Zhengqi Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Zhengqi Li has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Zhichao Chen
School of Energy Science and Engineering, Harbin Institute of Technology, 92, West Dazhi Street, Harbin, 150001, PR China
5 shared publications Qunyi Zhu
School of Energy Science and Engineering, Harbin Institute of Technology, 92, West Dazhi Street, Harbin 150001, PR China
3 shared publications- Guangkui Liu
China Special Equipment Inspection and Research Institute, Beijing 100029, China
2 shared publications - Lingyan Zeng
School of Energy Science and Engineering, Harbin Institute of Technology, Harbin, China
2 shared publications - Min Kuang
Ningbo University
2 shared publications - Pengfei Yang
Neurovascular Center, Changhai Hospital, Naval Medical University, Shanghai, China
2 shared publications
Latest Publications
- 1 April 2023
- Published by Elsevier in Structures
- Vol. 51, 1821-1832
Analytical study on influence of subsurface voids on moment capacity of singly reinforced concrete beam – Inspired by a project case study
- 1 April 2023
- Published by Elsevier in Structures
- Vol. 51, 1821-1832
Analytical study on influence of subsurface voids on moment capacity of singly reinforced concrete beam – Inspired by a project case study
- 31 August 2018
- Published by ASTM International in Journal of Testing and Evaluation
- Vol. 48 (2) , 1319-1333
In-Place Estimation of Concrete Compressive Strength Using Postinstalled Pullout Test – A Case Study
It was proposed that a 16-story steel framing structure be built on top of an existing 12-year-old 1-story reinforced-concrete structure. The in-place concrete compressive strength of 3 footings and 29 plinths was estimated using a postinstalled pullout test and a core compressive strength test. The influence of different length-to-diameter ratios of the cores and different diameters of cores and the correlation between maximum pullout force and core compressive strength were investigated. The results of the pullout test and core strength test indicate that the concrete compressive strength of footings and plinths was considered structurally adequate as per the acceptance criteria for tested core strength and estimated core strength given by ACI 318, Building Code Requirements for Structural Concrete and Commentary, and ACI 228.1R, In-Place Methods to Estimate Concrete Strength, respectively. Maximum pullout force had a strong correlation with the core compressive strength. The influence of the different length-to-diameter ratio of cores on the strength correlation was not significant if the raw results of the compressive strength tests were corrected by multiplying the corresponding correction factors for the length-to-diameter ratio given by ASTM C42, Standard Test Method for Obtaining and Testing Drilled Cores and Sawed Beams of Concrete. The mixed use of the test results of 3.20 and 3.74-in. (81-mm and 95-mm) cores resulted in a decrease in the R2 of the correlation model, compared to that of the correlation model based on 3.74-in. (95-mm) cores. This was attributed to the potentially increased testing error as the diameter of the cores decreased. Recommendations for successfully performing postinstalled pullout tests in the field were proposed. With the use of pullout tests, the project team was able to determine that the existing structural members had sufficient capacity. A delay in the project schedule was avoided.
- 31 August 2018
- Published by ASTM International in Journal of Testing and Evaluation
- Vol. 48 (2) , 1319-1333
In-Place Estimation of Concrete Compressive Strength Using Postinstalled Pullout Test – A Case Study
It was proposed that a 16-story steel framing structure be built on top of an existing 12-year-old 1-story reinforced-concrete structure. The in-place concrete compressive strength of 3 footings and 29 plinths was estimated using a postinstalled pullout test and a core compressive strength test. The influence of different length-to-diameter ratios of the cores and different diameters of cores and the correlation between maximum pullout force and core compressive strength were investigated. The results of the pullout test and core strength test indicate that the concrete compressive strength of footings and plinths was considered structurally adequate as per the acceptance criteria for tested core strength and estimated core strength given by ACI 318, Building Code Requirements for Structural Concrete and Commentary, and ACI 228.1R, In-Place Methods to Estimate Concrete Strength, respectively. Maximum pullout force had a strong correlation with the core compressive strength. The influence of the different length-to-diameter ratio of cores on the strength correlation was not significant if the raw results of the compressive strength tests were corrected by multiplying the corresponding correction factors for the length-to-diameter ratio given by ASTM C42, Standard Test Method for Obtaining and Testing Drilled Cores and Sawed Beams of Concrete. The mixed use of the test results of 3.20 and 3.74-in. (81-mm and 95-mm) cores resulted in a decrease in the R2 of the correlation model, compared to that of the correlation model based on 3.74-in. (95-mm) cores. This was attributed to the potentially increased testing error as the diameter of the cores decreased. Recommendations for successfully performing postinstalled pullout tests in the field were proposed. With the use of pullout tests, the project team was able to determine that the existing structural members had sufficient capacity. A delay in the project schedule was avoided.
- Open Access
- 30 June 2017
- Published by Editorial CSIC in Materiales de Construcción
- Vol. 67 (326) , e119
Predicting the drying shrinkage behavior of high strength portland cement mortar under the combined influence of fine aggregate and steel micro fiber
The workability, 28-day compressive strength and free drying shrinkage of a very high strength (121-142 MPa) steel micro fiber reinforced portland cement mortar were studied under a combined influence of fine aggregate content and fiber content. The test results showed that an increase in the fine aggregate content resulted in decreases in the workability, 28-day compressive strength and drying shrinkage of mortar at a fixed fiber content. An increase in the fiber content resulted in decreases in the workability and drying shrinkage of mortar, but an increase in the 28-day compressive strength of mortar at a fixed fine aggregate content. The modified Gardner model most accurately predicted the drying shrinkage development of the high strength mortars, followed by the Ross model and the ACI 209R-92 model. The Gardner model gave the least accurate prediction for it was developed based on a database of normal strength concrete.
- 30 June 2017
- Published by Editorial CSIC in Materiales de Construcción
- Vol. 67 (326) , e119
Open AccessPredicting the drying shrinkage behavior of high strength portland cement mortar under the combined influence of fine aggregate and steel micro fiber
The workability, 28-day compressive strength and free drying shrinkage of a very high strength (121-142 MPa) steel micro fiber reinforced portland cement mortar were studied under a combined influence of fine aggregate content and fiber content. The test results showed that an increase in the fine aggregate content resulted in decreases in the workability, 28-day compressive strength and drying shrinkage of mortar at a fixed fiber content. An increase in the fiber content resulted in decreases in the workability and drying shrinkage of mortar, but an increase in the 28-day compressive strength of mortar at a fixed fine aggregate content. The modified Gardner model most accurately predicted the drying shrinkage development of the high strength mortars, followed by the Ross model and the ACI 209R-92 model. The Gardner model gave the least accurate prediction for it was developed based on a database of normal strength concrete.
- 1 December 2015
- Published by Elsevier in Construction and Building Materials
- Vol. 100, 225-233
Influence of silica flour–silica fume combination on the properties of high performance cementitious mixtures at ambient temperature curing
- 1 December 2015
- Published by Elsevier in Construction and Building Materials
- Vol. 100, 225-233
Influence of silica flour–silica fume combination on the properties of high performance cementitious mixtures at ambient temperature curing
- 10 March 2011
- Published by American Chemical Society (ACS) in Energy & Fuels
- Vol. 25 (4) , 1485-1496
Staged-Air Ratio Optimization for a New Down-Fired Technology within a Cold Small-Scale Model of a 350 MWe Utility Boiler
- 10 March 2011
- Published by American Chemical Society (ACS) in Energy & Fuels
- Vol. 25 (4) , 1485-1496
Staged-Air Ratio Optimization for a New Down-Fired Technology within a Cold Small-Scale Model of a 350 MWe Utility Boiler