Hui Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hui Chen has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Jinjun Liu
State Key Laboratory of Electrical Insulation and Power Equipment, School of Electrical Engineering, Xian Jiaotong University, Xian, China
3 shared publications - Cong Li
State Key Laboratory of Electrical Insulation and Power Equipment, School of Electrical Engineering, Xian Jiaotong University, Xian, China
2 shared publications - Sixing Du
School of Electrical Engineering, Xian Jiaotong University, Xian, China
2 shared publications - Hengkai Dang
State Key Laboratory of Electrical Insulation and Power Equipment, School of Electrical Engineering, Xian Jiaotong University, Xian, China
1 shared publication - Ning Guo
State Key Laboratory of Electrical Insulation and Power Equipment, School of Electrical Engineering, Xian Jiaotong University, Xian, China
1 shared publication - Shaodi Ouyang
School of Electrical Engineering, Xi'an Jiaotong University, Xi'an China 710049
1 shared publication
Latest Publications
- 6 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (5) , 7042-7057
Design Methodology of Three-Phase LLC Charger Based on Time-Domain Model With Enhanced Analytical Accuracy and Power Efficiency
Three-phase LLC converters show considerable potential in battery chargers. However, the existing parameter design methods for three-phase LLC converters have limitation in analytical accuracy and efficiency optimization over the wide voltage range. To address the above issues, this article proposes a time-domain model (TDM) based design method for three-phase LLC chargers. First, a comprehensive TDM for the three-phase LLC converter is developed, providing a detailed analysis of operating modes and mode distributions across the entire operating range. Then, based on TDM, a novel design method is proposed to optimize the efficiency of the entire charging process. The resonant root-mean-square current is selected as the optimization objective, and its relationship with design parameters is researched to derive the optimal constraints. Meanwhile, suitable operating modes are identified for each charging pattern to satisfy the soft-switching condition. A step-by-step design procedure is finally provided to determine the optimal parameters. The analysis proves that the proposed design methodology enhances accuracy and efficiency across the entire operating range of the three-phase LLC charger. The effectiveness is also validated through a 4.5-kW experimental setup with 98.1% peak efficiency.
- 6 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (5) , 7042-7057
Design Methodology of Three-Phase LLC Charger Based on Time-Domain Model With Enhanced Analytical Accuracy and Power Efficiency
Three-phase LLC converters show considerable potential in battery chargers. However, the existing parameter design methods for three-phase LLC converters have limitation in analytical accuracy and efficiency optimization over the wide voltage range. To address the above issues, this article proposes a time-domain model (TDM) based design method for three-phase LLC chargers. First, a comprehensive TDM for the three-phase LLC converter is developed, providing a detailed analysis of operating modes and mode distributions across the entire operating range. Then, based on TDM, a novel design method is proposed to optimize the efficiency of the entire charging process. The resonant root-mean-square current is selected as the optimization objective, and its relationship with design parameters is researched to derive the optimal constraints. Meanwhile, suitable operating modes are identified for each charging pattern to satisfy the soft-switching condition. A step-by-step design procedure is finally provided to determine the optimal parameters. The analysis proves that the proposed design methodology enhances accuracy and efficiency across the entire operating range of the three-phase LLC charger. The effectiveness is also validated through a 4.5-kW experimental setup with 98.1% peak efficiency.
- 11 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 38 (11) , 14178-14194
A T-Type DAB-Based Isolated DC-DC-AC Three-Port Converter With High Power Efficiency
This article proposes a high-efficiency isolated dc-dc-ac three-port converter (TPC) intended for residential photovoltaic-battery systems. The TPC is derived from a DAB-based dc-ac converter. Its dc-side provides two bidirectional dc ports by sharing the full-bridge topology, while its ac-side enables direct ac-load connection via a unique T-type half-bridge structure. Due to the shared branches and T-type topology, the proposed TPC has few components but offers single-stage power conversion and substantial control degrees of freedom (CDF). Sufficient CDFs facilitate the TPC to maintain high efficiency when performing decoupled power flow control among the three ports. To maximize the benefits of sufficient CDFs, a pulsewidth modulation (PWM) plus triple-phase-shift (TPS) modulation scheme based on these CDFs is presented. PWM is employed to control the dc-dc power flow while TPS is used to regulate the dc-ac power flow. Benefiting from the TPS optimization, this TPC features low rms current and excellent soft-switching performance. Compared to state-of-the-art, the efficiency of the proposed TPC is improved by up to 1% under the proposed modulation scheme. The effectiveness of the proposed TPC is verified by a 220-V 500-W experimental setup.
- 11 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 38 (11) , 14178-14194
A T-Type DAB-Based Isolated DC-DC-AC Three-Port Converter With High Power Efficiency
This article proposes a high-efficiency isolated dc-dc-ac three-port converter (TPC) intended for residential photovoltaic-battery systems. The TPC is derived from a DAB-based dc-ac converter. Its dc-side provides two bidirectional dc ports by sharing the full-bridge topology, while its ac-side enables direct ac-load connection via a unique T-type half-bridge structure. Due to the shared branches and T-type topology, the proposed TPC has few components but offers single-stage power conversion and substantial control degrees of freedom (CDF). Sufficient CDFs facilitate the TPC to maintain high efficiency when performing decoupled power flow control among the three ports. To maximize the benefits of sufficient CDFs, a pulsewidth modulation (PWM) plus triple-phase-shift (TPS) modulation scheme based on these CDFs is presented. PWM is employed to control the dc-dc power flow while TPS is used to regulate the dc-ac power flow. Benefiting from the TPS optimization, this TPC features low rms current and excellent soft-switching performance. Compared to state-of-the-art, the efficiency of the proposed TPC is improved by up to 1% under the proposed modulation scheme. The effectiveness of the proposed TPC is verified by a 220-V 500-W experimental setup.
- 21 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 37 (12) , 14343-14361
An Asymmetrical Phase-Shift Scheme of Three-Phase Dual Active Bridge With Minimum Current Root-Mean-Square Value Control
The three-phase dual active bridge (3ph-DAB) converter is a promising topology attracting increasing attention. However, because it is limited to symmetrical three-phase bridge control, the conventional single-phase-shift control method (SPS) remains the most common method for 3ph-DAB converter. The obvious shortcomings of SPS control include the soft-switching failure, massive circulating energy, and high root-mean-square (rms) current value at the light load, particularly with large voltage variation-ratio conditions. To overcome these drawbacks, this article proposes a novel asymmetrical phase shift (APS) control strategy. Unlike other optimized modulation schemes, this optimized strategy breaks the symmetrical control rules of three-phase bridges by introducing variable phase-shift angles among three-phase legs. The novel APS control strategy can substantially reduce the current's rms value and extend the soft-switching operation range due to these additional phase-shift angles. Further, the analytical solutions for the optimal phase-shift angles are derived by solving the global optimal condition equations. Analytical solutions, compared with complex numerical solutions derived by other optimized schemes, can be easily adopted in digital implementation and perform well under changing parameter conditions. Finally, experimental results verify the outstanding performance of the proposed modulation strategy.
- 21 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 37 (12) , 14343-14361
An Asymmetrical Phase-Shift Scheme of Three-Phase Dual Active Bridge With Minimum Current Root-Mean-Square Value Control
The three-phase dual active bridge (3ph-DAB) converter is a promising topology attracting increasing attention. However, because it is limited to symmetrical three-phase bridge control, the conventional single-phase-shift control method (SPS) remains the most common method for 3ph-DAB converter. The obvious shortcomings of SPS control include the soft-switching failure, massive circulating energy, and high root-mean-square (rms) current value at the light load, particularly with large voltage variation-ratio conditions. To overcome these drawbacks, this article proposes a novel asymmetrical phase shift (APS) control strategy. Unlike other optimized modulation schemes, this optimized strategy breaks the symmetrical control rules of three-phase bridges by introducing variable phase-shift angles among three-phase legs. The novel APS control strategy can substantially reduce the current's rms value and extend the soft-switching operation range due to these additional phase-shift angles. Further, the analytical solutions for the optimal phase-shift angles are derived by solving the global optimal condition equations. Analytical solutions, compared with complex numerical solutions derived by other optimized schemes, can be easily adopted in digital implementation and perform well under changing parameter conditions. Finally, experimental results verify the outstanding performance of the proposed modulation strategy.