Brittany N. Diehl
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Brittany N. Diehl has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
Catalina Cabrera
Department of Large Animal Clinical Sciences, College of Veterinary Medicine, University of Florida, Gainesville, FL
3 shared publications- Ahmadreza Mirzaei
Department of Large Animal Clinical Sciences, University of Florida, Gainesville, FL 32611, USA
1 shared publication - Alireza Rahmani Shahraki
Department of Large Animal Clinical Sciences, University of Florida, Gainesville, FL 32611, USA
1 shared publication - Ameer A. Megahed
Department of Animal Medicine (Internal Medicine), Faculty of Veterinary Medicine, Benha University, Moshtohor-Toukh 13736, Egypt
1 shared publication - Ann M. Chan
Department of Pathology Lab Medicine, David Geffen School of Medicine, University of California, Los Angeles, CA 90095, USA
1 shared publication - Catalina Cabrera
College of Veterinary Medicine, University of Florida Department of Large Animal Clinical Sciences Gainesville, Florida
1 shared publication
Latest Publications
- Open Access
Evaluation of the Diagnostic Performance and Validation of an AI-Assisted Fluorescence Imaging Device for Fecal Egg Counts Against the Manual McMaster Reference Method in Kiko Male Goats
Gastrointestinal parasites are a major health and economic concern in small ruminants. The classic microscopic approach using the manual McMaster method serves to quantitatively count parasite eggs, which are labor-intensive and prone to variation. Artificial intelligence-based systems (Parasight®, powered by Fecalsight AI™) could provide quicker and more objective alternatives; therefore, independent validation is necessary before clinical implementation. The objective of this study was to evaluate the agreement, classification consistency, and diagnostic performance of Parasight® relative to the manual McMaster method, with a focus on its suitability as a screening and decision-support tool. Fecal samples from 44 Kiko goats over 3 sampling times were analyzed using both methods, with manual counts performed independently by 2 observers. Agreement between methods was assessed using Lin’s concordance correlation coefficient, Bland–Altman analysis, and Cohen’s Kappa for categorical classification. Diagnostic performance for identifying animals exceeding the clinical treatment threshold (>1000 eggs per gram) was evaluated using receiver operating characteristic (ROC) analysis, and regression modeling was used to characterize associations between methods. Manual observers showed high reliability, confirming the suitability of the McMaster method as a reference. Compared with manual counts, Parasight® consistently underestimated egg counts, resulting in poor-to-moderate absolute agreement; however, it reliably ranked animals by parasite burden and showed excellent discrimination for identifying animals above the treatment threshold (AUC = 0.90–0.96). Regression analyses further demonstrated linear or curvilinear associations depending on egg counts. Overall, the Parasight® device reliably captured relative parasite burden but required a lower operational threshold to match manual treatment decisions.
Open AccessEvaluation of the Diagnostic Performance and Validation of an AI-Assisted Fluorescence Imaging Device for Fecal Egg Counts Against the Manual McMaster Reference Method in Kiko Male Goats
Gastrointestinal parasites are a major health and economic concern in small ruminants. The classic microscopic approach using the manual McMaster method serves to quantitatively count parasite eggs, which are labor-intensive and prone to variation. Artificial intelligence-based systems (Parasight®, powered by Fecalsight AI™) could provide quicker and more objective alternatives; therefore, independent validation is necessary before clinical implementation. The objective of this study was to evaluate the agreement, classification consistency, and diagnostic performance of Parasight® relative to the manual McMaster method, with a focus on its suitability as a screening and decision-support tool. Fecal samples from 44 Kiko goats over 3 sampling times were analyzed using both methods, with manual counts performed independently by 2 observers. Agreement between methods was assessed using Lin’s concordance correlation coefficient, Bland–Altman analysis, and Cohen’s Kappa for categorical classification. Diagnostic performance for identifying animals exceeding the clinical treatment threshold (>1000 eggs per gram) was evaluated using receiver operating characteristic (ROC) analysis, and regression modeling was used to characterize associations between methods. Manual observers showed high reliability, confirming the suitability of the McMaster method as a reference. Compared with manual counts, Parasight® consistently underestimated egg counts, resulting in poor-to-moderate absolute agreement; however, it reliably ranked animals by parasite burden and showed excellent discrimination for identifying animals above the treatment threshold (AUC = 0.90–0.96). Regression analyses further demonstrated linear or curvilinear associations depending on egg counts. Overall, the Parasight® device reliably captured relative parasite burden but required a lower operational threshold to match manual treatment decisions.
- 1 July 2023
- Published by American Veterinary Medical Association (AVMA) in Journal of the American Veterinary Medical Association
- Vol. 261 (7) , 1-3
Peripheral lymphadenopathy in twin male Brahman calves
"Peripheral lymphadenopathy in twin male Brahman calves" published on 17 Mar 2023 by American Veterinary Medical Association.
- 1 July 2023
- Published by American Veterinary Medical Association (AVMA) in Journal of the American Veterinary Medical Association
- Vol. 261 (7) , 1-3
Peripheral lymphadenopathy in twin male Brahman calves
"Peripheral lymphadenopathy in twin male Brahman calves" published on 17 Mar 2023 by American Veterinary Medical Association.
- Open Access
Analytical Validation of the IMMULITE® 2000 XPi Progesterone Assay for Quantitative Analysis in Ovine Serum
Monitoring circulating progesterone (P4) concentration is an important component of basic and applied reproduction research and clinical settings. IMMULITE® 2000 XPi (Siemens) is a newly upgraded fully automated immunoassay system marketed for human use to measure concentrations of different analytes including P4. Our objective was therefore to characterize the analytical performance of the IMMULITE® 2000 XPi P4 immunoassay across the reportable range in ovine serum. This validation of analytical performance included determining (1) linearity, (2) precision through within-run, and between-run coefficient of variation (CV) calculations, (3) accuracy through bias calculations for spiking-recovery bias and interlaboratory (range and average based) bias for two laboratories across the reportable range (0.2–40 ng/mL). The average within-run and between-run precision (CV%) across the reportable range of the IMMULITE® 2000 XPi P4 immunoassay for serum P4 concentration were both ® 2000 XPi P4 immunoassay provides a precise, accurate, reliable, and safe method for measuring P4 concentration ovine serum.
Open AccessAnalytical Validation of the IMMULITE® 2000 XPi Progesterone Assay for Quantitative Analysis in Ovine Serum
Monitoring circulating progesterone (P4) concentration is an important component of basic and applied reproduction research and clinical settings. IMMULITE® 2000 XPi (Siemens) is a newly upgraded fully automated immunoassay system marketed for human use to measure concentrations of different analytes including P4. Our objective was therefore to characterize the analytical performance of the IMMULITE® 2000 XPi P4 immunoassay across the reportable range in ovine serum. This validation of analytical performance included determining (1) linearity, (2) precision through within-run, and between-run coefficient of variation (CV) calculations, (3) accuracy through bias calculations for spiking-recovery bias and interlaboratory (range and average based) bias for two laboratories across the reportable range (0.2–40 ng/mL). The average within-run and between-run precision (CV%) across the reportable range of the IMMULITE® 2000 XPi P4 immunoassay for serum P4 concentration were both ® 2000 XPi P4 immunoassay provides a precise, accurate, reliable, and safe method for measuring P4 concentration ovine serum.
- 1 October 2022
- Published by American Veterinary Medical Association (AVMA) in Journal of the American Veterinary Medical Association
- Vol. 260 (13) , 1647-1649
Theriogenology Question of the Month
"Theriogenology Question of the Month" published on 17 Aug 2022 by American Veterinary Medical Association.
- 1 October 2022
- Published by American Veterinary Medical Association (AVMA) in Journal of the American Veterinary Medical Association
- Vol. 260 (13) , 1647-1649
Theriogenology Question of the Month
"Theriogenology Question of the Month" published on 17 Aug 2022 by American Veterinary Medical Association.
- 1 October 2022
- Published by American Veterinary Medical Association (AVMA) in Journal of the American Veterinary Medical Association
- Vol. 260 (13) , 1634-1636
What Is Your Diagnosis?
"What Is Your Diagnosis?" published on 20 Jul 2022 by American Veterinary Medical Association.
- 1 October 2022
- Published by American Veterinary Medical Association (AVMA) in Journal of the American Veterinary Medical Association
- Vol. 260 (13) , 1634-1636
What Is Your Diagnosis?
"What Is Your Diagnosis?" published on 20 Jul 2022 by American Veterinary Medical Association.