Riece Koniman
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Riece Koniman has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
Manish Kaushik
Department of Renal Medicine, Singapore General Hospital, Singapore 169608, Singapore
3 shared publicationsHan Khim Tan
Department of Renal Medicine Singapore General Hospital Singapore Singapore
2 shared publicationsSu Hooi Teo
Department of Renal Medicine Singapore General Hospital Singapore Singapore
2 shared publicationsBien Keem Tan
Department of Plastic, Reconstructive & Aesthetic Surgery, Singapore General Hospital, Singapore
1 shared publicationChandramouli Nagarajan
Department of Haematology Singapore General Hospital Singapore Singapore
1 shared publicationChee Wooi Tan
Department of Renal Medicine, Singapore General Hospital, Singapore
1 shared publication
Latest Publications
- 7 March 2024
- Published by SAGE Publications in Peritoneal Dialysis International: Journal of the International Society for Peritoneal Dialysis
- Vol. 44 (6) , 413-418
Rapid point-of-care test for diagnosis of peritonitis in peritoneal dialysis patients
Background: Periplex® is a rapid point-of-care test based on the detection of interleukin-6 (IL-6) or matrix metalloproteinase-8 (MMP-8) to diagnose peritonitis in peritoneal dialysis (PD) patients. Methods: This single-centre study was conducted in Singapore General Hospital from 2019 to 2022. The study recruited PD patients suspected of having peritonitis. Periplex was performed at the presentation and recovery of peritonitis. Primary outcomes were sensitivity and specificity of Periplex at presentation. The positive and negative predictive values of tests were also performed. Results: A total of 120 patients were included in the study. The mean age was 60.9 ± 14.9 years, 53% were male, 79% were Chinese and 47.5% had diabetes mellitus. Periplex was positive in all patients with peritonitis ( n = 114); sensitivity of 100%; 95% confidence interval (CI): 100–100%. Periplex was falsely positive in three patients with non-infective eosinophilic peritonitis, resulting in a low specificity of 50%; 95% CI: 41.1–59.0%. Periplex had a positive predictive value of 97.4% and a negative predictive value of 100%. During recovery from peritonitis, Periplex had high specificity (93.6%) and negative predictive value (98.7%) to indicate the resolution of infection. MMP-8 was more sensitive than IL-6 in detecting peritonitis. Periplex was positive in all patients with peritonitis regardless of the types of PD solutions used. Conclusions: Periplex had high sensitivity, and positive and negative predictive values in the diagnosis of peritonitis can be considered as a screening tool for peritonitis. Given its high specificity and negative predictive value, it may also be used to document the resolution of peritonitis.
- 7 March 2024
- Published by SAGE Publications in Peritoneal Dialysis International: Journal of the International Society for Peritoneal Dialysis
- Vol. 44 (6) , 413-418
Rapid point-of-care test for diagnosis of peritonitis in peritoneal dialysis patients
Background: Periplex® is a rapid point-of-care test based on the detection of interleukin-6 (IL-6) or matrix metalloproteinase-8 (MMP-8) to diagnose peritonitis in peritoneal dialysis (PD) patients. Methods: This single-centre study was conducted in Singapore General Hospital from 2019 to 2022. The study recruited PD patients suspected of having peritonitis. Periplex was performed at the presentation and recovery of peritonitis. Primary outcomes were sensitivity and specificity of Periplex at presentation. The positive and negative predictive values of tests were also performed. Results: A total of 120 patients were included in the study. The mean age was 60.9 ± 14.9 years, 53% were male, 79% were Chinese and 47.5% had diabetes mellitus. Periplex was positive in all patients with peritonitis ( n = 114); sensitivity of 100%; 95% confidence interval (CI): 100–100%. Periplex was falsely positive in three patients with non-infective eosinophilic peritonitis, resulting in a low specificity of 50%; 95% CI: 41.1–59.0%. Periplex had a positive predictive value of 97.4% and a negative predictive value of 100%. During recovery from peritonitis, Periplex had high specificity (93.6%) and negative predictive value (98.7%) to indicate the resolution of infection. MMP-8 was more sensitive than IL-6 in detecting peritonitis. Periplex was positive in all patients with peritonitis regardless of the types of PD solutions used. Conclusions: Periplex had high sensitivity, and positive and negative predictive values in the diagnosis of peritonitis can be considered as a screening tool for peritonitis. Given its high specificity and negative predictive value, it may also be used to document the resolution of peritonitis.
- Open Access
- 1 December 2023
- Published by Xia & He Publishing in Journal of Translational Critical Care Medicine
- Vol. 5 (4)
Therapeutic plasma exchange in critical illness
Therapeutic plasma exchange (TPE) is widely used for various diseases, particularly in critically ill patients. Most of these indications rely mainly on the removal of pathological molecules in the plasma by TPE. TPE is also used to replace missing plasma components in some diseases. However, there are emerging data on the use of TPE in novel indications because of its potential immunomodulatory effects. This review discusses the techniques of TPE, key considerations when prescribing TPE, indications for TPE in critically ill patients, emerging developments and knowledge gaps in this field.
- 1 December 2023
- Published by Xia & He Publishing in Journal of Translational Critical Care Medicine
- Vol. 5 (4)
Open AccessTherapeutic plasma exchange in critical illness
Therapeutic plasma exchange (TPE) is widely used for various diseases, particularly in critically ill patients. Most of these indications rely mainly on the removal of pathological molecules in the plasma by TPE. TPE is also used to replace missing plasma components in some diseases. However, there are emerging data on the use of TPE in novel indications because of its potential immunomodulatory effects. This review discusses the techniques of TPE, key considerations when prescribing TPE, indications for TPE in critically ill patients, emerging developments and knowledge gaps in this field.
- 15 July 2022
- Published by Wiley in Seminars in Dialysis
- Vol. 36 (1) , 12-17
The use of medium cutoff dialyzers in patients with multiple myeloma and acute kidney injury requiring hemodialysis: A systematic review
Background: Patients with multiple myeloma and high serum levels of circulating free light chains (FLC) have increased risk of acute kidney injury (AKI) secondary to cast nephropathy and is associated with poor survival. Despite removal of FLC by medium cutoff (MCO) dialyzer, the role of MCO hemodialysis (HD) in the treatment of cast nephropathy and its clinical benefits remain unknown. Methods: A systematic review was conducted to establish the effectiveness of MCO dialyzer and clinical outcomes, compared to other forms of dialyzers in the removal of FLC, in myeloma patients with AKI. The primary outcome was effectiveness of MCO-HD in reducing serum FLC. The secondary outcomes were HD independence, estimated glomerular filtrate rate, mortality rates, length of hospitalization, rebound of serum FLC before the next dialysis, removal of other molecules during dialysis, and adverse events. Results: We identified three case series, with a total of 17 patients. There were no randomized controlled trials (RCTs) or cohort studies. These case series showed that MCO dialyzer was effective in the removal of FLC and led to a reduction in FLC concentration post-dialysis. The majority of the case series did not have comparator arm and renal and/or other clinical outcomes. Conclusion: MCO dialyzer appeared to be effective in the removal of FLC based on the existing limited data. However, more data, particularly large-scale RCTs, are needed to assess the use of MCO dialyzer in reducing serum FLC and its effect on clinical outcomes in patients with multiple myeloma and AKI.
- 15 July 2022
- Published by Wiley in Seminars in Dialysis
- Vol. 36 (1) , 12-17
The use of medium cutoff dialyzers in patients with multiple myeloma and acute kidney injury requiring hemodialysis: A systematic review
Background: Patients with multiple myeloma and high serum levels of circulating free light chains (FLC) have increased risk of acute kidney injury (AKI) secondary to cast nephropathy and is associated with poor survival. Despite removal of FLC by medium cutoff (MCO) dialyzer, the role of MCO hemodialysis (HD) in the treatment of cast nephropathy and its clinical benefits remain unknown. Methods: A systematic review was conducted to establish the effectiveness of MCO dialyzer and clinical outcomes, compared to other forms of dialyzers in the removal of FLC, in myeloma patients with AKI. The primary outcome was effectiveness of MCO-HD in reducing serum FLC. The secondary outcomes were HD independence, estimated glomerular filtrate rate, mortality rates, length of hospitalization, rebound of serum FLC before the next dialysis, removal of other molecules during dialysis, and adverse events. Results: We identified three case series, with a total of 17 patients. There were no randomized controlled trials (RCTs) or cohort studies. These case series showed that MCO dialyzer was effective in the removal of FLC and led to a reduction in FLC concentration post-dialysis. The majority of the case series did not have comparator arm and renal and/or other clinical outcomes. Conclusion: MCO dialyzer appeared to be effective in the removal of FLC based on the existing limited data. However, more data, particularly large-scale RCTs, are needed to assess the use of MCO dialyzer in reducing serum FLC and its effect on clinical outcomes in patients with multiple myeloma and AKI.