Mahitosh Banafer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Mahitosh Banafer has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Soumya Ranjan Mohanty
Electrical Engineering Department, Indian Institute of Technology (BHU), Varanasi, India
4 shared publications Soumya R. Mohanty
1 shared publication- Tapan Prakash
School of Electrical Engineering, Vellore Institute of Technology, Vellore, India
1 shared publication - Vivek Kumar
National Institute of Technology Sikkim
1 shared publication
Latest Publications
- 30 April 2026
- Published by Elsevier in Electric Power Systems Research
- Vol. 259
Traveling wave based wide area backup protection for HVAC network interfacing MMC based HVDC system
- 30 April 2026
- Published by Elsevier in Electric Power Systems Research
- Vol. 259
Traveling wave based wide area backup protection for HVAC network interfacing MMC based HVDC system
- 1 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-16
Traveling Wave-Based Primary Protection and Fault Localization Scheme for MTDC Grid Considering IEC 61869-9 Measurement Standard
Traveling wave (TW) based protection and fault localization requires high sampling frequency measurements (500 kHz - 1 MHz) and are non-compliant to the IEC 61869-9 measurement standards, which allows maximum sampling frequency of 96 kHz for DC application. This work proposes a novel low sampling frequency (50 kHz) TW based primary protection and real-time DC fault localization technique for multi terminal high voltage DC (MTDC) grid which is compliant with the aforementioned measurement standard. In the proposed MTDC protection scheme, a TW arrival time (TWAT) is estimated under low sampling frequency measurement using cascaded combination of modified mathematical morphology gradient (MMG), sobel operator and linear regression tool. Subsequently, the TWAT information at both DC link terminals is communicated via dedicated communication channel compliant to IEC-61850-9-2 standard. And if the TWAT difference between DC terminals is less than the TW propagation threshold for the protected DC line, then a DC trip signal is issued to the associated hybrid DC circuit breaker (HDCCB). For fast power system restoration, the same TWAT information is also used for real-time fault localization in the faulted DC line, which is also compliant with IEC 61869-9 measurement standards. Finally, the practical feasibility of the proposed algorithm is demonstrated through control hardware-in-loop testing with real-time digital simulation setup and TI TMS320F28379d digital signal processor card.
- 1 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-16
Traveling Wave-Based Primary Protection and Fault Localization Scheme for MTDC Grid Considering IEC 61869-9 Measurement Standard
Traveling wave (TW) based protection and fault localization requires high sampling frequency measurements (500 kHz - 1 MHz) and are non-compliant to the IEC 61869-9 measurement standards, which allows maximum sampling frequency of 96 kHz for DC application. This work proposes a novel low sampling frequency (50 kHz) TW based primary protection and real-time DC fault localization technique for multi terminal high voltage DC (MTDC) grid which is compliant with the aforementioned measurement standard. In the proposed MTDC protection scheme, a TW arrival time (TWAT) is estimated under low sampling frequency measurement using cascaded combination of modified mathematical morphology gradient (MMG), sobel operator and linear regression tool. Subsequently, the TWAT information at both DC link terminals is communicated via dedicated communication channel compliant to IEC-61850-9-2 standard. And if the TWAT difference between DC terminals is less than the TW propagation threshold for the protected DC line, then a DC trip signal is issued to the associated hybrid DC circuit breaker (HDCCB). For fast power system restoration, the same TWAT information is also used for real-time fault localization in the faulted DC line, which is also compliant with IEC 61869-9 measurement standards. Finally, the practical feasibility of the proposed algorithm is demonstrated through control hardware-in-loop testing with real-time digital simulation setup and TI TMS320F28379d digital signal processor card.
- 16 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
An Efficient Travelling Wave based Fault Localization for MTDC Transmission System
This article proposes a low sampling frequency travelling wave-based fault location technique for the MTDC grid. It is based on the matrix pencil method applied on the DC terminal voltage samples in the sliding window moving along the time axis. The sliding matrix pencil method decomposes the voltage signal samples in the sliding window into time-indexed damping factors. In the absence of a travelling wave, the damping factor is zero. But in the presence of a travelling wave, depending on the position of the travelling wave in the sliding window, the damping factor is either positive, negative, or zero. After that linear regression is used to find the zero-crossing point of the time-indexed damping factor, which will help further to calculate the travelling wave arrival time. Finally, first travelling arrival time information from both DC terminal end will help to calculate the estimated DC fault location at the low sampling frequency.
- 16 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
An Efficient Travelling Wave based Fault Localization for MTDC Transmission System
This article proposes a low sampling frequency travelling wave-based fault location technique for the MTDC grid. It is based on the matrix pencil method applied on the DC terminal voltage samples in the sliding window moving along the time axis. The sliding matrix pencil method decomposes the voltage signal samples in the sliding window into time-indexed damping factors. In the absence of a travelling wave, the damping factor is zero. But in the presence of a travelling wave, depending on the position of the travelling wave in the sliding window, the damping factor is either positive, negative, or zero. After that linear regression is used to find the zero-crossing point of the time-indexed damping factor, which will help further to calculate the travelling wave arrival time. Finally, first travelling arrival time information from both DC terminal end will help to calculate the estimated DC fault location at the low sampling frequency.
- 22 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1013-1018
Fractional Order Control with Super Twisting Observer for AC Microgrid
In this paper, a fractional-order continuous control with a modified super twisting disturbance observer (STDO) for a microgrid (MG) is proposed. Transient accuracy under finite-time control is a challenging issue in Islanded MG with strong disturbance rejection. sliding mode control (SMC) with conventional Sliding surface design exhibits asymptotic response with chattering contamination in the control signal. If the terminal surface is used for finite-time control, singularity and chattering problem may occur. In order to achieve chattering free finite time response with no singularity problem, fractional second-order continuous control (FSCC) is proposed with STDO. In this paper, FSCC is primarily designed to improve transient response with finite-time control. Next, STDO is utilized to achieve strong robustness against disturbance with comprehensive chattering elimination by adding a fractional term. To capitalize on optimal control effort, event-triggering control is implemented. Stability proof and event trigger conditions are derived using rigorous Lyapunov based analysis. The efficacy of the proposed controller is tested under MATLAB/Simulink.
- 22 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1013-1018
Fractional Order Control with Super Twisting Observer for AC Microgrid
In this paper, a fractional-order continuous control with a modified super twisting disturbance observer (STDO) for a microgrid (MG) is proposed. Transient accuracy under finite-time control is a challenging issue in Islanded MG with strong disturbance rejection. sliding mode control (SMC) with conventional Sliding surface design exhibits asymptotic response with chattering contamination in the control signal. If the terminal surface is used for finite-time control, singularity and chattering problem may occur. In order to achieve chattering free finite time response with no singularity problem, fractional second-order continuous control (FSCC) is proposed with STDO. In this paper, FSCC is primarily designed to improve transient response with finite-time control. Next, STDO is utilized to achieve strong robustness against disturbance with comprehensive chattering elimination by adding a fractional term. To capitalize on optimal control effort, event-triggering control is implemented. Stability proof and event trigger conditions are derived using rigorous Lyapunov based analysis. The efficacy of the proposed controller is tested under MATLAB/Simulink.