WWWenli Wang

Wenli Wang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Wenli Wang has a total of 21 co-authors. Here are the top co-authors by number of shared publications:

  • Fuzhi Cao

    Key Laboratory of Ultra-Weak Magnetic Field Measurement Technology, Ministry of Education, School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing 100191, China

    10 shared publications
  • Nan An

    Key Laboratory of Ultra-Weak Magnetic Field Measurement Technology, Ministry of Education, School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing, China

    10 shared publications
  • Wen Li

    School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing, China

    9 shared publications
  • Chunhui Wang

    Key Laboratory of Ultra-Weak Magnetic Field Measurement Technology, Ministry of Education, School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing, China

    8 shared publications
  • Xiaolin Ning

    Beihang University

    7 shared publications
  • Weinan Xu

    School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing 100191, China

    6 shared publications

Latest Publications

  • Spatial Resolution of Low-Density OPM-MEG: A Comparative Analysis With High-Density EEG

    by Zhenfeng Gao, Fuzhi Cao, Nan An, Wen Li, Wenli Wang, Jianzhi Yang, Dawei Wang, Xiaolin Ning

    Electroencephalography (EEG) and magnetoencephalography (MEG) are noninvasive neuroimaging techniques used to detect and localize brain activity. Unlike cumbersome MEG systems that employ superconducting quantum interference devices, EEG and the emerging optically pumped magnetometer-based MEG (OPM-MEG) systems are wearable and compact, allowing subjects to move naturally during data acquisition. With limited sensor numbers, OPM sensors can be locally arranged for the brain area of interest to enhance the spatial resolution. In this study, we aimed to investigate the spatial resolution of low-density OPM-MEG with locally arranged sensor arrays by comparing it with high-density EEG, providing insights into its practical application. Simulations of three 32-channel local arrays targeting functional brain regions were compared to those obtained via a 128-channel EEG by using the resolution matrix as an indicator. To align with real-world scenarios, we further investigated the mechanism by which skull conductivity and coregistration errors affect source localization accuracy. We conducted median nerve stimulation experiments using both the constructed OPM-MEG and EEG to validate their source localization performance. The simulation results demonstrated that OPM-MEG provides spatial specificity comparable to or even exceeding EEG. In real-world experiments, both modalities achieved accurate localizations, with similar source distributions. Simulations and experiments confirmed the comparable spatial localization performance of both systems, highlighting the potential of low-density OPM-MEG for research on a specific brain function. Low-density OPM-MEG presents a promising alternative to high-density EEG, potentially improving accuracy and participant comfort.


  • Motion Artifact Suppression Method Based on Dynamic Background Field Adaptive Filtering for Wearable OPM-MEG

    by Chunhui Wang, Fuzhi Cao, Wen Li, Wenli Wang, Yong Li, Weinan Xu, Jianzhi Yang, Nan An

    Magnetoencephalography (MEG) is a noninvasive brain imaging technique that investigates dynamic brain changes by measuring magnetic fields generated by neural activities. Recently, significant advancements have been made in Optically Pumped Magnetometer-based Magnetoencephalography (OPM-MEG). Compared with conventional superconducting quantum interference device-based MEG, OPM-MEGs operate at room temperature, reducing costs and allowing more flexible sensor configurations. Most importantly, OPM-MEG allows for meas-urements during natural head movements, facilitating more nat-uralistic experiments and broader applications, including studies involving motor tasks and populations, such as young children or patients with movement disorders. However, motion-compatible OPM-MEGs face significant challenges because of the severe impact of motion artifacts on data quality. This study introduced a Dynamic Background Field Adaptive Filtering method (DBFAF) to suppress motion artifacts in OPM-MEG. The OPM-MEG data were processed by adaptively filtering out the motion artifacts measured using multiple orthogonally oriented OPM reference sensors fixed to a helmet. The simulation results demonstrate that the DBFAF method significantly improves data quality by effectively mitigating the impact of motion artifacts, surpassing the widely used moving-window regression methods. The efficacy and reliability of this method were further verified using median nerve stimulation in OPM-MEG experiments. This approach offers a novel solution for applying OPM-MEG in contexts involving participants’ head movements.


  • Source Imaging Method Based on Spatial Smoothing and Edge Sparsity (SISSES) and Its Application to OPM-MEG

    by Wen Li, Nan An, Fuzhi Cao, Wenli Wang, Chunhui Wang, Weinan Xu, Yang Gao, Xiaolin Ning

    Source estimation in magnetoencephalography (MEG) involves solving a highly ill-posed problem without a unique solution. Accurate estimation of the time course and spatial extent of the source is important for studying the mechanisms of brain activity and preoperative functional localization. Traditional methods tend to yield small-amplitude diffuse or large-amplitude focused source estimates. Recently, the structured sparsity-based source imaging algorithm has emerged as one of the most promising algorithms for improving source extent estimation. However, it suffers from a notable amplitude bias. To improve the spatiotemporal resolution of reconstructed sources, we propose a novel method called the source imaging method based on spatial smoothing and edge sparsity (SISSES). In this method, the temporal dynamics of sources are modeled using a set of temporal basis functions, and the spatial characteristics of the source are represented by a first-order Markov random field (MRF) model. In particular, sparse constraints are imposed on the MRF model residuals in the original and variation domains. Numerical simulations were conducted to validate the SISSES. The results demonstrate that SISSES outperforms benchmark methods for estimating the time course, location, and extent of patch sources. Additionally, auditory and median nerve stimulation experiments were performed using a 31-channel optically pumped magnetometer MEG system, and the SISSES was applied to the source imaging of these data. The results demonstrate that SISSES correctly identified the source regions in which brain responses occurred at different times, demonstrating its feasibility for various practical applications.


  • Source Extent Estimation in OPM-MEG: A Two-Stage Champagne Approach

    by Wen Li, Fuzhi Cao, Nan An, Wenli Wang, Chunhui Wang, Weinan Xu, Yang Gao, Xiaolin Ning

    The accurate estimation of source extent using magnetoencephalography (MEG) is important for the study of preoperative functional localization in epilepsy. Conventional source imaging techniques tend to produce diffuse or focused source estimates that fail to capture the source extent accurately. To address this issue, we propose a novel method called the two-stage Champagne approach (TS-Champagne). TS-Champagne divides source extent estimation into two stages. In the first stage, the Champagne algorithm with noise learning (Champagne-NL) is employed to obtain an initial source estimate. In the second stage, spatial basis functions are constructed from the initial source estimate. These spatial basis functions consist of potential activation source centers and their neighbors, and serve as spatial priors, which are incorporated into Champagne-NL to obtain a final source estimate. We evaluated the performance of TS-Champagne through numerical simulations. TS-Champagne achieved more robust performance under various conditions (i.e., varying source extent, number of sources, signal-to-noise level, and correlation coefficients between sources) than Champagne-NL and several benchmark methods. Furthermore, auditory and median nerve stimulation experiments were conducted using a 31-channel optically pumped magnetometer (OPM)-MEG system. The validation results indicated that the reconstructed source activity was spatially and temporally consistent with the neurophysiological results of previous OPM-MEG studies, further demonstrating the feasibility of TS-Champagne for practical applications.


  • Open Access

    Source imaging method based on diagonal covariance bases and its applications to OPM-MEG

    by Wen Li, Fuzhi Cao, Nan An, Wenli Wang, Chunhui Wang, Weinan Xu, Dexin Yu, Min Xiang, Xiaolin Ning


  • Source localization comparison and combination of OPM-MEG and fMRI to detect sensorimotor cortex responses

    by Nan An, Zhenfeng Gao, Wen Li, Fuzhi Cao, Wenli Wang, Weinan Xu, Chunhui Wang, Min Xiang, Yang Gao, Dawei Wang, et al.


  • Design of locally arranged sensor arrays in wearable OPM-MEG based on sensor volume constraints

    by Wenli Wang, Fuzhi Cao, Nan An, Wen Li, Weinan Xu, Chunhui Wang, Zhenfeng Gao, Dexin Yu, Yang Gao, Xiaolin Ning


  • Optical Co-Registration Method of Triaxial OPM-MEG and MRI

    by Fuzhi Cao, Nan An, Weinan Xu, Wenli Wang, Wen Li, Chunhui Wang, Min Xiang, Yang Gao, Xiaolin Ning

    The advent of optically pumped magnetometers (OPMs) facilitates the development of on-scalp magnetoencephalography (MEG). In particular, the triaxial OPM emerged recently, making simultaneous measurements of all three orthogonal components of vector fields possible. The detection of triaxial magnetic fields improves the interference suppression capability and achieves higher source localization accuracy using fewer sensors. The source localization accuracy of MEG is based on the accurate co-registration of MEG and MRI. In this study, we proposed a triaxial co-registration method according to combined principal component analysis and iterative closest point algorithms for use of a flexible cap. A reference phantom with known sensor positions and orientations was designed and constructed to evaluate the accuracy of the proposed method. Experiments showed that the average co-registered position errors of all sensors were approximately 1 mm and average orientation errors were less than 2.5° in the X - and Y orientations and less than 1.6° in the Z orientation. Furthermore, we assessed the influence of co-registration errors on the source localization using simulations. The average source localization error of approximately 1 mm reflects the effectiveness of the co-registration method. The proposed co-registration method facilitates future applications of triaxial sensors on flexible caps.


  • Effects of Different Head Models in Wearable OPM-MEG

    by Fuzhi Cao, Nan An, Wenli Wang, Weinan Xu, Wen Li, Chunhui Wang, Min Xiang, Yang Gao, Xiaolin Ning

    Optically pumped magnetometer (OPM)-based magnetoencephalography (MEG) has attracted significant attention due to its flexible sensor configuration and closer proximity to the scalp. The source localization technique of MEG is used in neuroscience and clinical research. Different head models have been developed to provide a forward solution for MEG source localization. However, the effects of different head models have not yet been studied under the new OPM-MEG measurement scenario. In this simulation study, we investigated the effects of eight head models [a local sphere (LS), a corrected sphere (CS), a boundary element method (BEM)-based, and five finite-element method (FEM)-based models, including isotropic three-, four-, and five-compartment and two anisotropic five-compartment head models] for forward and inverse solutions. In addition, we studied the effects of these eight head models in a more realistic environment, such as under sensor coregistration error and measurement noise. The results showed that the source localization error (LE) between the simplified head model and the isotropic five-compartment FEM model can reach 4–5 mm, emphasizing the necessity of using an elaborate head model. In addition, in the comparison of forward and inverse problems, the distinction of cerebrospinal fluid (CSF) showed the most obvious improvement. Thus, an FEM head model with a CSF compartment is recommended. Furthermore, a high level of measurement noise (>80%, the ratio of root mean square of the noise matrix to the data matrix) and high coregistration errors (rotation error > 2°) significantly reduced the contributions of realistic head models.


  • Multiple Source Detection Based on Spatial Clustering and Its Applications on Wearable OPM-MEG

    by Nan An, Fuzhi Cao, Wen Li, Wenli Wang, Weinan Xu, Chunhui Wang, Yang Gao, Min Xiang, Xiaolin Ning

    Objective: Magnetoencephalography (MEG) is a non-invasive technique that measures the magnetic fields of brain activity. In particular, a new type of optically pumped magnetometer (OPM)-based wearable MEG system has been developed in recent years. Source localization in MEG can provide signals and locations of brain activity. However, conventional source localization methods face the difficulty of accurately estimating multiple sources. The present study presented a new parametric method to estimate the number of sources and localize multiple sources. In addition, we applied the proposed method to a constructed wearable OPM-MEG system. Methods: We used spatial clustering of the dipole spatial distribution to detect sources. The spatial distribution of dipoles was obtained by segmenting the MEG data temporally into slices and then estimating the parameters of the dipoles on each data slice using the particle swarm optimization algorithm. Spatial clustering was performed using the spatial-temporal density-based spatial clustering of applications with a noise algorithm. The performance of our approach for detecting multiple sources was compared with that of four typical benchmark algorithms using the OPM-MEG sensor configuration. Results: The simulation results showed that the proposed method had the best performance for detecting multiple sources. Moreover, the effectiveness of the method was verified by a multimodel sensory stimuli experiment on a real constructed 31-channel OPM-MEG. Conclusion: Our study provides an effective method for the detection of multiple sources. Significance: With the improvement of the source localization methods, MEG may have a wider range of applications in neuroscience and clinical research.