Patricio Guerrero
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Patricio Guerrero has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
- Wim Dewulf
KU Leuven
6 shared publications Wim Dewulf
4 shared publications- Simon Bellens
Department of Mechanical Engineering, KU Leuven, Leuven, Belgium
3 shared publications - Eduardo Xavier Miqueles
Brazilian Synchrotron Light Laboratory, CNPEM, Campinas, SP, Brazil
2 shared publications Matheus Bernardi
Brazilian Synchrotron Light Laboratory National Center for Research in Energy and Materials Campinas Brazil
2 shared publications- Negin Khoeiniha
Mechanical Engineering, KU Leuven, Leuven, Belgium
2 shared publications
Latest Publications
- 4 October 2025
- Published by Springer Nature in Journal of Nondestructive Evaluation
- Vol. 44 (4) , 1-19
Bayesian Uncertainty Quantification and Regularized Reconstruction for CT-Based Dimensional Metrology
- 4 October 2025
- Published by Springer Nature in Journal of Nondestructive Evaluation
- Vol. 44 (4) , 1-19
Bayesian Uncertainty Quantification and Regularized Reconstruction for CT-Based Dimensional Metrology
- Open Access
- 2 July 2025
- Published by Elsevier in CIRP Journal of Manufacturing Science and Technology
- Vol. 61, 336-352
Towards industrially relevant total variation based reconstruction of few-view computed tomography by exploiting noise level estimation
- 2 July 2025
- Published by Elsevier in CIRP Journal of Manufacturing Science and Technology
- Vol. 61, 336-352
Open AccessTowards industrially relevant total variation based reconstruction of few-view computed tomography by exploiting noise level estimation
- Open Access
- 1 February 2025
- Published by NDT.net GmbH & Co. KG in e-Journal of Nondestructive Testing
- Vol. 30 (2)
Uncertainty quantification of CT regularized reconstruction within the Bayesian framework
Computed Tomography (CT) reconstruction is an important inverse problem in industrial imaging, requiring robust methods to address different sources of error in the data and model. Among the various reconstruction approaches that tackle different challenges in CT modeling [1], such as limitations in the data, statistical methods are known for their ability to model various properties [2, 3] of the input data and assess their impact on the reconstruction outcome [4]. These methods can also incorporate regularization techniques, which, for instance, force smoothness in the solution by penalizing heavy oscillations in pixel values. Given our interest in the uncertainty Quantification (UQ) of CT reconstruction, we employ statistical methods within the Bayesian framework for solving this inverse problem. First, we define a model for CT reconstruction and formulate a statistical framework for the problem. We then reconstruct our data using appropriate methods and quantify the uncertainty in the results. Our primary focus is on the effect of noise on the reconstruction and the corresponding uncertainty it induces. Additionally, we aim to utilize computationally feasible sampling techniques to analyze the distribution of the solution, enabling an in-depth evaluation of the results. To achieve these goals, we apply a rapid regularized Markov Chain Monte Carlo (MCMC) reconstruction method [4, 5], employing the Metropolis-Adjusted Langevin Algorithm (MALA) [6] and its Lipschitz-adaptive variant (LipMALA) [7]. This approach produces a volumetric model where each voxel is represented by a probability distribution, which can be transformed into a triplet of gray-value models: one for the central value and two for the bounds of the confidence interval. Bi-directional and uni-directional length measurements derived from these gray-value models applied to real CT data yield task-specific measurement uncertainties. This method significantly reduces computational and storage demands compared to classic Monte Carlo simulations while incorporating regularization techniques. Experimental results using aluminum cylindrical step gauge [8] data acquired with a Nikon 225 CT system validate our approach. This work provides a scalable, statistically grounded methodology for UQ in CT reconstruction, offering enhanced reliability for industrial applications.
- 1 February 2025
- Published by NDT.net GmbH & Co. KG in e-Journal of Nondestructive Testing
- Vol. 30 (2)
Open AccessUncertainty quantification of CT regularized reconstruction within the Bayesian framework
Computed Tomography (CT) reconstruction is an important inverse problem in industrial imaging, requiring robust methods to address different sources of error in the data and model. Among the various reconstruction approaches that tackle different challenges in CT modeling [1], such as limitations in the data, statistical methods are known for their ability to model various properties [2, 3] of the input data and assess their impact on the reconstruction outcome [4]. These methods can also incorporate regularization techniques, which, for instance, force smoothness in the solution by penalizing heavy oscillations in pixel values. Given our interest in the uncertainty Quantification (UQ) of CT reconstruction, we employ statistical methods within the Bayesian framework for solving this inverse problem. First, we define a model for CT reconstruction and formulate a statistical framework for the problem. We then reconstruct our data using appropriate methods and quantify the uncertainty in the results. Our primary focus is on the effect of noise on the reconstruction and the corresponding uncertainty it induces. Additionally, we aim to utilize computationally feasible sampling techniques to analyze the distribution of the solution, enabling an in-depth evaluation of the results. To achieve these goals, we apply a rapid regularized Markov Chain Monte Carlo (MCMC) reconstruction method [4, 5], employing the Metropolis-Adjusted Langevin Algorithm (MALA) [6] and its Lipschitz-adaptive variant (LipMALA) [7]. This approach produces a volumetric model where each voxel is represented by a probability distribution, which can be transformed into a triplet of gray-value models: one for the central value and two for the bounds of the confidence interval. Bi-directional and uni-directional length measurements derived from these gray-value models applied to real CT data yield task-specific measurement uncertainties. This method significantly reduces computational and storage demands compared to classic Monte Carlo simulations while incorporating regularization techniques. Experimental results using aluminum cylindrical step gauge [8] data acquired with a Nikon 225 CT system validate our approach. This work provides a scalable, statistically grounded methodology for UQ in CT reconstruction, offering enhanced reliability for industrial applications.
- Open Access
FISTA-Condat-Vu: Automatic Differentiation for Hyperparameter Learning in Variational Models
Motivated by industrial computed tomography, we propose a memory efficient strategy to estimate the regularization hyperparameter of a non-smooth variational model. The approach is based on a combination of FISTA and Condat-Vu algorithms exploiting the convergence rate of the former and the low per-iteration complexity of the latter. The estimation is cast as a bilevel learning problem where a first-order method is obtained via reduced-memory automatic differentiation to compute the derivatives. The method is validated with experimental industrial tomographic data with the numerical implementation available.
Open AccessFISTA-Condat-Vu: Automatic Differentiation for Hyperparameter Learning in Variational Models
Motivated by industrial computed tomography, we propose a memory efficient strategy to estimate the regularization hyperparameter of a non-smooth variational model. The approach is based on a combination of FISTA and Condat-Vu algorithms exploiting the convergence rate of the former and the low per-iteration complexity of the latter. The estimation is cast as a bilevel learning problem where a first-order method is obtained via reduced-memory automatic differentiation to compute the derivatives. The method is validated with experimental industrial tomographic data with the numerical implementation available.
- 2 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Computational Imaging
- Vol. 10 (25730436) , 700-712
Automatic and Computationally Efficient Alignment in Fan- and Cone-Beam Tomography
This work is concerned with fan- and cone-beam computed tomography with circular source trajectory, where the reconstruction inverse problem requires an accurate knowledge of source, detector and rotational axis relative positions and orientations. We address this additional inverse problem as a preceding step of the reconstruction process directly from the acquired projections. In the cone-beam case, we present a method that estimates both the detector shift (orthogonal to both focal and rotational axes) and the in-plane detector rotation (over the focal axis) based on the variable projection optimization approach. In addition and for the fan-beam case, two new strategies with low computational cost are presented to estimate the detector shift based on a fan-beam symmetry condition. The methods are validated with simulated and experimental industrial tomographic data with code examples available for both fan- and cone-beam geometries.
- 2 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Computational Imaging
- Vol. 10 (25730436) , 700-712
Automatic and Computationally Efficient Alignment in Fan- and Cone-Beam Tomography
This work is concerned with fan- and cone-beam computed tomography with circular source trajectory, where the reconstruction inverse problem requires an accurate knowledge of source, detector and rotational axis relative positions and orientations. We address this additional inverse problem as a preceding step of the reconstruction process directly from the acquired projections. In the cone-beam case, we present a method that estimates both the detector shift (orthogonal to both focal and rotational axes) and the in-plane detector rotation (over the focal axis) based on the variable projection optimization approach. In addition and for the fan-beam case, two new strategies with low computational cost are presented to estimate the detector shift based on a fan-beam symmetry condition. The methods are validated with simulated and experimental industrial tomographic data with code examples available for both fan- and cone-beam geometries.
- Open Access
- 1 March 2024
- Published by NDT.net GmbH & Co. KG in e-Journal of Nondestructive Testing
- Vol. 29 (3)
The constrained split Bregman algorithm for enhancing the quality of image reconstruction and analysis in few-view computed tomography
Decreasing the scanning time by limiting the number of projection images taken in in-line computed tomography (CT) increases the ill-posedness of the algebraic reconstruction problem. Reformulating the few-view CT reconstruction problem to the total varia....
- 1 March 2024
- Published by NDT.net GmbH & Co. KG in e-Journal of Nondestructive Testing
- Vol. 29 (3)
Open AccessThe constrained split Bregman algorithm for enhancing the quality of image reconstruction and analysis in few-view computed tomography
Decreasing the scanning time by limiting the number of projection images taken in in-line computed tomography (CT) increases the ill-posedness of the algebraic reconstruction problem. Reformulating the few-view CT reconstruction problem to the total varia....
- 29 February 2024
- Published by Elsevier in Precision Engineering
- Vol. 88, 449-463
Machine learning based sinogram interpolation for X-ray computed tomography validated on experimental data
- 29 February 2024
- Published by Elsevier in Precision Engineering
- Vol. 88, 449-463
Machine learning based sinogram interpolation for X-ray computed tomography validated on experimental data
- 24 January 2024
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 35 (4) , 046004
Direct voxel classification from x-ray projections for 3D pore detection applied to laser sintered parts
X-ray computed tomography (XCT) is a validated and frequently used tool to verify part geometry and to perform a non-destructive inspection of additive manufacturing parts. However, the acquisition of a large number of x-ray projections generates long inspection times. This conflicts with a high throughput of the production process and hinders the integration of XCT as an in-line quality control procedure for low-end parts. In this paper, we propose a method to obtain three-dimensional (3D) information of the internal pores from a limited view or limited angle scan. The method combines a forward projection model of a cone-beam x-ray system and a deep learning neural network to directly classify each individual voxel, based on the x-ray projections in order to avoid the reconstruction and segmentation step. Accompanying reconstruction artifacts for limited view and limited angle XCT scans are thereby reduced, while preserving 3D information of the pores, defects or inclusions inside the material. The method is validated on real x-ray projections of polymer laser sintered industrial parts and shows a significant reduction in the required x-ray projections, hence acquisition time.
- 24 January 2024
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 35 (4) , 046004
Direct voxel classification from x-ray projections for 3D pore detection applied to laser sintered parts
X-ray computed tomography (XCT) is a validated and frequently used tool to verify part geometry and to perform a non-destructive inspection of additive manufacturing parts. However, the acquisition of a large number of x-ray projections generates long inspection times. This conflicts with a high throughput of the production process and hinders the integration of XCT as an in-line quality control procedure for low-end parts. In this paper, we propose a method to obtain three-dimensional (3D) information of the internal pores from a limited view or limited angle scan. The method combines a forward projection model of a cone-beam x-ray system and a deep learning neural network to directly classify each individual voxel, based on the x-ray projections in order to avoid the reconstruction and segmentation step. Accompanying reconstruction artifacts for limited view and limited angle XCT scans are thereby reduced, while preserving 3D information of the pores, defects or inclusions inside the material. The method is validated on real x-ray projections of polymer laser sintered industrial parts and shows a significant reduction in the required x-ray projections, hence acquisition time.
- Open Access
Automatic alignment in cone-beam tomography via fan-beam symmetry and variable projection
This work is concerned with cone-beam computed tomography with circular source trajectory, where the reconstruction inverse problem requires an accurate knowledge of source, detector and rotational axis relative positions and orientations. We address this problem as a preceding step of the reconstruction process directly from the acquired projections. The method estimates both the detector shift (orthogonal to focal and rotational axes) and the in-plane detector rotation, relative to source and rotational axis. The obtained algorithm is based on a fan-beam symmetry condition and the variable projection optimization approach with a low computational cost. Therefore, the alignment problem for fan-beam tomography is addressed as well. The methods are validated with simulated and real industrial tomographic data with code examples available for both fan- and cone-beam geometries.
Open AccessAutomatic alignment in cone-beam tomography via fan-beam symmetry and variable projection
This work is concerned with cone-beam computed tomography with circular source trajectory, where the reconstruction inverse problem requires an accurate knowledge of source, detector and rotational axis relative positions and orientations. We address this problem as a preceding step of the reconstruction process directly from the acquired projections. The method estimates both the detector shift (orthogonal to focal and rotational axes) and the in-plane detector rotation, relative to source and rotational axis. The obtained algorithm is based on a fan-beam symmetry condition and the variable projection optimization approach with a low computational cost. Therefore, the alignment problem for fan-beam tomography is addressed as well. The methods are validated with simulated and real industrial tomographic data with code examples available for both fan- and cone-beam geometries.
- Open Access
Alternative Fan-beam Backprojection and Adjoint Operators
We present in this work alternative analytic formulations for the fan-beam tomographic backprojection operation and its associated adjoint transform in standard (equiangular) and linear (equidistant) detector geometries. The proposed formulations are obtained from a recent backprojection theorem in parallel tomography. Such formulations are written as a Bessel-Neumann series in the frequency domain that can be implemented as an $O(N^{2.3729})$ matrix multiplication. Proofs are provided together with numerical simulations compared with conventional fan-beam $O(N^{3})$ backprojection representations showing more robustness when dealing with highly noisy data.Open AccessAlternative Fan-beam Backprojection and Adjoint Operators
We present in this work alternative analytic formulations for the fan-beam tomographic backprojection operation and its associated adjoint transform in standard (equiangular) and linear (equidistant) detector geometries. The proposed formulations are obtained from a recent backprojection theorem in parallel tomography. Such formulations are written as a Bessel-Neumann series in the frequency domain that can be implemented as an $O(N^{2.3729})$ matrix multiplication. Proofs are provided together with numerical simulations compared with conventional fan-beam $O(N^{3})$ backprojection representations showing more robustness when dealing with highly noisy data.