Xiao Guo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Xiao Guo has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Guozhu Chen
College of Electrical Engineering, Zhejiang University, Hangzhou, China
3 shared publications - Hongyi Lin
College of Electrical Engineering, Zhejiang University, Hangzhou, China
2 shared publications - Dongdong Chen
School of Electronics and Electrical Engineering, Minnan University of Science and Technology, Quanzhou, China
1 shared publication - Ranchen Yang
School of Automation and Electrical Engineering, Zhejiang University of Science and Technology, Hangzhou, China
1 shared publication Shijie Wu
College of Electrical Engineering and Automation Fuzhou University, Fuzhou, China
1 shared publication- Zhenyu Li
School of Automation and Electrical Engineering, Zhejiang University of Science and Technology, Hangzhou, China
1 shared publication
Latest Publications
- Open Access
A Novel Voltage Sag Detection Method Based on a Selective Harmonic Extraction Algorithm for Nonideal Grid Conditions
Voltage sag detection is utilized to capture the sag occurrence moment and calculate the sag depth of power grid voltage in real time, so as to generate reference voltage for controlling voltage interactive equipment such as dynamic voltage restorers (DVRs). However, the traditional voltage sag detection methods based on synchronously rotating frames (SRFs) are unable to acquire high-precision sag information under nonideal grid conditions such as unbalance or harmonic interference. In order to enhance the immunity of the sag detection, a method based on a selective harmonic extraction algorithm (SHEA) is proposed in this paper. Firstly, the state-space model of SHEA is established using discrete orthogonal basis to decouple and separate the signal of target frequency and the signal of interference frequency. The controllability, stability and convergence of SHEA are analyzed theoretically and serve as the criteria for parameter tuning. Moreover, a gain compensator (GC) is used to improve the low and middle frequency gains of the voltage sag detection method based on SHEA so that the dynamic response speed for sag judgment can be optimized quantitatively. The simulation results indicate that the proposed voltage sag detection method has good dynamic and steady-state performance under nonideal power grid conditions such as unbalanced sag, frequency drift, phase variation and harmonic interference.
Open AccessA Novel Voltage Sag Detection Method Based on a Selective Harmonic Extraction Algorithm for Nonideal Grid Conditions
Voltage sag detection is utilized to capture the sag occurrence moment and calculate the sag depth of power grid voltage in real time, so as to generate reference voltage for controlling voltage interactive equipment such as dynamic voltage restorers (DVRs). However, the traditional voltage sag detection methods based on synchronously rotating frames (SRFs) are unable to acquire high-precision sag information under nonideal grid conditions such as unbalance or harmonic interference. In order to enhance the immunity of the sag detection, a method based on a selective harmonic extraction algorithm (SHEA) is proposed in this paper. Firstly, the state-space model of SHEA is established using discrete orthogonal basis to decouple and separate the signal of target frequency and the signal of interference frequency. The controllability, stability and convergence of SHEA are analyzed theoretically and serve as the criteria for parameter tuning. Moreover, a gain compensator (GC) is used to improve the low and middle frequency gains of the voltage sag detection method based on SHEA so that the dynamic response speed for sag judgment can be optimized quantitatively. The simulation results indicate that the proposed voltage sag detection method has good dynamic and steady-state performance under nonideal power grid conditions such as unbalanced sag, frequency drift, phase variation and harmonic interference.
- 23 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 58 (4) , 5469-5479
A Frequency Adaptive Repetitive Control for Active Power Filter With 380V/75A SiC-Inverter
Active power filters (APFs) with repetitive control (RC) could compensate for the harmonics. However, there are some problems in IGBT-380V-APFs with RC, such as the adaptability of grid frequency varying because of the noninteger value of RC parameters. SiC- mosfet s that could reach high switching frequency provide a new way to increase the compensation accuracy and the frequency adaptability for 380V/APFs. In this article, a novel frequency adaptive fast repetitive control (FAFRC) for APF with SiC- mosfet inverter to achieve optimal performance in variable frequency girds through changing RC order N was proposed. Taking the advantage of the high switching and sampling frequency of SiC-APF, the control method proposed could compensate for the harmonics more accurately with an integer RC order N . The control method with 50 kHz switching and the sampling frequency is described, designed, and verified experimentally in a two-level 380V/75A APF prototype made up of SiC- mosfet s, which volume is 37L that 66% of IGBT-APFs. The results obtained that 380V/75A-SiC-APFs with the control method proposed have a high compensation accuracy (THD<5%) with the grid frequency variations.
- 23 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 58 (4) , 5469-5479
A Frequency Adaptive Repetitive Control for Active Power Filter With 380V/75A SiC-Inverter
Active power filters (APFs) with repetitive control (RC) could compensate for the harmonics. However, there are some problems in IGBT-380V-APFs with RC, such as the adaptability of grid frequency varying because of the noninteger value of RC parameters. SiC- mosfet s that could reach high switching frequency provide a new way to increase the compensation accuracy and the frequency adaptability for 380V/APFs. In this article, a novel frequency adaptive fast repetitive control (FAFRC) for APF with SiC- mosfet inverter to achieve optimal performance in variable frequency girds through changing RC order N was proposed. Taking the advantage of the high switching and sampling frequency of SiC-APF, the control method proposed could compensate for the harmonics more accurately with an integer RC order N . The control method with 50 kHz switching and the sampling frequency is described, designed, and verified experimentally in a two-level 380V/75A APF prototype made up of SiC- mosfet s, which volume is 37L that 66% of IGBT-APFs. The results obtained that 380V/75A-SiC-APFs with the control method proposed have a high compensation accuracy (THD<5%) with the grid frequency variations.
- 31 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 10 (4) , 4634-4649
A 380 V/50 kVar SiC-SVG Achieving a Power Density of 1.652 kVar/L With the Optimization of Heatsink and Output Filter Volume
With the rapid development of new energy vehicles, 5G facilities, electric aircraft, and new energy power generation, the high-power-density inverters are developed rapidly. A comprehensive optimization method combining heatsink and inductance filter was proposed in this article. Based on accurate thermal modeling and magnetic modeling, the method proposed chose an optimized switching frequency to minimize the volume of the inverters by compromising the design of the heatsink and inductor volume. Among them, a model of multichip forced air-cooling heatsink was proposed to reduce the size of the heatsink, and the comprehensive thermal resistance error of the proposed model is within 2%. The structure of the grid-connected filter and the inductor model is analyzed showing that the single inductor L-filter has a smaller size and more stability than the LCL-filter at a high switching frequency. The comprehensive optimization method proposed was implemented by 380-V/50-kVar SiC-static var generator (SVG) with the 50-kHz switching frequency, and its topology is a two-level inverter with a single inductor filter. This SiC-SVG reached a volume of 30.2 L (including all components required for mainstream products), which is 50% lower than insulated gate bipolar translator (IGBT)-SVGs. Its efficiency is 98.5% at full load, which is 1.5% higher than IGBT-SVGs. The experiments and temperature rising tests at full load proved the feasibility of the comprehensive optimization method.
- 31 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 10 (4) , 4634-4649
A 380 V/50 kVar SiC-SVG Achieving a Power Density of 1.652 kVar/L With the Optimization of Heatsink and Output Filter Volume
With the rapid development of new energy vehicles, 5G facilities, electric aircraft, and new energy power generation, the high-power-density inverters are developed rapidly. A comprehensive optimization method combining heatsink and inductance filter was proposed in this article. Based on accurate thermal modeling and magnetic modeling, the method proposed chose an optimized switching frequency to minimize the volume of the inverters by compromising the design of the heatsink and inductor volume. Among them, a model of multichip forced air-cooling heatsink was proposed to reduce the size of the heatsink, and the comprehensive thermal resistance error of the proposed model is within 2%. The structure of the grid-connected filter and the inductor model is analyzed showing that the single inductor L-filter has a smaller size and more stability than the LCL-filter at a high switching frequency. The comprehensive optimization method proposed was implemented by 380-V/50-kVar SiC-static var generator (SVG) with the 50-kHz switching frequency, and its topology is a two-level inverter with a single inductor filter. This SiC-SVG reached a volume of 30.2 L (including all components required for mainstream products), which is 50% lower than insulated gate bipolar translator (IGBT)-SVGs. Its efficiency is 98.5% at full load, which is 1.5% higher than IGBT-SVGs. The experiments and temperature rising tests at full load proved the feasibility of the comprehensive optimization method.