YDYing-Xue Dong

Ying-Xue Dong

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ying-Xue Dong has a total of 50 co-authors. Here are the top co-authors by number of shared publications:

  • Yun-Long Xia

    Department of Cardiology, The First Affiliated Hospital of Dalian Medical University, Dalian, China

    3 shared publications
  • Xia Yun-Long

    Department of Cardiology, The First Affiliated Hospital of Dalian Medical University, China

    2 shared publications
  • Yi-Heng Yang

    Department of Cardiology, The First Affiliated Hospital of Dalian Medical University, Dalian, China

    2 shared publications
  • Ying Chen

    Department of Cardiology The First Affiliated Hospital of Dalian Medical University Dalian China

    2 shared publications
  • Yunlong Xia

    Department of Cardiology, First Affiliated Hospital of Dalian Medical University, Dalian 116011, China

    2 shared publications
  • Ai Xin-Jing

    Department of Cardiology, The First Affiliated Hospital of Dalian Medical University, China

    1 shared publication

Latest Publications

  • Open Access

    Is conduction system pacing improving cardiac performance in patients with right bundle branch block and heart failure?

    by Jia Jing-Jing, Sun Xi-Xia, Li Tian-Zhu, Wang Xin, Yang Xiao-Lei, Ai Xin-Jing, Xia Yun-Long, Dong Ying-Xue

    Objective: The aim of this study was to evaluate the feasibility and safety of conduction system pacing (CSP) in patients with right bundle branch block (RBBB) and heart failure (HF). Methods: This retrospective study included all the patients with HF and a ventricular pacing frequency of more than 40% who underwent CSP between 2018 and 2023, with all enrolled patients presenting RBBB prior to the procedure. Clinical data, including echocardiographic and electrocardiographic findings, were collected before and after the procedure, with a minimum follow-up duration of 2 years. Results: CSP was successfully performed in 78 patients (78/88, 88.63%), comprising 13 patients (13/78, 16.67%) with His-bundle pacing (HBP) and 65 patients (65/78, 83.33%) with left bundle branch pacing (LBBP). Significant improvements were observed in QRS duration (148.06 ± 17.91 ms vs. 121.87 ± 14.47 ms, p < 0.001), left ventricular ejection fraction (LVEF) (43.79% ± 11.71% vs. 46.94% ± 10.06%, p = 0.020), left ventricular end-diastolic diameter (LVEDD) (54.15 ± 7.67 mm vs. 52.71 ± 7.67 mm, = 0.016), and the New York Heart Association (NYHA) functional class (2.97 ± 0.68 vs. 1.63 ± 1.08, p = 0.001). No significant change was noted in the left atrial diameter (LAD) (44.72 ± 8.07 mm vs. 43.86 ± 8.42 mm, p = 0.114). Subgroup analysis revealed that a marked LVEF improvement was observed in patients with baseline LVEF ≤35% (30.05% ± 2.76% vs. 41.42% ± 11.61%, p = 0.001). Logistic regression analysis revealed that LVEF (OR = 0.112, 95% CI: 0.011–0.839, and p = 0.001) and ΔQRS (OR = 1.449, 95% CI: 1.292–2.445, and p = 0.021) were independent predictors of echocardiographic response. Conclusion: CSP is safe and effective for patients with RBBB and HF, with particularly notable improvements in cardiac performance among those with severely reduced LVEF.


  • Open Access

    Feasibility and Safety of Atrioventricular Node Pacing in a Patient With Heart Failure and Atrioventricular Block

    by Guo-Cao Li, Wan-Xuan Ding, Shi-Yu Dai, Yi-Heng Yang, Wei Sun, Yun-Long Xia, Ying-Xue Dong

  • Mid‐Term Cardiac Outcomes in Prosthetic Valve Surgery and HF Patients Across EF After CSP

    by Peng Li, Xiao‐Xiao Jiang, Yi‐Heng Yang, Wan‐Xuan Ding, Ying Chen, Tian‐Zhu Li, Xiao‐Lei Yang, Yun‐Long Xia, Ying‐Xue Dong

    Objective: Clinical outcomes of conduction system pacing (CSP) in patients with prosthetic valve surgery (PVS) and heart failure (HF) remain unclear. This study evaluated the feasibility, safety, and clinical impact of CSP in this population. Methods: Consecutive patients with atrioventricular block post‐PVS and HF history undergoing CSP from January 2018 to December 2022 were enrolled. Exclusions included prior pacemaker implantation, biventricular pacing, or ventricular pacing p < 0.001; HFmrEF: 52.54 ± 5.01 vs. 56.73 ± 4.10 mm, p = 0.017; HFpEF: 48.07 ± 4.22 vs. 48.80 ± 3.99 mm, p = 0.035). The HFrEF cohort demonstrated significant improvements in LVEF (44.15 ± 12.23% vs. 31.26 ± 5.98%, p < 0.001), left atrial diameter (50.12 ± 13.91 vs. 54.00 ± 17.14 mm, p = 0.006), and New York Heart Association class (2.63 ± 0.85 vs. 3.13 ± 0.78, p = 0.002). No deterioration occurred in HFmrEF/HFpEF. Complete LVEF/LVEDD normalization was achieved in 26.47% of HFrEF patients (9/34), with absence of rheumatic heart disease (RHD) as an independent predictor (HR = 8.851, 95% CI 1.336–58.646, p = 0.024). Over 25.49 ± 9.4 months, no cardiac perforation, thrombosis, pacemaker‐induced cardiomyopathy (PICM), or infections occurred. Conclusions: CSP is feasible and safe, promoting cardiac reverse remodeling and mitigating PICM risk in PVS patients with HF across LVEF categories. Over 25% of HFrEF patients achieved complete normalization, predicted by non‐RHD etiology.


  • Open Access

    Current Advance, Challenges and Future Perspectives of Conduction System Pacing

    by Tong-Yu Wang, Pei-Pei Ma, Yi-Heng Yang, Yun-Long Xia, Zhao-Meng Jing, Zhuang-Chuan She, Ying-Xue Dong

    Existing techniques for pacing the right ventricle and providing cardiac resynchronization therapy through biventricular pacing are not effective in restoring damage to the conduction system. Therefore, the need for new pacing modalities and techniques with more sensible designs and algorithms is justified. Although the benefits of conduction system pacing (CSP), which mainly include His bundle pacing (HBP) and left bundle branch area pacing (LBBAP), are evident in patients who require conduction system recuperation, the critical criteria for left CSP remain unclear, and the roles of different pacing modalities of CSP for cardiac resynchronization are not definite. In this review, we aimed to highlight the advantages of different CSP options, current advancement in the surgical devices, and future directions.


  • Open Access

    Is conduction system pacing more effective than right ventricular pacing in reducing atrial high-rate episodes in patients with heart failure and preserved ejection fraction?

    by Ying Chen, Zhu-Lin Ma, Fei Liu, Nan Wang, Yue-Yang Ma, Zi-An Guan, Zhuang-Chuan Zhe, Yun-Long Xia, Ying-Xue Dong

    Background: The relationship between conduction system pacing (CSP) and the incidence of atrial fibrillation (AF) in patients with heart failure and preserved ejection fraction (HFpEF) remains uncertain. This study aims to investigate the occurrence of atrial high-rate episodes (AHREs) following CSP in patients with HFpEF, in comparison to right ventricular pacing (RVP).Methods: Patients with HFpEF who received dual-chamber pacemakers for atrioventricular block were retrospectively enrolled from January 2018 to January 2023. Both new-onset and progressive AHREs were recorded, along with other clinical data, including cardiac performance and lead outcomes.Results: A total of 498 patients were enrolled, comprising 387 patients with RVP and 111 patients with CSP, with a follow-up duration of 44.42 ± 10.41 months. In patients without a prior history of AF, CSP was associated with a significantly lower incidence of new-onset AHREs when the percentage of ventricular pacing was ≥20% (9.52% vs. 29.70%, P = 0.001). After adjusting for confounding factors, CSP exhibited a lower hazard ratio for new-onset AHREs compared to RVP (HR 0.336; [95% CI: 0.142–0.795]; P = 0.013), alongside left atrial diameter (LAD) (HR 1.109; [95% CI: 1.048–1.173]; P < 0.001). In patients with a history of AF, the progression of AHREs in CSP and RVP did not differ significantly (32.35% vs. 34.75%, P = 0.791). Cardiac performance metrics, including left ventricular end-diastolic diameter (LVEDD) (49.09 ± 4.28 mm vs. 48.08 ± 4.72 mm; P = 0.015), LAD (40.68 ± 5.49 mm vs. 39.47 ± 5.24 mm; P = 0.001), and NYHA class (2.31 ± 0.46 vs. 1.59 ± 0.73; P < 0.001), improved obviously following CSP, while LVEDD (48.37 ± 4.57 mm vs. 49.30 ± 5.32 mm; P < 0.001), LAD (39.77 ± 4.58 mm vs. 40.83 ± 4.80 mm; P < 0.001), NYHA class (2.24 ± 0.43 vs. 2.35 ± 0.83; P = 0.018), and left ventricular ejection fraction (LVEF) (57.41 ± 2.42 vs. 54.24 ± 6.65; P < 0.001) deteriorated after RVP.Conclusion: Our findings suggest that CSP may be associated with improvements in cardiac performance and a reduction in new-onset AHREs compared to RVP in patients with HFpEF. However, prospective randomized trials are anticipated to confirm these potential benefits.


  • Open Access

    Conduction system pacing upgrade versus biventricular pacing on pacemaker-induced cardiomyopathy: a retrospective observational study

    by Ma Pei-Pei, Chen Ying, Yang Yi-Heng, Li Guo-Cao, Ma Cheng-Ming, Fa Qing, Gao Lian-Jun, Xia Yun-Long, Dong Ying-Xue

    Objective: The feasibility of the conduction system pacing (CSP) upgrade as an alternative modality to the traditional biventricular pacing (BiVP) upgrade in patients with pacemaker-induced cardiomyopathy (PICM) remains uncertain. This study sought to compare two modalities of CSP (His bundle pacing (HBP) and left bundle branch pacing (LBBP)) with BiVP and no upgrades in patients with pacing-induced cardiomyopathy.Methods: This retrospective analysis comprised consecutive patients who underwent either BiVP or CSP upgrade for PICM at the cardiac department from 2017 to 2021. Patients with a follow-up period exceeding 12 months were considered for the final analysis.Results: The final group of patients who underwent upgrades included 48 individuals: 11 with BiVP upgrades, 24 with HBP upgrades, and 13 with LBBP upgrades. Compared to the baseline data, there were significant improvements in cardiac performance at the last follow-up. After the upgrade, the QRS duration (127.81 ± 31.89 vs 177.08 ± 34.35 ms, p < 0.001), NYHA class (2.28 ± 0.70 vs 3.04 ± 0.54, p < 0.05), left ventricular end-diastolic diameter (LVEDD) (54.08 ± 4.80 vs 57.50 ± 4.85 mm, p < 0.05), and left ventricular ejection fraction (LVEF) (44.46% ± 6.39% vs 33.15% ± 5.25%, p < 0.001) were improved. There was a noticeable improvement in LVEF in the CSP group (32.15% ± 3.22% vs 44.95% ± 3.99% (p < 0.001)) and the BiVP group (33.90% ± 3.09% vs 40.83% ± 2.99% (p < 0.001)). The changes in QRS duration were more evident in CSP than in BiVP (56.65 ± 11.71 vs 34.67 ± 13.32, p < 0.001). Similarly, the changes in LVEF (12.8 ± 3.66 vs 6.93 ± 3.04, p < 0.001) and LVEDD (5.80 ± 1.71 vs 3.16 ± 1.35, p < 0.001) were greater in CSP than in BiVP. The changes in LVEDD (p = 0.549) and LVEF (p = 0.570) were similar in the LBBP and HBP groups. The threshold in LBBP was also lower than that in HBP (1.01 ± 0.43 vs 1.33 ± 0.32 V, p = 0.019).Conclusion: The improvement of clinical outcomes in CSP was more significant than in BiVP. CSP may be an alternative therapy to CRT for patients with PICM. LBBP would be a better choice than HBP due to its lower thresholds.


  • Open Access

    Comparison of Upgrading to Conduction System Pacing and Biventricular Pacing in Patients with Pacemaker-induced Cardiomyopathy

    by Ying Chen, Peipei Ma, Yiheng Yang, Guocao Li, Chengming Ma, Qing Fa, Lianjun Gao, Yunlong Xia, Yingxue Dong

    Background: Pacemaker-induced cardiomyopathy (PICM) is common in patients with right ventricular pacing (RVP). We are still not clear whether the conduction system pacing (CSP) upgrade is better than the traditional biventricular pacing (BiVP) upgrade. Objective: To illustrate the performances of different upgrade modalities in patients with PICM. Methods: All patients with PICM were consecutively enrolled and followed for at least one year regardless of resynchronization upgrade from 2017 to 2021. Clinical data, including echocardiographic parameters, electrocardiogram measurements and cardiac function, were collected and compared. Results: A total of 73 patients were enrolled. Forty-eight patients had a resynchronization upgrade including 11 patients with BiVP, 24 patients with HBP and 13 patients with LBBP. The QRS duration (127.81±31.89 vs. 177.08±34.35ms, PPPPPPPP=0.019). Conclusion: The improvement of clinical outcomes in CSP were more significant than in BiVP. CSP may be an alternative therapy of CRT in patients with PICM. LBBP would be a better choice for achieving lower thresholds compared with HBP.

  • Open Access

    A Case Report of a Wenckebach Phenomenon Occurring during a His-Bundle Pacing Procedure: Is It Atrioventricular Node Pacing?

    by Chengming Ma, Wenwen Li, Yongmei Cha, Yunlong Xia, Lianjun Gao, Yingxue Dong

    A 70-year-old man with severe valvular cardiomyopathy, permanent atrial fibrillation (AF) with a slow ventricular response, and transient atrioventricular (AV) block, was admitted to our center for severe heart failure and recurrent presyncope. While hospitalized, the coronary computed tomography angiography (CTA) showed huge atriums. We tried His bundle pacing (HBP). HB potential was observed at site A, and the His-ventricular (HV) interval was 68 ms. The duration from the stimulus signal to the onset of paced QRS (S-QRSonset) at site A was 232 ms when pacing at 60 beats per minute (BPM) with the pacing threshold of 2.0 V/0.5 ms. The S-QRSonset was longer than the HV interval and had a notable and progressive prolongation from 252 ms to 456 ms during the pacing at 90 BPM. Then, we pushed another lead a little forward, and the S-QRSonset shortened back to 68 ms, and the paced QRS morphology was the same as the intrinsic QRS morphology with the pacing threshold of 1.5 V/0.5 ms. The progressively prolonged S-QRSonset demonstrated a Wenckebach phenomenon (WP), a well-known electrophysiological characteristic of the AV node (AVN). It is the first time to report an intraoperative AVN-pacing related-WP in a patient with persistent AF. The enlarged atrium might be convenient for capturing the AVN. There are some other potential explanations for this phenomenon. The diameters of atriums decreased significantly, and the symptoms improved after the procedure. This is the first reported case in which we might achieve AVN capture in a patient with persistent AF. Although we ultimately chose HBP for better long-term pacing thresholds, the result of this case suggested that AVN pacing may be possible.