Boris Berseneff
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Boris Berseneff has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Adrien Pereira1 shared publication
- Andrea Spinelli
Faculty of Engineering and Applied Science (FEAS), Cranfield University, Bedford MK43 0AL, UK
1 shared publication Bruno Crouzevialle
CEA, Grenoble, France
1 shared publicationC. Kieny
GIE IDEA, France
1 shared publication- G. P. Krupa
Faculty of Engineering and Applied Sciences, Cranfield University, Cranfield, UK
1 shared publication - Igor Cantero
Cegasa Energia S.L.U., 01015 Vitoria, Spain
1 shared publication
Latest Publications
- Open Access
- 5 February 2026
- Published by Elsevier in Journal of Energy Storage
- Vol. 153
Preliminary battery pack design methodology based on interval constraint satisfaction problem resolution and feasible domain analysis
- 5 February 2026
- Published by Elsevier in Journal of Energy Storage
- Vol. 153
Open AccessPreliminary battery pack design methodology based on interval constraint satisfaction problem resolution and feasible domain analysis
- Open Access
- 28 January 2025
- Published by Cambridge University Press (CUP) in The Aeronautical Journal
- Vol. 129 (1335) , 1142-1166
Battery pack technological considerations for hybrid-electric regional aircraft feasibility
This paper presents a study of the effects of the durability and level of energy storage technology on energy management strategies and the performance of hybrid electric turboprops. The results highlight the key role of battery energy density on the durability of the battery pack and the viability of the concept of hybrid electric aircraft. Additionally, the trade-off between zero-day environmental compatibility and battery lifetime is identified, caused by the size of the pack. The effective energy density would decrease with the aging of the cells, leaving a significant inert mass and increasing fuel consumption. Optimal energy management strategies are suggested in light of this new information. Higher specific energy of the pack would mitigate this aspect, along with a reduction in fuel consumption and ${\rm{N}}{{\rm{O}}_{\rm{x}}}$ emissions. Indeed, the improvement of environmental compatibility was found to be nonlinear with a positive rate, suggesting high returns in investing in great improvements in energy density over a gradual increase. This result relates to the results of the statistical technological forecast presented in this study, which, without an increase in funding, predicts the availability of the specific energy required to match the fuel-only baseline in the 2040–2050 decade.- 28 January 2025
- Published by Cambridge University Press (CUP) in The Aeronautical Journal
- Vol. 129 (1335) , 1142-1166
Open AccessBattery pack technological considerations for hybrid-electric regional aircraft feasibility
This paper presents a study of the effects of the durability and level of energy storage technology on energy management strategies and the performance of hybrid electric turboprops. The results highlight the key role of battery energy density on the durability of the battery pack and the viability of the concept of hybrid electric aircraft. Additionally, the trade-off between zero-day environmental compatibility and battery lifetime is identified, caused by the size of the pack. The effective energy density would decrease with the aging of the cells, leaving a significant inert mass and increasing fuel consumption. Optimal energy management strategies are suggested in light of this new information. Higher specific energy of the pack would mitigate this aspect, along with a reduction in fuel consumption and ${\rm{N}}{{\rm{O}}_{\rm{x}}}$ emissions. Indeed, the improvement of environmental compatibility was found to be nonlinear with a positive rate, suggesting high returns in investing in great improvements in energy density over a gradual increase. This result relates to the results of the statistical technological forecast presented in this study, which, without an increase in funding, predicts the availability of the specific energy required to match the fuel-only baseline in the 2040–2050 decade. - Open Access
A Multi-Objective Co-Design Optimization Framework for Grid-Connected Hybrid Battery Energy Storage Systems: Optimal Sizing and Selection of Technology
This paper develops a multi-objective co-design optimization framework for the optimal sizing and selection of battery and power electronics in hybrid battery energy storage systems (HBESSs) connected to the grid. The co-design optimization approach is crucial for such a complex system with coupled subcomponents. To this end, a nondominated sorting genetic algorithm (NSGA-II) is used for optimal sizing and selection of technologies in the design of the HBESS, considering design parameters such as cost, efficiency, and lifetime. The interoperable framework is applied considering three first-life battery cells and one second-life battery cell for forming two independent battery packs as a hybrid battery unit and considers two power conversion architectures for interfacing the hybrid battery unit to the grid with different power stages and levels of modularity. Finally, the globally best HBESS system obtained as the output of the framework is made up of LTO first-life and LFP second-life cells and enables a total cost of ownership (TCO) reduction of 29.6% compared to the baseline.
Open AccessA Multi-Objective Co-Design Optimization Framework for Grid-Connected Hybrid Battery Energy Storage Systems: Optimal Sizing and Selection of Technology
This paper develops a multi-objective co-design optimization framework for the optimal sizing and selection of battery and power electronics in hybrid battery energy storage systems (HBESSs) connected to the grid. The co-design optimization approach is crucial for such a complex system with coupled subcomponents. To this end, a nondominated sorting genetic algorithm (NSGA-II) is used for optimal sizing and selection of technologies in the design of the HBESS, considering design parameters such as cost, efficiency, and lifetime. The interoperable framework is applied considering three first-life battery cells and one second-life battery cell for forming two independent battery packs as a hybrid battery unit and considers two power conversion architectures for interfacing the hybrid battery unit to the grid with different power stages and levels of modularity. Finally, the globally best HBESS system obtained as the output of the framework is made up of LTO first-life and LFP second-life cells and enables a total cost of ownership (TCO) reduction of 29.6% compared to the baseline.
- 6 May 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Instrumentation & Measurement Magazine
- Vol. 17 (2) , 34-40
The significance of energy storage for renewable energy generation and the role of instrumentation and measurement
Energy storage is not a new concept but is gaining importance in the context of the energy transition paradigm. It is expected to play a key role in future electric power systems as the growing development of renewable energy resources and their increasing share in the energy mix introduce significant challenges to the existing power grid due to the high variability of these sources and loads. With competitive energy storage, it will be possible to introduce more flexibility in the electrical system.
- 6 May 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Instrumentation & Measurement Magazine
- Vol. 17 (2) , 34-40
The significance of energy storage for renewable energy generation and the role of instrumentation and measurement
Energy storage is not a new concept but is gaining importance in the context of the energy transition paradigm. It is expected to play a key role in future electric power systems as the growing development of renewable energy resources and their increasing share in the energy mix introduce significant challenges to the existing power grid due to the high variability of these sources and loads. With competitive energy storage, it will be possible to introduce more flexibility in the electrical system.
- 1 June 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Upgraded coordinated voltage control for distribution systems
It is common knowledge that large scale integration of Dispersed Generation (DG) in distribution networks may cause voltage quality problems. But, on the other hand, if correctly controlled it may be able to provide a means of solving these problems. In order to enhance the use of DG, it can be used to perform a coordinated voltage control that would maintain voltage at its set-point value at the substation and some other specific nodes called pilot buses. This function is known as VVC (Voltage Var Control) and is an Advanced Distribution Automation function (ADA) developed for smart grids. The aim of this paper is to propose a new Coordinated Voltage Control for Distribution systems (D-CVC) which uses DCs and Under Load Tap Changer (ULTC). This upgraded D-CVC will be compare with a simpler D-CVC designed in previous works and with the voltage control with only ULTC, which is the current mean of voltage control in most distribution networks.
- 1 June 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Upgraded coordinated voltage control for distribution systems
It is common knowledge that large scale integration of Dispersed Generation (DG) in distribution networks may cause voltage quality problems. But, on the other hand, if correctly controlled it may be able to provide a means of solving these problems. In order to enhance the use of DG, it can be used to perform a coordinated voltage control that would maintain voltage at its set-point value at the substation and some other specific nodes called pilot buses. This function is known as VVC (Voltage Var Control) and is an Advanced Distribution Automation function (ADA) developed for smart grids. The aim of this paper is to propose a new Coordinated Voltage Control for Distribution systems (D-CVC) which uses DCs and Under Load Tap Changer (ULTC). This upgraded D-CVC will be compare with a simpler D-CVC designed in previous works and with the voltage control with only ULTC, which is the current mean of voltage control in most distribution networks.