XWXinzui Wang

Xinzui Wang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Xinzui Wang has a total of 37 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A Decade of Progress in Lower-Limb Exoskeletons for Elderly Populations—Technological Innovations, Clinical Applications, and Challenges

    by Zongwei Zhang, Dongbao Sui, Tianshuo Wang, Tianjiao Zheng, Sikai Zhao, Tian Xu, Haotian Ju, Yu Zhang, Yun Yang, Xinzui Wang

    This narrative state-of-the-art review synthesizes a decade of progress (2015–2026) in lower-limb exoskeletons designed for elderly populations, covering technological innovations, clinical applications, and implementation challenges. Three structured syntheses organize the evidence: a chronological comparison of representative devices, a paradigm-level comparison of control strategies, and an appraisal of clinical studies ranked by descending level of experimental control. Technologically, reported device masses span two orders of magnitude (from 40 kg to 0.459 kg) across heterogeneous device categories and assistance levels, with hybrid and quasi-passive actuation driving mass reduction; multimodal sensing fusing inertial, force, and electromyographic signals supporting reliable intent recognition; and model-based and data-driven control converging toward hybrid architectures. Clinically, exoskeletons support mobility enhancement, gait rehabilitation, and fall prevention in older adults, yet hardware validation relies largely on healthy young or single-subject testing, much of the clinical evidence comes from neurological and critically ill populations, and large randomized controlled trials in elderly cohorts remain scarce. Implementation is further constrained by device mass, energy autonomy, safety assurance, cost, and user acceptance, including stigma and appearance concerns. We map five research directions onto these challenges and formulate open questions concerning personalized assistance, minimum viable hardware, energy autonomy, clinical evidence generation, and home-based acceptance, providing a reference for the design and clinical translation of elderly-oriented exoskeletons.

  • Open Access

    Structural Design and Analysis of Lower Limb Exoskeleton Rehabilitation Robots

    by Ruizhi Liang, Hui Fu, Xinzui Wang

    The lower limb exoskeleton rehabilitation robot is a type of robot that can assist patients with motor dysfunction caused by stroke in limb movement and rehabilitation training. In response to the limited applicability and low flexibility of current lower limb exoskeleton robots, this paper designs a highly adaptable lower limb exoskeleton robot through Solidworks, which has the characteristics of continuous leg length adjustment and structural simplification. The robot has a single lower limb with 3 degrees of freedom, using only the minimum but necessary degrees of freedom to achieve walking motion, thereby reducing the complexity of the mechanism. In addition, the design also avoids the negative impact of joint size on human health and foot movement, and introduces a waist width adjustment mechanism to adapt to users of different body types. Finally, using Ansys Workbench finite element analysis software, static and modal analyses were conducted on different stages of robot motion. The experimental results showed that this design scheme can achieve effective force distribution throughout the entire walking cycle, verifying the feasibility of the structural design.

  • Open Access

    Design and kinematics Analysis of Folding Mechanism of Patient Stretcher

    by Shaoxin Wen, Xinzui Wang, Fucheng Cao, Hui Fu

  • Design and Analysis of Turnover Function of Nursing Bed Based on Ergonomics

    by Weiliang Zeng, Xinzui Wang, Fucheng Cao, Haibing Xin, Xihua Li, Zhaobo Li, Hui Fu


  • Open Access

    Design and Simulation Analysis of the Patient Transfer Machine

    by Shaoxin Wen, Xinzui Wang, Fucheng Cao, Hui Fu

    In response to the low level of automation of the tools used for patient transfer in hospitals and the resulting shortage of nursing personnel, this paper studies the characteristics of existing transfer products and related structural features. A transfer machine based on static transfer is proposed, which can achieve patient transfer between a hospital bed and a stretcher truck. In this paper, the overall structure of the transfer machine has been designed in detail, and the structural design and analysis of important transmission components have been carried out. The finite element strength analysis of the main bearing components has been carried out. Finally, the selection of driving components based on their functions has been carried out. This study provides theoretical and technical support for the development of subsequent transfer machines.

  • Open Access

    EEG signal classification of tinnitus based on SVM and sample entropy

    by Mai Jianbiao, Wang Xinzui, Li Zhaobo, Liu Juan, Zhang Zhongwei, Fu Hui

    The prevalence of tinnitus is high and seriously affects the daily life of patients. As the pathogenesis of tinnitus is not yet clear, there is a lack of rapid and objective diagnostic modalities. In order to provide clinicians with an objective diagnostic approach, this paper combines time-frequency domain and non-linear power analysis to investigate the differences in the specificity of the EEG signal in tinnitus patients compared to healthy subjects. In this paper, resting-state electroencephalograms (EEG) were collected from 10 cases each of tinnitus patients and healthy subjects, and the data from the two groups were compared in the δ (0.5 − 3 .5 Hz), θ (4 − 7.5 Hz), α1 (8 − 10 Hz), α2 (10 − 12 Hz), β1 (13 − 18 Hz), β2 (18.5 − 21 Hz), β3 (21.5 − 30 Hz), and γ (30.5 − 44 Hz) bands for the differences in sample entropy values. The results of the resting state experiment revealed that the δ, α2 and β1 band samples of tinnitus patients all had greater entropy values than healthy subjects, with extremely significant differences compared to healthy subjects (p < 0.01). It is mainly concentrated in the δ band in the right parietal region of the cerebral cortex, the α2 band in the central region, and the γ band in the left prefrontal region. Finally, support vector machines combined with optimal feature combinations were used to achieve objective recognition of tinnitus disorders, with an 8.58% increase in accuracy compared to other features. Through the above study, entropy reflects the degree of chaos in the brain and the chaotic characteristics of the resting state EEG signal can characterise the onset of tinnitus, the results of which can help clinicians in the early diagnosis of tinnitus.


  • Open Access

    Objective Recognition of Tinnitus Location Using Electroencephalography Connectivity Features

    by Zhaobo Li, Xinzui Wang, Weidong Shen, Shiming Yang, David Y. Zhao, Jimin Hu, Dawei Wang, Juan Liu, Haibing Xin, Yalun Zhang, et al.

    Purpose: Tinnitus is a common but obscure auditory disease to be studied. This study will determine whether the connectivity features in electroencephalography (EEG) signals can be used as the biomarkers for an efficient and fast diagnosis method for chronic tinnitus.Methods: In this study, the resting-state EEG signals of tinnitus patients with different tinnitus locations were recorded. Four connectivity features [including the Phase-locking value (PLV), Phase lag index (PLI), Pearson correlation coefficient (PCC), and Transfer entropy (TE)] and two time-frequency domain features in the EEG signals were extracted, and four machine learning algorithms, included two support vector machine models (SVM), a multi-layer perception network (MLP) and a convolutional neural network (CNN), were used based on the selected features to classify different possible tinnitus sources.Results: Classification accuracy was highest when the SVM algorithm or the MLP algorithm was applied to the PCC feature sets, achieving final average classification accuracies of 99.42 or 99.1%, respectively. And based on the PLV feature, the classification result was also particularly good. And MLP ran the fastest, with an average computing time of only 4.2 s, which was more suitable than other methods when a real-time diagnosis was required.Conclusion: Connectivity features of the resting-state EEG signals could characterize the differentiation of tinnitus location. The connectivity features (PCC and PLV) were more suitable as the biomarkers for the objective diagnosing of tinnitus. And the results were helpful for clinicians in the initial diagnosis of tinnitus.


  • Open Access

    Electroencephalogram signal characterization of tinnitus patients based on sample entropy algorithm and wavelet transform

    by Jianbiao Mai, Xinzui Wang, Zhaobo Li, Haiyin Jia, Hui Fu

    Tinnitus is a disembodied, abnormal sound hallucination in the ear or skull, such as buzzing or hissing, in the absence of an external sound source. Tinnitus is a subjective sensation with no objective observable signs, and its causes are extremely complex. This paper explores the differences in sample entropy of EEG signals between tinnitus patients and normal subjects at different electrodes, using the non-parametric test Kruskal-Wallis test to find areas where there are significant differences between the different lateral tinnitus groups and the control group. Thirty tinnitus patients and 10 healthy controls were used to participate in the scalp EEG signal acquisition. The wavelet transform was first chosen to obtain the activity of each frequency band of the EEG, and then the electrophysiological differences between the two experimental groups were investigated by comparing the sample entropy of the EEG of the tinnitus patients with that of the healthy controls. The results reflect significant differences (p<0.05) in tinnitus patients at FT7, T7, C5, C6, TP7 and CP5 electrodes, mainly in the Delta band. These results compare the abnormalities of sample entropy in the resting state of patients with tinnitus on different sides of the ear with those of controls from an electroneuro-physiological perspective, and are expected to be used as a potential characteristic indicator to distinguish normal people from tinnitus patients for the auxiliary diagnosis of tinnitus and to provide physicians with an aid in diagnosing depressed patients.


  • Open Access

    Abnormal resting state EEG power spectral in patients with tinnitus on different sides of the ear

    by HaiYin Jia, ZhaoBo Li, XinZui Wang

    Tinnitus is a symptom of sound perception in the absence of external sound stimulation, and most patients have unilateral tinnitus, with more tinnitus on the left than on the right. In this paper, the resting EEG data of 10 patients with binaural tinnitus, 10 patients with left tinnitus and 10 healthy controls were collected, and two 10-s segments of resting EEG data were intercepted from each group for approximately 10 min. The absolute and relative power was calculated by fast Fourier transform. The results showed that more frequency bands were significantly different in the left tinnitus patients compared to the bilateral tinnitus patients and the right tinnitus patients, and where significant differences were demonstrated, the absolute and relative power was higher in the Delta and Theta bands of the tinnitus patients than in the control group. In conclusion, these results compare the resting state EEG power spectrum abnormalities in patients with tinnitus on different sides with healthy controls from an electroencephalographic perspective, and are expected to be used as an evaluation criterion in the future to provide a more refined and precise treatment plan for patients with tinnitus on different sides and to improve the efficiency of treatment.