VTValerii V. Tairov

Valerii V. Tairov

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Valerii V. Tairov has a total of 43 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Comparative analysis of treatment of pulpal hyperemia

    by K. D. Kirsh, A. А. Adamchik, V. А. Ivashchenko, E. S. Zaporozhskaya-Abramova, S. Yu. Maksyukov, V. V. Tairov, I. A. Kovtun, I. V. Khromtsova, К. Д. Кирш, А. А. Адамчик, et al.

    INTRODUCTION. The leading problem of modern dentistry is the treatment of caries and its complications: diseases of the pulp and periapical tissues, and as a result, these pathologies in the adult population make up the basis of therapeutic procedures in the daily dental appointment of a practicing doctor. Currently, in order to provide an effective treatment method during conservative therapy with a diagnosis of pulp hyperemia, a dentist should clearly interpret the algorithm of therapeutic procedures and the means used. AIM. To improve the effectiveness of treating pulp hyperemia. MATERIALS AND METHODS. The study was conducted on the basis of the Kuban State Medical University Dental Polyclinic of the Russian Ministry of Health. This study was conducted with the approval of the Kuban State Medical University Ethical Committee, Protocol No. 125 dated September 12, 2023. A total of 127 patients with a diagnosis of pulp hyperemia (K04.0) and a chewing group of I-class teeth according to Black were observed. The patients were divided into 3 groups and 6 subgroups for the study. RESULTS. Among the patients examined, on the 30th day of the study, the Biodentine+Trigexylon method demonstrated a statistically significant advantage over the other two methods in terms of the frequency and intensity of complaints, especially in the subgroup of patients with tooth cavity opening. On the 180th day of observation, the Biodentine+Trigexylon method ensured complete absence of complaints in all patients, while in Groups 2 and 3, single complaints persisted in a small number of patients. By the end of the first year from the start of treatment, the Biodentine+Trigexylon method provided complete and stable relief of symptoms in all patients, regardless of whether the tooth pulp was exposed, while in Groups 2 and 3, there were occasional complaints related primarily to the subgroup with exposed pulp. CONCLUSION. The obtained data confirm that in the long-term period, all three methods provide a comparable objective result. This is consistent with scientific evidence on the choice of material for the treatment of deep caries and direct pulp coverage. However, the subjective outcome (absence of complaints) is achieved most reliably when using the combination Trigexylon+Biodentine.

  • Open Access

    Strength properties of rotating nickel-titanium endodontic instruments in terms of resistance to cyclic fatigue: A nonrandomized experimental study

    by A. A. Adamchik, В. В. Дорогань, V. V. Tairov, N. I. Bykova, E. S. Zaporozhskaya-Abramova, D. A. Stamov

    Background. Clinicians frequently encounter difficulties when selecting nickel-titanium instruments for specific clinical cases, primarily due to a lack of knowledge of what should be considered. Despite all the information available in the literature, the algorithm for making a decision is difficult to find. However, the bending angle and curvature radius of the root canal are known as essential factors to consider when diagnosing the anatomical and topographical features of tooth root canals during endodontic treatment. Objective. To evaluate the strength properties of rotating nickel-titanium endodontic instruments by conducting a comparative experimental study on their resistance to cyclic fatigue. Methods. A nonrandomized experimental study was conducted using two systems of rotating nickel-titanium instruments, the RM file (Rusmed, Russia) and ProTaper Universal (Dentsply Sirona, USA). Fusion 360 (Autodesk, USA) 3D modeling software was used to design root canal phantoms, which are blocks with a series of 5 channels for each instrument size, simulating a 45° root canal angle, a curvature radius of 5 mm, with a change in taper for each specific instrument, taking into account a magnification factor of 1.05. The following values were taken as the tip diameters for each instrument: S1 = 0.17 mm, S2 = 0.2 mm, F1 = 0.2 mm, F2 = 0.25 mm, F3 = 0.3 mm. Blocks with individual instrument sizes were made from metal using selective laser sintering. The blocks were fixed to a rigid canvas, and then the endodontic instruments under investigation were inserted through the canal openings along their entire length. Rotation was performed by an endomotor at a constant speed of 350 rpm, with a torque of 2.0 N/cm. Number of instrument cycles before failure was measured, recording the time of instrument failure. Next, surface wear of instrument fragments was studied using a JEOL JSM-7500F scanning electron microscope (Tokyo Boeki, Japan). The primary data base was created in Excel 2016 (Microsoft Corporation, USA). Hypothesis testing and sample comparison were performed using a JASP 0.19.1. open source software (JASP, Netherlands). Parametric criteria (Student’s t-test for independent samples) were used in the statistical data processing, and statistically significant differences were accepted at a level of p ≤ 0.05. Results. For the RM file system, S1 instrument showed an average number of rotation cycles of 292.00 ± 38.45, with a minimum value of 227 cycles and a maximum value of 340 cycles. S2 instrument demonstrated higher performance with an average value of 345.00 ± 62.72 cycles, ranging from 266 to 438 cycles. F1 instrument exhibited an average resistance of 256.00 ± 31.92 cycles, ranging from 188 to 291 cycles. The lowest values among the RM file instruments were recorded for F2 (111.00 ± 48.34 cycles, range 40–184) and F3 (82.00 ± 26.55 cycles, range 43–130). For the ProTaper Universal system, S1 instrument showed the highest performance with a mean of 395.00 ± 38.12 cycles, with a minimum of 306 cycles and a maximum of 450 cycles. S2 instrument of this system had an average durability of 170.00 ± 21.55 cycles with a range from 144 to 202 cycles. ProTaper Universal F-series instruments demonstrated relatively low performance: F1 had an average of 72.00 ± 10.75 cycles (58–91), F2 with a 86.00 ± 22.06 cycle (60–120), and F3 with a 79.00 ± 26.33 cycle (38–116). Conclusion. The data obtained demonstrate the advantage of the RM file system over ProTaper Universal in terms of resistance to cyclic fatigue. This system can be successfully used for treating complex root canals, including cases of pronounced curvature. Key factors in this case include using instruments within the manufacturer’s specified service life, maintaining optimal rotation speed, ensuring adequate irrigation, and controlling the force applied.

  • Open Access

    Morphological evaluation of the fibrin framework in the treatment of dental pulp hyperemia: experimental study

    by K. D. Kirsh, E. S. Zaporozhskaya-Abramova, A. А. Adamchik, V. А. Ivashchenko, V. V. Tairov, U. A. Dotdaeva, V. M. Starchenko

    INTRODUCTION. The complexity of the prognosis in the early and late stages of the conservative method of pulpitis treatment has limited its wide application. The article is aimed at studying and analyzing the potential of regenerative dentistry, which consists in restoring the function and structure of the dental pulp using innovative technologies. It is considered how biomaterials, fibrin framework (PRF) can be used to achieve this goal based on an experimental study and morphological assessment of the effect of these materials on the dental pulp. Platelet-rich fibrin (PRF) is a concentrate of platelets, which in recent years has become increasingly popular for regenerative procedures. An analysis of the materials used with appropriate conclusions is carried out.AIM. To conduct a comparative morphological assessment of the use of modern bioactive materials and fibrin (PRF) as a scaffold in the treatment of pulp hyperemia.MATERIALS AND METHODS. The experimental part of the study was performed on 8 white laboratory rats of 64 molars of teeth, Wistar lineage, of both sexes, with a body weight of 350–600 g, quarantined for at least 10–14 days, and kept in standard vivarium conditions of the Federal State Budgetary Educational Institution of Higher Medical Education of the Ministry of Health of the Russian Federation. The animals were divided into 4 groups – 2 individuals and 16 teeth in each group. Group 1 animals used fibrin (PRF) + “Trioxident” “Vladmiva”, Group 2 collagen membrane Geistlich Bio-Gide® + “Biodentine”, Group 3 fibrin (PRF) + “Biodentine” “Septodont”, Group 4 “Dycal” “Dentsply”. The experiment was conducted under anesthesia (protocol of the Ethics Committee of the Federal State Budgetary Educational Institution of Higher Education of the Ministry of Health of the Russian Federation No. 125 dated 09/12/2023). On the chewing surfaces of the 1 st and 2 nd molars, diamond carbide spherical borons were used to open the tooth cavity with partial pulp exposure. The formed cavity was treated with 0.05% chlorhexidine solution and dried. The test materials were then applied to the autopsy area. Experimental animals were removed from the experiment on days 3, 14, and 30. The resulting biological material was fixed in a 10% neutral formalin solution, decalcified, then poured into a histological medium and stained with hematoxylin and eosin according to Van Gieson. The sections were obtained on an Accu-Cut SRM 200 rotary microtome.RESULTS. In the course of an experimental study in group 1 using fibrin (PRF) + Trioxidant in the area of contact with the therapeutic material, activation of reactive and compensatory processes in the tooth pulp tissue was detected while maintaining its viability for 30 days, which indicated the most pronounced regenerative potential among all the studied groups. As a result of a morphological assessment of micro-preparations of pulp with direct coating with “Dycal” material, group 4 showed that on the 30th day the pathological process developed in the pulp is irreversible, because morphological changes were most pronounced: inflammatory infiltration with the presence of lymphocytes and neutrophils in the infiltrate, sclerotic changes, as well as granulation tissue and necrosis focus in the area of contact with the therapeutic material were noted.CONCLUSIONS. The results of an experimental study conducted to compare histological changes in the pulp state with the use of various groups of materials in the near and long-term follow-up periods showed that the combined use of bioactive materials and fibrin (PRF) for direct coating of pulp increases the effectiveness of dental treatment with diagnoses of pulp hyperemia, and is also a promising direction in regenerative dentistry, due to the high the potential to influence the stimulation of reparative processes in the tooth pulp.


  • Study of clinical efficacy of anticaries paste with hydroxyapatite and mummy

    by Zh.V. Solovyeva, A.A. Adamchik, E.S. Zaporozhskaya-Abramova, V.V. Tairov

    The personal choice of toothpaste largely determines the quality of hygiene and preventive measures. The large number of toothpastes on the market of the most diverse range of toothpastes makes the selection process difficult for the doctor and the patient. In this regard, the study of activity and effectiveness of therapeutic and preventive toothpastes is a prerequisite for the successful choice of personal oral hygiene products. The purpose. By means of enamel resistance test, acid biopsy and hygienic index to evaluate the prophylactic and remineralizing efficacy of «Anticaries paste with hydroxyapatite and mummy». Material and methods. During the clinical study 2 groups were created: main and control (25 people in each). Volunteers of the main group used «Anticaries paste with hydroxyapatite and mumiyo», in the control group – hygienic paste without active components. Results and discussion. Remineralization efficiency of the studied paste was 39–40 % according to the results of acid biopsy, TER-test – 36 %. Improvement of hygienic condition of the oral cavity during the observation period amounted to 50 %. Conclusions. It is established that “anti-caries paste with hydroxyapatite and mummy” has a pronounced remineralizing potential, contributes to the increase of resistance of hard tissues of teeth.


  • Open Access

    Experimental study of cyclic fatigue of nickel-titanium rotating endodontic instruments with controlled shape memory T C-Files Gold STEA (V ideya)

    by V. V. Tairov, А. А. Adamchik, E. Yu. Mendosa, L. А. Mamedova, M. D. Filippova, В. В. Дорогань, M. V. Savina

    INTRODUCTION. The dental market is constantly being replenished with new endodontic rotary instruments. Particular interest is drawn to the safety of using rotary files made in China from new nickel-titanium alloys with controlled memory wire (CM-Wire), which have undergone special treatment to enhance their elasticity and breakage resistance.AIM. Experimental evaluation of the cyclic fatigue resistance of new endodontic rotary instruments TC-Files Gold STEA (manufactured by VIDEYA, China), made from CM-Wire alloy, using models that simulate root canals of varying anatomical complexity depending on the angle of curvature and radius of root curvature.MATERIALS AND METHODS. Original models (patent application No. 2026183756) were used for testing, simulating three types of root canal curvatures: 45°, 90°, and an S-shaped curvature (450 and 600) with root curvature radii of 5 mm and 7 mm, respectively, and 5 mm and 3 mm for the S-shaped curvature. Nickeltitanium TC-files Gold STEA instruments of sizes 20/02, 15/03, 20/04, 25/04, 25/06, 30/04, 30/06, and 35/04 were sequentially fixed in the Geosoft Endoest endomotor. A total of 240 files were tested in the experiment, with 30 instruments of each size tested until breakage. The following parameters were set on the endomotor for all instruments: rotation speed of 250 RPM and torque of 3 N·cm. The files were inserted into a groove of the corresponding size, the endomotor was turned on, and the time until the instrument broke was recorded. The average time to breakage was calculated for each instrument size. Using a caliper, the length of the broken piece of each instrument was measured, and the average breakage length for each instrument size was determined. The number of cycles to breakage was also calculated. Statistical analysis of the obtained results was performed using multifactorial ANOVA in Statistica 13 software.RESULTS. The highest resistance to cyclic loads in the root canal models with a 45° curvature and a 5 mm radius of curvature was demonstrated by TC-files Gold STEA size 20/04. In the root canal models with a 90° curvature and a 7 mm radius of curvature, as well as with an S-shaped curvature at angles of 45° and 60° and radii of curvature of 5 mm and 3 mm, respectively, the TC-files Gold STEA size 15/03 showed the greatest resistance. The lowest resistance to cyclic loads in the root canal models with a 45° curvature and a 5 mm radius of curvature was observed in TC-files Gold STEA size 35/04. In the models with a 90° curvature and a 7 mm radius of curvature, the least resistance was found in TC-files Gold STEA size 30/06, while in the models with an S-shaped curvature at angles of 45° and 60° and radii of curvature of 5 mm and 3 mm, respectively, the least resistance was shown by TC-files Gold STEA size 30/04. For all instrument sizes, breakage occurred most quickly when rotating in S-shaped canals. For six of the eight sizes (TC-files Gold STEA sizes 20/02, 15/03, 25/04, 25/06, 30/04, and 35/04) produced by Videya, cyclic fatigue accumulated faster when the instruments were rotated in root canal models with a 45° curvature and a 5 mm radius of curvature, compared to the models with a 90° curvature and a 7 mm radius of curvature.CONCLUSIONS. The resistance of files made from CM-Wire alloys to cyclic fatigue depends on the size, taper, design of the instrument, and the anatomical complexity of the root canal. The risk of instrument breakage is highest in S-shaped root canal curvatures. In S-shaped canals (curvature of 45° with a radius of 5 mm and curvature of 60° with a radius of 3 mm), TC-files Gold STEA instruments with .04 and .06 tapers are not recommended. A root curvature of 45° with a 5 mm radius may be more dangerous for most sizes of CM-Wire alloy instruments than a 90° canal curvature with a 7 mm radius. Therefore, when diagnosing the complexity of root canal anatomy, both the angle of the root canal curvature and the radius of the curvature should be taken into account.

  • The Clinical Rationale for Using Thermo-Vibrational Impact on Composites in the Treatment of Dental Caries: A Randomized Clinical Trial

    by Anatoly A. Adamchik, Alexander A. Gushchin, Vladislav N. Samhaev, Ksenia D. Kirsh, Maria V. Adamchik, Ekaterina S. Zaporozhskaya-Abramova, Valery V. Tairov

  • A prospective analysis of the distribution of diseases of the oral mucosa in the “pre-covid” and COVID-19 periods

    by I.O. Kamishnikova, E.S. Zaporozhskaya-Abramova, A.A. Adamchik, V.V. Dorogan, V.V. Tairov, O.N. Risovannaya

    Over the past decades, cases of diseases of the oral mucosa (MSM) and the red border of the lips (RLB) have become significantly more frequent, and the severity of the course of diseases has increased markedly. Some diseases of SOP are prone to relapses, their treatment is not always successful. These diseases often lead to serious complications, including malignant ones. The outbreak of COVID-19 coronavirus infection was also one of the reasons that influenced the increase in the volume and variety of manifestations of MSM diseases. The purpose. To study the structure of MSM diseases in the “pre-epidemic” period and against the background of the pandemic of the new coronavirus infection COVID-19. Material and methods. The research was conducted on the basis of the therapeutic and prophylactic department of the clinic of the Federal State Budgetary Institution of the Ministry of Health of the Russian Federation. As part of the consultation, 988 patients with various diseases of MSM were examined from 2018 to 2022. The most common nosological forms of MSM diseases were identified. The patients were divided into 2 groups: group 1 – patients examined during the “pre-covid” period and group 2 – patients examined during the COVID-19 pandemic. All patients underwent the generally accepted methods of examination in the clinic (collection of complaints, anamnesis, examination of the litter, palpation). According to the indications, the presence of galvanism phenomena in the mouth (in the presence of orthopedic structures) was determined, bacterioscopic examination was performed and, in some cases, mainly for differential diagnosis, cytological examination and examination of the mucous membrane in the rays of a Wood lamp. Results and discussion. Analyzing the data obtained, we concluded that the overall increase in the number of patients who applied for MSM diseases in 2020-2022 increased the number of young patients aged 20 to 35 years. In the structure of diseases, the number of patients with such diseases as lichen planus (RLP), desquamative glossitis and glossalgia has increased. In the structure of dental lesions, cases of combined pathology of MSM diseases have become more frequent. Conclusions. In the complex of diagnostic studies of patients with MSM disease on the background of a coronavirus infection, in addition to a standard examination, it is necessary to introduce a general clinical examination by specialists such as a gastroenterologist, immunologist, neurologist, psychotherapist, dermatologist and others. Based on the etiology and clinic of MSM diseases in this category of patients, in addition to the prescribed generally accepted treatment regimens, it is necessary to prescribe drugs with effects on the autonomic and central nervous systems, as well as drugs that restore the intestinal and oral microflora.

  • Analysis of the efficiency of sound impact on the system of canals of the tooth root: A laboratory study

    by Anatolii A. Adamchik, Valerii V. Tairov, Irina O. Kamyshnikova, Ekaterina S. Zaporozhskaya-Abramova, Zhanna V. Solovyeva, Viktoria A. Ivashchenko, Natalia V. Lapina, Armenak Valer'Evich Arutyunov, Olga N. Risovannaya, Ksenia D. Kirsch, et al.

    BACKGROUND: The treatment of chronic apical periodontitis is directly related to the successful impact on the biofilm in the root canal system. Despite recent advances in understanding the effects of bacterial biofilm, there are still many questions concerning bacterial inactivation, and more research in these areas is needed. AIM: To investigate approaches to improve the effectiveness of treating chronic apical periodontitis by combining an antimicrobial drug with sound activation. MATERIALS AND METHODS: The biological material of 40 teeth was obtained as a result of removal according to guidelines to create a model of the process of obturation of a tooths root canal with a calcium hydroxide paste. In the main group, we used the EndoActivator (Dentsply Sirona, USA) system intracanally after introducing the resultant paste with the help of canal filler. The root canal filling was performed using canal filler in the comparison control group. The filling was assessed using a radiovisiograph (Schick Technologies Inc., USA), and the filling of macrocanal and microcanal of the tooth root was examined using a scanning electron microscope. RESULTS: The average score per tooth in the main group was 0.5 points/tooth. The average score per tooth in the control group was 2.05 points/tooth, which was significantly higher than in the main group (p 0.001). A comparison of the proportions of teeth with a certain number of points recorded in the compared groups revealed that teeth with a score of 0 (80%) predominated in the main group, whereas the proportion of such teeth in the control group was 15%; the differences are statistically significant (p 0.001). The data showed that the effectiveness of the root canal filling method with the canal filler and activation of the EndoActivator system resulted in the least complications. CONCLUSION: The use of sonic vibrations of the EndoActivator system causes a dynamic movement of the material in the root canal, aimed at improving its flow and distribution into the dentinal tubules, and contributes to the uniform homogeneity of the filling material in the lumen of the root canal and the absence of voids between the root filling and the walls of the root canal of the tooth.

  • Open Access

    Retrospective analysis of the quality of root canal filling according to the data of cone-beam computed tomography

    by A. A. Adamchik, В. В. Дорогань, E. S. Zaporozhskaya-Abramova, V. V. Tairov, V. A. Ivashchenko, K. D. Kirsh, S. A. Korovashkin

    Aim. Analysis of complications in the treatment of complicated caries.Materials and methods. Cone beam computed tomography results of 200 patients aged 21 to 64 years. The teeth were divided into frontal and chewing groups. The quality of the performed endodontic treatment was assessed.Results. During the analysis of the results of cone-beam computed tomography, the following complications of endodontic treatment were revealed: incomplete obturation of the root canal, removal of material beyond the apex of the tooth root, missed root canal, fracture of the instrument in the root canal. The regularity of their frequency was established, depending on the part of the jaw in which the tooth was located.Conclusions. Conducting cone-beam computed tomography during diagnosis, during treatment, will eliminate complicationsassociated with a lack of diagnostic imaging, effectively assess the success of the treatment for timely action.


  • Open Access

    Influence of thermal vibration impact on the strength characteristics of composite materials used in dentistry

    by A. A. Gushchin, A. A. Adamchik, S. P. Rubnikovich, E. S. Zaporozhskaya-Abramova, V. A. Ivashchenko, Zh. V. Solovyeva, V. V. Tairov, S. I. Risovannyi, Yu. L. Denisova

    The article discusses the evaluation of the effectiveness of the influence of thermal vibration effects on the bending strength and surface hardness of composite filling materials.The study was conducted on the basis of the Department of Therapeutic Dentistry of the Kuban State Medical University, as well as at the Krasnodar Instrument Plant “Cascade”. The samples under study were made according to the group affiliation from three different composite materials: Estelite Sigma Quick, Filtek Bulk Fill Posterior Restorative and DentLight. The bending strength was evaluated on the “MIP-10” testing machine of the company “NPK TECHMASH”. Determination of the surface hardness according to Vickers was carried out on the device PMT-3 of the company “LOMO”.According to laboratory studies, a statistically significant increase in flexural strength and surface hardness according to Vickers was determined for all samples of composite materials subjected to thermal vibration before polymerization.The data obtained indicate an increase in the strength characteristics of composite filling materials as a result of thermal vibration exposure before their polymerization, which increases the service life of composite fillings and reduces the risks of secondary caries formation after filling.