Sofie Rohde
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Sofie Rohde has a total of 53 co-authors. Here are the top co-authors by number of shared publications:
Theo M M H de By
EACTS House EUROMACS Windsor, United Kingdom
5 shared publications- Eugen Sandica
Clinic for Pediatric Cardiac Surgery and Congenital Heart Defects, Heart and Diabetes Centre North Rhine-Westphalia, Ruhr-University of Bochum , Bad Oeynhausen, Germany
4 shared publications Kevin Veen
Department of Cardio-Thoracic Surgery, Erasmus University Medical Center , Rotterdam, Netherlands
4 shared publications- Antonio Amodeo
Heart Failure, Transplant and Mechanical Assist Device Unit, Bambino Gesù Children's Hospital, IRCCS , Piazza Sant'Onofrio, 4, 00165 Rome
3 shared publications Carlo Pace Napoleone
Regina Margherita Children’s Hospital Pediatric Cardiac Surgery Department Torino, Italy
3 shared publicationsJoanna Sliwka
Medical University of Silesia, Silesian Center for Heart Diseases Department of Cardiac Surgery, Transplantology and Vascular Surgery Zabrze, Poland
3 shared publications
Latest Publications
- 19 July 2024
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 66 (2)
The european registry for patients with mechanical circulatory support (EUROMACS): fourth paediatric EUROMACS (Paedi-EUROMACS) report
OBJECTIVES: The use of ventricular assist devices in children is increasing. However, absolute numbers in individual centers and countries remain small. Collaborative efforts such as the Paedi-EUROMACS are therefore essential in order to combine international experience with paediatric ventricular assist devices. In this paper, the results from the fourth Paedi-EUROMACS report are presented. METHODS: All paediatric (<19 years) patients supported by a ventricular assist device from the EUROMACS database were included. Patients are stratified into a congenital heart disease group and a group with a non-congenital aetiology. Endpoints included mortality, transplantation and recovery. Cox proportional hazard models were used to explore associated factors for mortality, cerebrovascular accident, and pump thrombosis. RESULTS: 590 primary implantations were included. The congenital group was significantly younger (2.5 versus 8.0 years respectively, p < 0.001) and were more commonly supported by a pulsatile flow device (73.5% vs 59.9%, p < 0.001). Mortality was significantly higher in the congenital group (30.8 vs 20.4%; p = 0.009) than in the non-congenital group. However, in multivariable analyses, congenital heart disease was not significantly associated with mortality (HR 1.285, CI 0.8111–2.036, p = 0.740). Pump thrombosis was the most frequently reported adverse event (377 events in 132 patients; 0.925 events per patient-year) and was significantly associated with BSA (HR 0.524 CI 0.333–0.823, p = 0.005), congenital heart disease (HR 1.641 CI 1.054–2.555, p = 0.028) and pulsatile flow support (HR 2.345 CI 1.406–3.910, p = 0.001) in multivariable analyses. CONCLUSIONS: This fourth Paedi-EUROMACS report highlights the increasing use of paediatric ventricular assist devices. The patient populations with congenital and non-congenital aetiology exhibit distinct characteristics and clinical outcomes.
- 19 July 2024
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 66 (2)
The european registry for patients with mechanical circulatory support (EUROMACS): fourth paediatric EUROMACS (Paedi-EUROMACS) report
OBJECTIVES: The use of ventricular assist devices in children is increasing. However, absolute numbers in individual centers and countries remain small. Collaborative efforts such as the Paedi-EUROMACS are therefore essential in order to combine international experience with paediatric ventricular assist devices. In this paper, the results from the fourth Paedi-EUROMACS report are presented. METHODS: All paediatric (<19 years) patients supported by a ventricular assist device from the EUROMACS database were included. Patients are stratified into a congenital heart disease group and a group with a non-congenital aetiology. Endpoints included mortality, transplantation and recovery. Cox proportional hazard models were used to explore associated factors for mortality, cerebrovascular accident, and pump thrombosis. RESULTS: 590 primary implantations were included. The congenital group was significantly younger (2.5 versus 8.0 years respectively, p < 0.001) and were more commonly supported by a pulsatile flow device (73.5% vs 59.9%, p < 0.001). Mortality was significantly higher in the congenital group (30.8 vs 20.4%; p = 0.009) than in the non-congenital group. However, in multivariable analyses, congenital heart disease was not significantly associated with mortality (HR 1.285, CI 0.8111–2.036, p = 0.740). Pump thrombosis was the most frequently reported adverse event (377 events in 132 patients; 0.925 events per patient-year) and was significantly associated with BSA (HR 0.524 CI 0.333–0.823, p = 0.005), congenital heart disease (HR 1.641 CI 1.054–2.555, p = 0.028) and pulsatile flow support (HR 2.345 CI 1.406–3.910, p = 0.001) in multivariable analyses. CONCLUSIONS: This fourth Paedi-EUROMACS report highlights the increasing use of paediatric ventricular assist devices. The patient populations with congenital and non-congenital aetiology exhibit distinct characteristics and clinical outcomes.
- 19 July 2024
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 66 (2)
Ventricular assist device support in paediatric patients with restrictive cardiomyopathy—clinical outcomes and haemodynamics
OBJECTIVES: Restrictive cardiomyopathy is rare and is generally associated with worse clinical outcomes compared to other cardiomyopathies. Ventricular assist device (VAD) support for these children is seldom applied and often hampered by the surgical difficulties. METHODS: All paediatric (<19 years) patients with a restricted cardiomyopathy supported by a VAD from the EUROMACS database were included and compared to patients with a dilated cardiomyopathy (retrospective database analyses). Participating centres were retrospectively contacted to provide additional detailed echo and Swan Ganz measurements to analyse the effect of VAD support on pulmonary artery pressure and right ventricular function. RESULTS: Forty-four paediatric VAD-supported patients diagnosed with restricted cardiomyopathy were included, with a median age at implantation of 5.0 years. Twenty-six of the 44 patient with a restricted cardiomyopathy survived to transplantation (59.1%), 16 died (36.4%) and 2 are still on ongoing VAD support (4.5%) after a median duration of support of 95.5 days (interquartile range 33.3–217.8). Transplantation probability after 1 and 2 years of VAD support in patients with a restricted cardiomyopathy were comparable to patients with a dilated cardiomyopathy (52.3% vs 51.4% and 59.5% vs 60.1%, P = 0.868). However, mortality probability was higher in the restricted cardiomyopathy cohort (35.8% vs 17.0% and 35.8% vs 19.0%, P = 0.005). Adverse event rates were high (cerebrovascular accident in 31.8%, pump thrombosis in 29.5%, major bleeding 25.0%, eventual biventricular support in 59.1%). In the atrially cannulated group, cerebrovascular accident and pump thrombosis occurred in twice as much patients (21.1% vs 40.0%, P = 0.595 and 15.8% vs 40.0%, P = 0.464; probably non-significant due to the small numbers). Pulmonary arterial pressures improved after implantation of a VAD, and 6 patients who were initially labelled as ineligible due to pulmonary hypertension could eventually be transplanted. CONCLUSIONS: VAD support in children with a restricted cardiomyopathy is rarely performed. Mortality and adverse event rates are high. On the other hand, survival to cardiac transplantation was 59.1% with all patients surviving the 1st 30 days after cardiac transplantation. Pulmonary arterial pressures improved while on support, potentially making cardiac transplantation a viable option for previously ineligible children.
- 19 July 2024
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 66 (2)
Ventricular assist device support in paediatric patients with restrictive cardiomyopathy—clinical outcomes and haemodynamics
OBJECTIVES: Restrictive cardiomyopathy is rare and is generally associated with worse clinical outcomes compared to other cardiomyopathies. Ventricular assist device (VAD) support for these children is seldom applied and often hampered by the surgical difficulties. METHODS: All paediatric (<19 years) patients with a restricted cardiomyopathy supported by a VAD from the EUROMACS database were included and compared to patients with a dilated cardiomyopathy (retrospective database analyses). Participating centres were retrospectively contacted to provide additional detailed echo and Swan Ganz measurements to analyse the effect of VAD support on pulmonary artery pressure and right ventricular function. RESULTS: Forty-four paediatric VAD-supported patients diagnosed with restricted cardiomyopathy were included, with a median age at implantation of 5.0 years. Twenty-six of the 44 patient with a restricted cardiomyopathy survived to transplantation (59.1%), 16 died (36.4%) and 2 are still on ongoing VAD support (4.5%) after a median duration of support of 95.5 days (interquartile range 33.3–217.8). Transplantation probability after 1 and 2 years of VAD support in patients with a restricted cardiomyopathy were comparable to patients with a dilated cardiomyopathy (52.3% vs 51.4% and 59.5% vs 60.1%, P = 0.868). However, mortality probability was higher in the restricted cardiomyopathy cohort (35.8% vs 17.0% and 35.8% vs 19.0%, P = 0.005). Adverse event rates were high (cerebrovascular accident in 31.8%, pump thrombosis in 29.5%, major bleeding 25.0%, eventual biventricular support in 59.1%). In the atrially cannulated group, cerebrovascular accident and pump thrombosis occurred in twice as much patients (21.1% vs 40.0%, P = 0.595 and 15.8% vs 40.0%, P = 0.464; probably non-significant due to the small numbers). Pulmonary arterial pressures improved after implantation of a VAD, and 6 patients who were initially labelled as ineligible due to pulmonary hypertension could eventually be transplanted. CONCLUSIONS: VAD support in children with a restricted cardiomyopathy is rarely performed. Mortality and adverse event rates are high. On the other hand, survival to cardiac transplantation was 59.1% with all patients surviving the 1st 30 days after cardiac transplantation. Pulmonary arterial pressures improved while on support, potentially making cardiac transplantation a viable option for previously ineligible children.
- 29 March 2024
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 65 (4)
Durable left ventricular assist device explantation following recovery in paediatric patients: Determinants and outcome after explantation
Myocardial recovery in children supported by a durable left ventricular assist device is a rare, but highly desirable outcome because it could potentially eliminate the need for a cardiac transplant and the lifelong need for immunosuppressant therapy and the risk of complications. However, experience with this specific outcome is extremely limited. All patients < 19 years old supported by a durable left ventricular assist device from the European Registry for Patients with Mechanical Circulatory Support database were included. Participating centres were approached for additional follow-up data after explantation. Associated factors for explantation due to myocardial recovery were explored using Cox proportional hazard models. The incidence of recovery in children supported by a durable left ventricular assist device was 11.7% (52/445; median duration of support, 122.0 days). Multivariable analyses showed body surface area (hazard ratio 0.229; confidence interval 0.093–0.565; P = 0.001) and a primary diagnosis of myocarditis (hazard ratio 4.597; confidence interval 2.545–8.303; P < 0.001) to be associated with recovery. Left ventricular end-diastolic diameter in children with myocarditis was not associated with recovery. Follow-up after recovery was obtained for 46 patients (88.5%). Sustained myocardial recovery was reported in 33/46 (71.7%) at the end of the follow-up period (28/33; >2 year). Transplants were performed in 6/46 (11.4%) (in 5 after a ventricular assist device was reimplanted). Death occurred in 7/46 (15.2%). Myocardial recovery occurs in a substantial portion of paediatric patients supported with durable left ventricular assist devices, and sustainable recovery is seen in around three-quarters of them. Even children with severely dilated ventricles due to myocarditis can show recovery. Clinicians should be attentive to (developing) myocardial recovery. These results can be used to develop internationally approved paediatric weaning guidelines.
- 29 March 2024
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 65 (4)
Durable left ventricular assist device explantation following recovery in paediatric patients: Determinants and outcome after explantation
Myocardial recovery in children supported by a durable left ventricular assist device is a rare, but highly desirable outcome because it could potentially eliminate the need for a cardiac transplant and the lifelong need for immunosuppressant therapy and the risk of complications. However, experience with this specific outcome is extremely limited. All patients < 19 years old supported by a durable left ventricular assist device from the European Registry for Patients with Mechanical Circulatory Support database were included. Participating centres were approached for additional follow-up data after explantation. Associated factors for explantation due to myocardial recovery were explored using Cox proportional hazard models. The incidence of recovery in children supported by a durable left ventricular assist device was 11.7% (52/445; median duration of support, 122.0 days). Multivariable analyses showed body surface area (hazard ratio 0.229; confidence interval 0.093–0.565; P = 0.001) and a primary diagnosis of myocarditis (hazard ratio 4.597; confidence interval 2.545–8.303; P < 0.001) to be associated with recovery. Left ventricular end-diastolic diameter in children with myocarditis was not associated with recovery. Follow-up after recovery was obtained for 46 patients (88.5%). Sustained myocardial recovery was reported in 33/46 (71.7%) at the end of the follow-up period (28/33; >2 year). Transplants were performed in 6/46 (11.4%) (in 5 after a ventricular assist device was reimplanted). Death occurred in 7/46 (15.2%). Myocardial recovery occurs in a substantial portion of paediatric patients supported with durable left ventricular assist devices, and sustainable recovery is seen in around three-quarters of them. Even children with severely dilated ventricles due to myocarditis can show recovery. Clinicians should be attentive to (developing) myocardial recovery. These results can be used to develop internationally approved paediatric weaning guidelines.
- Open Access
- 27 July 2023
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 64 (2)
Myocardial recovery in children supported with a durable ventricular assist device—a systematic review
OBJECTIVES: A small percentage of paediatric patients supported with a ventricular assist device (VAD) can have their device explanted following myocardial recovery. The goal of this systematic review is to summarize the current literature on the clinical course in these children after weaning. METHODS: A systematic literature search was performed on 27 May 2022 using Embase, Medline ALL, Web of Science Core Collection, Cochrane Central Register of Controlled Trials and Google Scholar to include all literature on paediatric patients supported by a durable VAD during the last decade. Overlapping study cohorts and registry-based studies were filtered out. RESULTS: Thirty-seven articles were included. Eighteen of them reported on the incidence of recovery in cohort studies, with an overall incidence rate of 8.7% (81/928). Twenty-two of the included articles reported on clinical outcomes after VAD explantation (83 patients). The aetiologies varied widely and were not limited to diseases with a natural transient course like myocarditis. Most of the patients in the included studies (70; 84.3%) were supported by a Berlin Heart EXCOR, and in 66.3% (55/83), only the left ventricle had to be supported. The longest follow-up period was 19.1 years, and multiple studies reported on long-term myocardial recovery. Fewer than half of the reported deaths had a cardiac cause. CONCLUSIONS: Myocardial recovery during VAD support is dependent on various contributing components. The interactions among patient-, device-, time- and hospital-related factors are complex and not yet fully understood. Long-term recovery after VAD support is achievable, even after a long duration of VAD support, and even in patients with aetiologies different from myocarditis or post-cardiotomy heart failure. More research is needed on this favourable outcome after VAD support.
- 27 July 2023
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 64 (2)
Open AccessMyocardial recovery in children supported with a durable ventricular assist device—a systematic review
OBJECTIVES: A small percentage of paediatric patients supported with a ventricular assist device (VAD) can have their device explanted following myocardial recovery. The goal of this systematic review is to summarize the current literature on the clinical course in these children after weaning. METHODS: A systematic literature search was performed on 27 May 2022 using Embase, Medline ALL, Web of Science Core Collection, Cochrane Central Register of Controlled Trials and Google Scholar to include all literature on paediatric patients supported by a durable VAD during the last decade. Overlapping study cohorts and registry-based studies were filtered out. RESULTS: Thirty-seven articles were included. Eighteen of them reported on the incidence of recovery in cohort studies, with an overall incidence rate of 8.7% (81/928). Twenty-two of the included articles reported on clinical outcomes after VAD explantation (83 patients). The aetiologies varied widely and were not limited to diseases with a natural transient course like myocarditis. Most of the patients in the included studies (70; 84.3%) were supported by a Berlin Heart EXCOR, and in 66.3% (55/83), only the left ventricle had to be supported. The longest follow-up period was 19.1 years, and multiple studies reported on long-term myocardial recovery. Fewer than half of the reported deaths had a cardiac cause. CONCLUSIONS: Myocardial recovery during VAD support is dependent on various contributing components. The interactions among patient-, device-, time- and hospital-related factors are complex and not yet fully understood. Long-term recovery after VAD support is achievable, even after a long duration of VAD support, and even in patients with aetiologies different from myocarditis or post-cardiotomy heart failure. More research is needed on this favourable outcome after VAD support.
- Open Access
- 8 November 2022
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 63 (1)
Outcomes in small children on Berlin Heart EXCOR support: age and body surface area as clinical predictive factors
The Berlin Heart EXCOR (BHE) offers circulatory support across all paediatric ages. Clinically, the necessary care and the outcomes differ in various age groups. The EUROMACS database was used to study age- and size-related outcomes for this specific device. All patients n = 74, P = 0.684, P = 0.679). Factors associated with a transplant (n = 175) were age (hazard ratio 1.07, P = 0.006) and aetiology other than congenital heart disease (hazard ratio 1.46, P = 0.020). Recovery rates (n = 42) were highest in patients with a BSA of 2 (21.8% vs 4.3–7.6% at 1 year, P = 0.00534). Patients with a BSA of ≥0.73 m2 had a lower risk of early pump thrombosis but a higher risk of early bleeding compared to children with a BSA of 2. Mortality rates in Berlin Heart-supported patients cannot be predicted by age or BSA. Recovery rates are remarkably high in the smallest patient category (BSA 2). This underscores that the BHE is a viable therapeutic option, even for the smallest and youngest patients.
- 8 November 2022
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 63 (1)
Open AccessOutcomes in small children on Berlin Heart EXCOR support: age and body surface area as clinical predictive factors
The Berlin Heart EXCOR (BHE) offers circulatory support across all paediatric ages. Clinically, the necessary care and the outcomes differ in various age groups. The EUROMACS database was used to study age- and size-related outcomes for this specific device. All patients n = 74, P = 0.684, P = 0.679). Factors associated with a transplant (n = 175) were age (hazard ratio 1.07, P = 0.006) and aetiology other than congenital heart disease (hazard ratio 1.46, P = 0.020). Recovery rates (n = 42) were highest in patients with a BSA of 2 (21.8% vs 4.3–7.6% at 1 year, P = 0.00534). Patients with a BSA of ≥0.73 m2 had a lower risk of early pump thrombosis but a higher risk of early bleeding compared to children with a BSA of 2. Mortality rates in Berlin Heart-supported patients cannot be predicted by age or BSA. Recovery rates are remarkably high in the smallest patient category (BSA 2). This underscores that the BHE is a viable therapeutic option, even for the smallest and youngest patients.
- Open Access
- 18 July 2022
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 62 (3)
Cerebrovascular accidents in paediatric patients supported by the Berlin Heart EXCOR
Ventricular assist device support as a bridge to transplant or recovery is a well-established therapy in children on the cardiac transplant waiting list. The goal of this study was to investigate the incidence of and the associated factors for cerebrovascular accidents in paediatric patients supported by a Berlin Heart EXCOR. All patients P = 0.040; hazard ratio 11.300, P = 0.037). At the 1-year follow-up, 44.4% of the patients had received a transplant, 13.1% were weaned after recovery and 24.5% had died. Event rates for mortality showed a significantly decreasing trend. Paediatric ventricular assist device support is associated with important adverse events, especially in the early phase after the device is implanted. Pump thrombosis and the need for a secondary right ventricular assist device are associated with cerebrovascular accidents. Furthermore, an encouragingly high rate of recovery in this patient population was shown, and death rates declined. More complete input of data into the registry, especially concerning anticoagulation protocols, would improve the data.
- 18 July 2022
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 62 (3)
Open AccessCerebrovascular accidents in paediatric patients supported by the Berlin Heart EXCOR
Ventricular assist device support as a bridge to transplant or recovery is a well-established therapy in children on the cardiac transplant waiting list. The goal of this study was to investigate the incidence of and the associated factors for cerebrovascular accidents in paediatric patients supported by a Berlin Heart EXCOR. All patients P = 0.040; hazard ratio 11.300, P = 0.037). At the 1-year follow-up, 44.4% of the patients had received a transplant, 13.1% were weaned after recovery and 24.5% had died. Event rates for mortality showed a significantly decreasing trend. Paediatric ventricular assist device support is associated with important adverse events, especially in the early phase after the device is implanted. Pump thrombosis and the need for a secondary right ventricular assist device are associated with cerebrovascular accidents. Furthermore, an encouragingly high rate of recovery in this patient population was shown, and death rates declined. More complete input of data into the registry, especially concerning anticoagulation protocols, would improve the data.