Dante Inga Narváez
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Dante Inga Narváez has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Marcelo Gradella Villalva
Laboratório de Energia e Sistemas Fotovoltaicos
2 shared publications - Arturo Rojas-Moreno
Universidad de Ingeniería y Tecnología (UTEC)
1 shared publication - Callata Rosadio Ruben
Universidad de Ingenieria y Tecnologia - UTEC,Dept. of Electronics and Mechatronics,Lima,Peru
1 shared publication David Pompermaier
Center for Advanced Studies of Social and Environmental (CEAPS),Santarm,Brazil
1 shared publication- Elvis Jara Alegria
Department of Electrical and Mechatronics Engineering, University of Engineering and Technology—UTEC, Lima 15063, Peru
1 shared publication - Ernesto Ruppert Filho
School of Electrical and Computer Engineering, University of Campinas, Campinas, Brazil
1 shared publication
Latest Publications
- 6 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Real-Time Wireless Centralized Control of the Level-Temperature Process in a Multipurpose Tank
In this work, a centralized MIMO (Multiple-Input Multiple-Output) integer-order control and a centralized MIMO fractional-order control, both wireless, are implemented in order to simultaneously control the water level and temperature of the upper tank in a multipurpose plant located in the Automation Laboratory of the University of Engineering and Technology (UTEC), in Peru. For the implementation of the wireless control systems, Siemens SCALANCE W774 and W734 devices were used, which operated with the Profinet communication protocol. The results obtained in the experiments demonstrate that the fractional-order centralized control approach exhibits better performance in level control compared to the integer-order centralized control approach, especially in terms of overshoot percentage and settling time. Regarding temperature control, the fractional-order centralized control approach shows a lower overshoot percentage and a lower steady-state error. However, in terms of settling time, the integer-order centralized control was better compared to its fractional counterpart.
- 6 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Real-Time Wireless Centralized Control of the Level-Temperature Process in a Multipurpose Tank
In this work, a centralized MIMO (Multiple-Input Multiple-Output) integer-order control and a centralized MIMO fractional-order control, both wireless, are implemented in order to simultaneously control the water level and temperature of the upper tank in a multipurpose plant located in the Automation Laboratory of the University of Engineering and Technology (UTEC), in Peru. For the implementation of the wireless control systems, Siemens SCALANCE W774 and W734 devices were used, which operated with the Profinet communication protocol. The results obtained in the experiments demonstrate that the fractional-order centralized control approach exhibits better performance in level control compared to the integer-order centralized control approach, especially in terms of overshoot percentage and settling time. Regarding temperature control, the fractional-order centralized control approach shows a lower overshoot percentage and a lower steady-state error. However, in terms of settling time, the integer-order centralized control was better compared to its fractional counterpart.
- 20 July 2022
- Published by Springer Nature
- p. 652-662
Decentralized Fuzzy Control for Minimum and Non-minimum Phase of a Coupled Four-Tank System
- 20 July 2022
- Published by Springer Nature
- p. 652-662
Decentralized Fuzzy Control for Minimum and Non-minimum Phase of a Coupled Four-Tank System
- 1 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Optimum design of autonomous PV-diesel-battery hybrid systems: case study at Tapajós-Arapiuns extractive reserve in Brazil
Hybrid energy systems are an attractive alternative for power generation, specially in isolated areas. By connecting diesel generator and battery system to solar-photovoltaic or wind-turbine based generators, several benefits are obtained: higher reliability, energy quality and less oscillations in energy delivery. In this work, a photovoltaic-diesel-battery hybrid system in Tapajós-Arapiuns extractive reserve in Brazil is studied. That hybrid system is formed by a photovoltaic generator, battery system, diesel generator and isolated loads that are variable throughout the year. For that purpose, HOMER software was employed, so load-following and cycle-charging dispatch strategies were analysed with hourly-based data for a typical year. Results showed that load-following dispatch strategy is the best option, leading to energy productions of about 85.6% from the photovoltaic generator and 14.4% from the diesel generator.
- 1 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Optimum design of autonomous PV-diesel-battery hybrid systems: case study at Tapajós-Arapiuns extractive reserve in Brazil
Hybrid energy systems are an attractive alternative for power generation, specially in isolated areas. By connecting diesel generator and battery system to solar-photovoltaic or wind-turbine based generators, several benefits are obtained: higher reliability, energy quality and less oscillations in energy delivery. In this work, a photovoltaic-diesel-battery hybrid system in Tapajós-Arapiuns extractive reserve in Brazil is studied. That hybrid system is formed by a photovoltaic generator, battery system, diesel generator and isolated loads that are variable throughout the year. For that purpose, HOMER software was employed, so load-following and cycle-charging dispatch strategies were analysed with hourly-based data for a typical year. Results showed that load-following dispatch strategy is the best option, leading to energy productions of about 85.6% from the photovoltaic generator and 14.4% from the diesel generator.
- 1 November 2018
- Published by Elsevier in Electric Power Systems Research
- Vol. 164, 47-60
Performance comparison of DC and AC controllers for a two-stage power converter in energy storage application
- 1 November 2018
- Published by Elsevier in Electric Power Systems Research
- Vol. 164, 47-60
Performance comparison of DC and AC controllers for a two-stage power converter in energy storage application