Against the ICBHI respiratory dataset, the proposed random forest-based hierarchy pneumonia detection method provides 85.40% accuracy in detecting pneumonia and 82.70% accuracy in discriminating wheeze from crackling, respectively. Keywords—signal processing, machine learning, audio signals, pneumonia, hierarchical classification.
- Open Access
- 16 April 2024
- Published by JMIR Publications Inc. in JMIR Preprints
Data Preprocessing Techniques for AI and Machine Learning Readiness: Scoping Review of Wearable Sensor Data in Cancer Care (Preprint)
BACKGROUND Wearable sensors are increasingly being explored in health care, including in cancer care, for their potential in continuously monitoring patients. Despite their growing adoption, significant challenges remain in the quality and consistency of data collected from wearable sensors. Moreover, preprocessing pipelines to clean, transform, normalize, and standardize raw data have not yet been fully optimized. OBJECTIVE This study aims to conduct a scoping review of preprocessing techniques used on raw wearable sensor data in cancer care, specifically focusing on methods implemented to ensure their readiness for artificial intelligence and machine learning (AI/ML) applications. We sought to understand the current landscape of approaches for handling issues, such as noise, missing values, normalization or standardization, and transformation, as well as techniques for extracting meaningful features from raw sensor outputs and converting them into usable formats for subsequent AI/ML analysis. METHODS We systematically searched IEEE Xplore, PubMed, Embase, and Scopus to identify potentially relevant studies for this review. The eligibility criteria included (1) mobile health and wearable sensor studies in cancer, (2) written and published in English, (3) published between January 2018 and December 2023, (4) full text available rather than abstracts, and (5) original studies published in peer-reviewed journals or conferences. RESULTS The initial search yielded 2147 articles, of which 20 (0.93%) met the inclusion criteria. Three major categories of preprocessing techniques were identified: data transformation (used in 12/20, 60% of selected studies), data normalization and standardization (used in 8/20, 40% of the selected studies), and data cleaning (used in 8/20, 40% of the selected studies). Transformation methods aimed to convert raw data into more informative formats for analysis, such as by segmenting sensor streams or extracting statistical features. Normalization and standardization techniques usually normalize the range of features to improve comparability and model convergence. Cleaning methods focused on enhancing data reliability by handling artifacts like missing values, outliers, and inconsistencies. CONCLUSIONS While wearable sensors are gaining traction in cancer care, realizing their full potential hinges on the ability to reliably translate raw outputs into high-quality data suitable for AI/ML applications. This review found that researchers are using various preprocessing techniques to address this challenge, but there remains a lack of standardized best practices. Our findings suggest a pressing need to develop and adopt uniform data quality and preprocessing workflows of wearable sensor data that can support the breadth of cancer research and varied patient populations. Given the diverse preprocessing techniques identified in the literature, there is an urgency for a framework that can guide researchers and clinicians in preparing wearable sensor data for AI/ML applications. For the scoping review as well as our research, we propose a general framework for preprocessing wearable sensor data, designed to be adaptable across different disease settings, moving beyond cancer care.
- 16 April 2024
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessData Preprocessing Techniques for AI and Machine Learning Readiness: Scoping Review of Wearable Sensor Data in Cancer Care (Preprint)
BACKGROUND Wearable sensors are increasingly being explored in health care, including in cancer care, for their potential in continuously monitoring patients. Despite their growing adoption, significant challenges remain in the quality and consistency of data collected from wearable sensors. Moreover, preprocessing pipelines to clean, transform, normalize, and standardize raw data have not yet been fully optimized. OBJECTIVE This study aims to conduct a scoping review of preprocessing techniques used on raw wearable sensor data in cancer care, specifically focusing on methods implemented to ensure their readiness for artificial intelligence and machine learning (AI/ML) applications. We sought to understand the current landscape of approaches for handling issues, such as noise, missing values, normalization or standardization, and transformation, as well as techniques for extracting meaningful features from raw sensor outputs and converting them into usable formats for subsequent AI/ML analysis. METHODS We systematically searched IEEE Xplore, PubMed, Embase, and Scopus to identify potentially relevant studies for this review. The eligibility criteria included (1) mobile health and wearable sensor studies in cancer, (2) written and published in English, (3) published between January 2018 and December 2023, (4) full text available rather than abstracts, and (5) original studies published in peer-reviewed journals or conferences. RESULTS The initial search yielded 2147 articles, of which 20 (0.93%) met the inclusion criteria. Three major categories of preprocessing techniques were identified: data transformation (used in 12/20, 60% of selected studies), data normalization and standardization (used in 8/20, 40% of the selected studies), and data cleaning (used in 8/20, 40% of the selected studies). Transformation methods aimed to convert raw data into more informative formats for analysis, such as by segmenting sensor streams or extracting statistical features. Normalization and standardization techniques usually normalize the range of features to improve comparability and model convergence. Cleaning methods focused on enhancing data reliability by handling artifacts like missing values, outliers, and inconsistencies. CONCLUSIONS While wearable sensors are gaining traction in cancer care, realizing their full potential hinges on the ability to reliably translate raw outputs into high-quality data suitable for AI/ML applications. This review found that researchers are using various preprocessing techniques to address this challenge, but there remains a lack of standardized best practices. Our findings suggest a pressing need to develop and adopt uniform data quality and preprocessing workflows of wearable sensor data that can support the breadth of cancer research and varied patient populations. Given the diverse preprocessing techniques identified in the literature, there is an urgency for a framework that can guide researchers and clinicians in preparing wearable sensor data for AI/ML applications. For the scoping review as well as our research, we propose a general framework for preprocessing wearable sensor data, designed to be adaptable across different disease settings, moving beyond cancer care.
- Open Access
- 18 January 2024
- Published by MDPI AG in Bioengineering
- Vol. 11 (1) , 95
Dyadic and Individual Variation in 24-Hour Heart Rates of Cancer Patients and Their Caregivers
Background: Twenty-four-hour heart rate (HR) integrates multiple physiological and psychological systems related to health and well-being, and can be continuously monitored in high temporal resolution over several days with wearable HR monitors. Using HR data from two independent datasets of cancer patients and their caregivers, we aimed to identify dyadic and individual patterns of 24 h HR variation and assess their relationship to demographic, environmental, psychological, and clinical variables of interest. Methods: a novel regularized approach to high-dimensional canonical correlation analysis (CCA) was used to identify factors reflecting dyadic and individual variation in the 24 h (circadian) HR trajectories of 430 people in 215 dyads, then regression analysis was used to relate these patterns to explanatory variables. Results: Four distinct factors of dyadic covariation in circadian HR were found, contributing approximately 7% to overall circadian HR variation. These factors, along with non-dyadic factors reflecting individual variation exhibited diverse and statistically robust patterns of association with explanatory variables of interest. Conclusions: Both dyadic and individual anomalies are present in the 24 h HR patterns of cancer patients and their caregivers. These patterns are largely synchronous, and their presence robustly associates with multiple explanatory variables. One notable finding is that higher mood scores in cancer patients correspond to an earlier HR nadir in the morning and higher HR during the afternoon.
- 18 January 2024
- Published by MDPI AG in Bioengineering
- Vol. 11 (1) , 95
Open AccessDyadic and Individual Variation in 24-Hour Heart Rates of Cancer Patients and Their Caregivers
Background: Twenty-four-hour heart rate (HR) integrates multiple physiological and psychological systems related to health and well-being, and can be continuously monitored in high temporal resolution over several days with wearable HR monitors. Using HR data from two independent datasets of cancer patients and their caregivers, we aimed to identify dyadic and individual patterns of 24 h HR variation and assess their relationship to demographic, environmental, psychological, and clinical variables of interest. Methods: a novel regularized approach to high-dimensional canonical correlation analysis (CCA) was used to identify factors reflecting dyadic and individual variation in the 24 h (circadian) HR trajectories of 430 people in 215 dyads, then regression analysis was used to relate these patterns to explanatory variables. Results: Four distinct factors of dyadic covariation in circadian HR were found, contributing approximately 7% to overall circadian HR variation. These factors, along with non-dyadic factors reflecting individual variation exhibited diverse and statistically robust patterns of association with explanatory variables of interest. Conclusions: Both dyadic and individual anomalies are present in the 24 h HR patterns of cancer patients and their caregivers. These patterns are largely synchronous, and their presence robustly associates with multiple explanatory variables. One notable finding is that higher mood scores in cancer patients correspond to an earlier HR nadir in the morning and higher HR during the afternoon.
- 22 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2023, 1-6
A Novel Prediction Method for Glaucoma Detection Using Retinographies
Glaucoma, characterized by its damage to the retinal nerve, is one of the most statistically dominant eye diseases in the U.S. It can cause vision loss and blindness by affecting the optic nerve. As the disease progresses, it is not necessarily noticeable to patients, requiring elaborate solutions to manage this critical condition. In this paper, we propose a novel detection model that provides improved accuracy and performance in the detection of glaucoma using retinographies as input. After careful consideration, we adopted multiple features suitable for distinguishing healthy and diseased eyes. Moreover, the adoption, integration, and feature extraction of 3D meshes was a significant factor in developing our glaucoma detection system. With our acquired dataset, we compared the performance of Classification Decision Trees (CDT), Support Vector Machine (SVM), and K-Nearest Neighbor (KNN) in classifying retinographies as being healthy or having glaucoma. Experimental results show that the proposed model methodology can efficiently predict glaucoma detection with 100%, 100%, and 83.3% accuracy from CDT, SVM, and KNN, respectively.
- 22 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2023, 1-6
A Novel Prediction Method for Glaucoma Detection Using Retinographies
Glaucoma, characterized by its damage to the retinal nerve, is one of the most statistically dominant eye diseases in the U.S. It can cause vision loss and blindness by affecting the optic nerve. As the disease progresses, it is not necessarily noticeable to patients, requiring elaborate solutions to manage this critical condition. In this paper, we propose a novel detection model that provides improved accuracy and performance in the detection of glaucoma using retinographies as input. After careful consideration, we adopted multiple features suitable for distinguishing healthy and diseased eyes. Moreover, the adoption, integration, and feature extraction of 3D meshes was a significant factor in developing our glaucoma detection system. With our acquired dataset, we compared the performance of Classification Decision Trees (CDT), Support Vector Machine (SVM), and K-Nearest Neighbor (KNN) in classifying retinographies as being healthy or having glaucoma. Experimental results show that the proposed model methodology can efficiently predict glaucoma detection with 100%, 100%, and 83.3% accuracy from CDT, SVM, and KNN, respectively.
- Open Access
- 30 November 2022
- Published by MDPI AG in Multimodal Technologies and Interaction
- Vol. 6 (12) , 107
User Authentication Recognition Process Using Long Short-Term Memory Model
User authentication (UA) is the process by which biometric techniques are used by a person to gain access to a physical or virtual site. UA has been implemented in various applications such as financial transactions, data privacy, and access control. Various techniques, such as facial and fingerprint recognition, have been proposed for healthcare monitoring to address biometric recognition problems. Photoplethysmography (PPG) technology is an optical sensing technique which collects volumetric blood change data from the subject’s skin near the fingertips, earlobes, or forehead. PPG signals can be readily acquired from devices such as smartphones, smartwatches, or web cameras. Classical machine learning techniques, such as decision trees, support vector machine (SVM), and k-nearest neighbor (kNN), have been proposed for PPG identification. We developed a UA classification method for smart devices using long short-term memory (LSTM). Specifically, our UA classifier algorithm uses raw signals so as not to lose the specific characteristics of the PPG signal coming from each user’s specific behavior. In the UA context, false positive and false negative rates are crucial. We recruited thirty healthy subjects and used a smartphone to take PPG data. Experimental results show that our Bi-LSTM-based UA algorithm based on the feature-based machine learning and raw data-based deep learning approaches provides 95.0% and 96.7% accuracy, respectively.
- 30 November 2022
- Published by MDPI AG in Multimodal Technologies and Interaction
- Vol. 6 (12) , 107
Open AccessUser Authentication Recognition Process Using Long Short-Term Memory Model
User authentication (UA) is the process by which biometric techniques are used by a person to gain access to a physical or virtual site. UA has been implemented in various applications such as financial transactions, data privacy, and access control. Various techniques, such as facial and fingerprint recognition, have been proposed for healthcare monitoring to address biometric recognition problems. Photoplethysmography (PPG) technology is an optical sensing technique which collects volumetric blood change data from the subject’s skin near the fingertips, earlobes, or forehead. PPG signals can be readily acquired from devices such as smartphones, smartwatches, or web cameras. Classical machine learning techniques, such as decision trees, support vector machine (SVM), and k-nearest neighbor (kNN), have been proposed for PPG identification. We developed a UA classification method for smart devices using long short-term memory (LSTM). Specifically, our UA classifier algorithm uses raw signals so as not to lose the specific characteristics of the PPG signal coming from each user’s specific behavior. In the UA context, false positive and false negative rates are crucial. We recruited thirty healthy subjects and used a smartphone to take PPG data. Experimental results show that our Bi-LSTM-based UA algorithm based on the feature-based machine learning and raw data-based deep learning approaches provides 95.0% and 96.7% accuracy, respectively.
- 6 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 22 (14) , 14237-14249
A Biometric Authentication Technique Using Smartphone Fingertip Photoplethysmography Signals
Biometric Authentication (BA) is the process by which physiological measurements can be used to identify a specific person. BA has been implemented in various applications such as financial transactions, data privacy, and access control. Photoplethysmography (PPG) signals can be acquired from devices such as smartphones, smartwatches, or web cameras, which allow biometric signals to be readily captured. In this paper, we developed a BA classifier method for smart devices, which first reduces motion and noise artifacts (MNAs) in raw PPG signals, and then identifies subjects using the MNA-reduced PPG signals. Specifically, our BA classifier algorithm adopts an ensemble bagged trees (EBT) classifier with 16 PPG signal features from time and frequency domains. In the BA context, false positive (FP) and false negative (FN) rates are very important measurements to be considered. Acceptable FP and FN values were obtained. Experimental results show that our EBT-based BA algorithm achieved accuracy levels of 98.0% and 95.0%. Also, equal error rates (EER) measurements accomplished acceptable values of 2.42% and 5.90%.
- 6 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 22 (14) , 14237-14249
A Biometric Authentication Technique Using Smartphone Fingertip Photoplethysmography Signals
Biometric Authentication (BA) is the process by which physiological measurements can be used to identify a specific person. BA has been implemented in various applications such as financial transactions, data privacy, and access control. Photoplethysmography (PPG) signals can be acquired from devices such as smartphones, smartwatches, or web cameras, which allow biometric signals to be readily captured. In this paper, we developed a BA classifier method for smart devices, which first reduces motion and noise artifacts (MNAs) in raw PPG signals, and then identifies subjects using the MNA-reduced PPG signals. Specifically, our BA classifier algorithm adopts an ensemble bagged trees (EBT) classifier with 16 PPG signal features from time and frequency domains. In the BA context, false positive (FP) and false negative (FN) rates are very important measurements to be considered. Acceptable FP and FN values were obtained. Experimental results show that our EBT-based BA algorithm achieved accuracy levels of 98.0% and 95.0%. Also, equal error rates (EER) measurements accomplished acceptable values of 2.42% and 5.90%.