GCGeorge C. Y. Chan

George C. Y. Chan

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


George C. Y. Chan has a total of 62 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Landmark Publications in Analytical Atomic Spectrometry: Fundamentals and Instrumentation Development

    by George C.-Y. Chan, Gary M. Hieftje, Nicoló Omenetto, Ove Axner, Arne Bengtson, Nicolas H. Bings, Michael W. Blades, Annemie Bogaerts, Mikhail A. Bolshov, José A.C. Broekaert, et al.

    The almost-two-centuries history of spectrochemical analysis has generated a body of literature so vast that it has become nearly intractable for experts, much less for those wishing to enter the field. Authoritative, focused reviews help to address this problem but become so granular that the overall directions of the field are lost. This broader perspective can be provided partially by general overviews but then the thinking, experimental details, theoretical underpinnings, and instrumental innovations of the original work must be sacrificed. In the present compilation, this dilemma is overcome by assembling the most impactful publications in the area of analytical atomic spectrometry. Each entry was proposed by at least one current expert in the field and supported by a narrative that justifies its inclusion. The entries were then assembled into a coherent sequence and returned to contributors for a round-robin review. A total of 48 scientists participated in this endeavor, contributing a combined list of 1055 individual articles spanning 17 sub-disciplines of spectrochemical analysis into what the current community views as “key” publications. Of these cited articles, 60 received nominations from four or more scientists, establishing them as the most indispensable reading materials. The outcome of this collaborative effort is intended to serve as a valuable resource not only for current practitioners in atomic spectroscopy but also for present and future students who represent coming generations of analytical atomic spectroscopists.


  • Characterization of a Low-Temperature Plasma (LTP) Ambient Ionization Source Using Temporally Resolved Monochromatic Imaging Spectrometry

    by George C.-Y. Chan, Carsten Engelhard, Joshua S. Wiley, Ayanna U. Shoulds, R. Graham Cooks, Gary M. Hieftje, Jacob T. Shelley

    The low-temperature plasma (LTP) probe is a common plasma-based source used for ambient desorption–ionization mass spectrometry (MS). While the LTP probe has been characterized in detail with MS, relatively few studies have used optical spectroscopy. In this paper, two-dimensional (2D) imaging at selected wavelengths is used to visualize important species in the LTP plasma jet. First, 2D steady-state images of the LTP plume for N 2 + (391.2 nm), He I (706.5 nm), and N 2 (337.1 nm) emissions were recorded under selected plasma conditions. Second, time-resolved 2D emission maps of radiative species in the LTP plasma jet were recorded through the use of a 200 ns detection gate and varying gate delays with respect to the LTP trigger pulse. Emission from He I, N 2 + , and N 2 in the plasma jet region was found to show a transient behavior (often referred to as plasma bullets) lasting only a few microseconds. The N 2 + and He I maps were highly correlated in spatial and temporal structure. Further, emission from N 2 showed two maxima in time, one before and one after the maximum emission for N 2 + and He I, due to an initial electronic excitation wave and ion–electron recombination, respectively. Third, the interaction of the LTP probe with a sample substrate and an electrically grounded metallic needle was studied. Emission from a fluorophore on the sample substrate showed an initial photon-induced excitation from plasma-generated photons followed by electronic excitation by other plasma species. The presence of a grounded needle near the plasma jet significantly extended the plasma jet lifetime and also generated a long-lived corona discharge on the needle. The effect of LTP operating parameters on emission spectra was correlated with mass-spectral results including reagent-ion signals. Lastly, five movies provide a side-by-side comparison of the temporal behavior of emitting species and insights into the interactions of the emission clouds with a sample surface as well as an external needle. Temporally and spatially resolved imaging provided insights into important processes in the LTP plasma jet, which will help improve analyte ion sampling in LTP–MS.


  • Characterization and Optimization of a Spectral Window for Direct Gaseous Uranium Hexafluoride Enrichment Assay Using Laser-Induced Breakdown Spectroscopy

    by George C. Y. Chan, Leigh R. Martin, Richard E. Russo

    Through a systematic scanning of 235 U and 238 U emission lines between 280 nm and 745 nm, the optimal emission line for direct gaseous uranium hexafluoride (UF 6 ) enrichment assay using laser-induced breakdown spectroscopy (LIBS) was found. Screening for spectral features that are potentially useful for U isotopic analysis was gauged from the magnitude of the 235 U– 238 U isotopic shift and the signal-to-background ratio of the emission line through a parameter termed ΔSBR 235U – 238U . The ΔSBR spectrum shows peaks at wavelength positions where there are strong lines with significant 235 U– 238 U shifts. The screening identified 13 spectral-window candidates, which were down selected based on their overall accuracy in predicting the 235 U enrichment of three UF 6 samples of natural (0.720 atom% 235 U) and low-enriched (4.675 atom% and 9.157 atom% 235 U) grades. The U(I) 646.498 nm emission line, with a determined 235 U– 238 U isotopic shift of −17.7 pm, was found to be the optimal spectral window for direct UF 6 enrichment assay. The root mean square error for enrichment assays on the three natural and low-enriched UF 6 samples, with each sample measured in six replicates, was 0.31% in absolute 235 U content. Each measurement comprised LIBS signals accumulated from 3000 laser shots. The analytical bias and precision were better than 0.5% and 0.3%, respectively, in absolute [ 235 U/( 235 U + 238 U)] ratios. Specific for the two low-enriched UF 6 samples, the relative standard deviations from six replicated measurements were around 2%.


  • Direct uranium enrichment assay in gaseous uranium hexafluoride with laser induced breakdown spectroscopy

    by George C.-Y. Chan, Xianglei Mao, Leigh R. Martin, Lee D. Trowbridge, Richard E. Russo


  • Internal mixing dynamics of Cu/Sn-Pb plasmas produced by femtosecond laser ablation

    by Ran Hai, Xianglei Mao, George C.-Y. Chan, Richard E. Russo, Hongbin Ding, Vassilia Zorba


  • Fundamental characteristics of plasma-related matrix-effect cross-over points in inductively coupled plasma-atomic emission spectrometry

    by George C.-Y. Chan, Gary M. Hieftje

    The dependence of matrix-effect cross-over locations on plasma operating conditions (central-channel gas flow, plasma forward power, and dry/wet plasma), excitation potentials of emission lines, and matrix properties was explored. Improving plasma robustness either by lowering the central-channel gas flow rate, by increasing the plasma forward power or by employing a plasma torch with a larger injector diameter either does not significantly reduce or occasionally only slightly reduces the depressive matrix effect in the normal analytical zone (NAZ) of the plasma caused by matrix elements with a low second ionization potential. Aqueous aerosols were found to have a large impact on the location of the cross-over point; cross-over locations can be 7 mm apart when dry and wet plasma conditions are used. Further, the location of a cross-over point is sandwiched between the peak emission locations of “soft” and “hard” emission lines, which correspond to thermal and non-thermal regions of the plasma, respectively. Cross-over points were found to shift downward almost linearly with increasing first ionization potentials of the matrices. The first ionization potential of the matrix was found also to be the prime parameter that defines the magnitude of emission enhancement low in the plasma. In contrast, it is the second ionization potential of the matrix element that dictates the magnitude of signal depression high in the plasma. The locations of cross-over points correlate strongly with the magnitude of the depression in the normal analytical zone of the plasma. In addition, the mechanism(s) responsible for this depressive effect was found to be operative at all vertical heights in the plasma, including the emission enhancement region low in the discharge.