YFYuan Fang

Yuan Fang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Yuan Fang has a total of 15 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Application of Randomized Matrix Approximation in 3-D Volume Integral Equation Domain Decomposition Method for Electromagnetic Scattering in Layered Media With Complex Objects

    by Dezhi Wang, Yunyun Hu, Yuan Fang, Qing Huo Liu

    Electromagnetic (EM) scattering of complex 3-D distributions in a layered-medium background is crucial in many remote sensing and geophysical applications, including ground-penetrating radar, microwave tomography, and atmospheric EM analysis. The Volume Integral Equation (VIE) method offers distinct advantages in simulating such problems. In particular, the recently proposed VIE combined with the Domain Decomposition Method (DDM) and accelerated by the Fast Fourier Transform (VIE-DDM-FFT) has shown promise. However, limitations in handling dense meshes along the z-axis led to the development of a low-rank approximation (LRA) algorithm, specifically the Adaptive Cross Approximation (ACA), for mutual matrix-vector multiplications (VIE-DDM-ACA). Despite reducing computational complexity, ACA suffers from premature, unstable, and unpredictable convergence, particularly when dealing with closely spaced objects, resulting in inaccuracies and inefficiencies. In this paper, we propose utilizing the Randomized Matrix Approximation (RMA) method for LRA. RMA provides superior low-rank factorization by requiring fewer ranks and exhibiting more stable and predictable convergence, making it particularly suitable for reconstructing mutual matrices in remote sensing scenarios involving closely spaced scatterers, such as subsurface imaging and layered-medium inversion problems. While RMA involves multiple matrix-vector multiplications (MVMs) during the preparation stage, these MVMs are independent and can be parallelized, mitigating computational costs. Additionally, the iterative MVMs in the equation-solving procedure retain linear complexity with a smaller coefficient compared to ACA due to the reduced rank requirements. Our results demonstrate that the RMA method outperforms ACA in terms of low-rank factorization and accuracy, making VIE-DDM-RMA more efficient than VIE-DDM-FFT and more accurate than VIE-DDM-ACA for EM scattering in remote sensing and geoscience applications involving close objects and complex scattering environments in layered media.

  • A Dual-Band Microwave Imaging System Prototype for Quantitative 3-D Dielectric Reconstruction

    by Yuan Fang, Kazem Bakian-Dogaheh, Mahta Moghaddam

    We present a microwave imaging (MWI) system prototype to reconstruct three-dimensional (3D) complex dielectric relaxation images of various complicated phantom models. The imaging cavity of this system is filled with a newly compounded emulsion. To achieve multi-frequency operation, the proposed system utilizes a new multi-frequency tapered patch antenna array. A novel method based on the principle component analysis (PCA) is first proposed to select optimal frequencies and useful data channels in MWI applications which is the major innovation of this paper. For 3D imaging, particularly under the black-box condition with no a priori information of the unknown targets, the enhanced variational Born iterative method (VBIM) is applied as the inverse solver, enabling the dielectric relaxation reconstruction from the multi-frequency measured data. Multiple experiments with various phantoms are conducted to evaluate the system’s performance and imaging capabilities. These include single, double, and multiple spherical targets filled with various water-isopropyl alcohol mixtures and submerged either directly in the background emulsion or within another water-alcohol mixture that is submerged in the emulsion. Imaging results, including the comparison between measured data and simulated data, multi-frequency and single-frequency reconstructed dielectric images, inversions with different PCA contribution thresholds, and reconstruction under black-box and preconditioned setup, can quantitatively demonstrate a good performance of the MWI system prototype.


  • A Multifrequency Inverse Algorithm for 3-D Microwave Imaging

    by Yuan Fang, Kazem Bakian-Dogaheh, Mahta Moghaddam

    A new multi-frequency inverse algorithm is presented based on the improved variational Born iterative method (VBIM) for three-dimensional (3D) quantitative microwave imaging. The proposed method is capable of reconstructing the 3D dielectric relaxation model using measured data acquired at multiple transmit frequencies. A least-squares optimization using the conjugate gradient method with Tikhonov regularization is applied at each VBIM step to relax the memory requirements. For evaluating the algorithm performance, two experiments are conducted with our newly designed microwave imaging system, and image reconstruction is performed under black-box conditions with no a-priori information. The phantom models in these experiments are: (1) a single ping-pong ball filled with 75% isopropyl-25% water mixture submerged into a plastic cup filled with 90% isopropyl-10% water mixture; (2) a co-planar distributed object consisting of five ping-pong balls filled with water at the same vertical level. Reconstructed 3D dielectric images demonstrate the accuracy of our proposed VBIM-based multi-frequency inverse algorithm using measured data with no a priori information.


  • A Quad-Band Near-Field Antenna Array for a Multistatic Microwave Imaging Chamber

    by Kazem Bakian-Dogaheh, Yuan Fang, Mahta Moghaddam

    A new quad-band tapered patch transmit-receive antenna array designed for a multistatic microwave imaging cavity system is presented. The reverberating cube-shaped chamber is filled with a matching fluid emulsion and encompasses 64 antenna elements mounted on its sidewalls (16 per panel). Four resonant frequencies that lie in the range of $0.5 - 3$ GHz are achieved. The design procedure is provided based on system constraints and performance requirements that need to be taken into account: (1) the near-field nature of the electromagnetic wave in the presence of a shielded chamber and (2) the propagation of waves into the immersion fluid within the imaging domain. The antenna array design was numerically verified, and its prototype was fabricated. Results show good agreement between measurements and simulations, achieving antenna system performance requirements.


  • Real-Time 3D Microwave Medical Imaging With Enhanced Variational Born Iterative Method

    by Yuan Fang, Kazem Bakian-Dogaheh, Mahta Moghaddam

    In this paper, we present a new variational Born iterative method (VBIM) for real-time microwave imaging (MWI) applications. The S-parameter volume integral equation and waveport vector Green’s function are implemented to utilize the measured signal of the MWI system. Meanwhile, the real and imaginary separation (RIS) approach is used at each iterative step to simultaneously reconstruct the dielectric permittivity and conductivity of unknown objects. Compared with the Born iterative method and distorted Born iterative method, VBIM requires less computational time to reach the convergence threshold. The graphics processing unit based acceleration technique is implemented for real-time imaging. To demonstrate the efficiency and accuracy of this VBIM-RIS method, synthetic analysis of a complex multi-layer spherical phantom is first conducted. Then, the algorithm is tested with measured data using our new MWI system prototype. Finally, a synthetic brain-tumor phantom model under a thermal therapy procedure is monitored to exemplify the real-time imaging with about 5 seconds per reconstruction frame.


  • A Versatile and Shelf-Stable Dielectric Coupling Medium for Microwave Imaging

    by Yuan Fang, Kazem Bakian-Dogaheh, John Stang, Alireza Tabatabaeenejad, Mahta Moghaddam

    Objective: To develop a new class of emulsions using a protein-based emulsifier as the coupling fluid for microwave imaging systems. Methods: In this paper, we provide a theoretical basis for engineering shelf-stable dielectric fluids, a step-by-step formulation method, and measurements of complex dielectric properties in the frequency range of 0.5-3 GHz, which can be applicable for many of the recent microwave imaging systems. Results: This medium was primarily designed for long-term stability while providing a controllable range of complex dielectric permittivities given different fractions of its constituents. Consequently, this emulsion shows dielectric stability in open air throughout a 7-day experiment and temperature insensitivity over the range of 0 ${\,^\circ }$ C to 60 ${^\circ }$ . Conclusions: This control over dielectric permittivity enables formulations that tune the background-to-target contrast to the linearizable regime of iterative inverse scattering algorithms. Accordingly, the emulsion conductivity can also be controlled and reduced to maintain the required signal-to-noise ratio within the dynamic range of the imaging system. The new formulation overcomes the practical challenges of engineering coupling fluids for microwave imaging systems, e.g., temporal stability, non-toxic, low sensitivity to temperature variation, and easy formulation from readily available and inexpensive materials. Significance: The achieved properties associated with this new fluid are of particular benefit to microwave imaging systems used in thermal therapy monitoring.


  • Discontinuous Galerkin modeling of 3D arbitrary anisotropic Q

    by Qiwei Zhan, Mingwei Zhuang, Yuan Fang, Qing Huo Liu

    For wave propagation problems, conventional time-domain anelastic attenuation modeling involves either Caputo fractional time derivatives for an exactly constant-Q model, thus leading to globally temporal memory effects; or auxiliary partial differential equations (PDEs) for a nearly constant-Q model, thus resulting in globally spatial operators. Therefore, memory and time consumptions increase tremendously, compared with the purely elastic counterpart. Moreover, the numerical models are usually limited to isotropic or transversely isotropic attenuation, due to the ambiguity of anisotropic attenuation parameterization. Therefore, it is indispensable to investigate an efficient method, to easily incorporate the general anisotropic attenuation effects in the time domain. To tackle these problems, we have first developed a Q-transformation rule, via the correspondence principle, revealing the validity range for a large enough Q value. Then, we construct a new constitutive equation, by extending the generalized Maxwell body, from the isotropic viscoelastic media to fully anisotropic scenario, i.e., as complex as triclinic attenuation. As a result, global memory effects are effectively localized, with several anelastic functions subject to ordinary differential equations, while preserving the original governing equations. An efficient hp-adaptive discontinuous Galerkin (DG) time-domain algorithm is implemented, where the Riemann problem is exactly solved. Consequently, the extra computation cost to incorporate Q effects is nearly negligible. Furthermore, we derive an analytical solution for the general anisotropic attenuation to verify this DG implementation.


  • Effect of high-energy X-ray irradiation on creep mechanisms in bone and dentin

    by Alix C. Deymier-Black, Anjali Singhal, Fang Yuan, Jonathan D. Almer, L. Catherine Brinson, David C. Dunand