Mifang Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Mifang Li has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Yibiao Liu
Longgang Central Hospital of Shenzhen, Shenzhen 518116, China
3 shared publications - Lingyan Zhang
Shenzhen Clinical Medical College, Guangzhou University of Chinese Medicine (Longgang Central Hospital of Shenzhen), Shenzhen, China
2 shared publications - Mingliang Ma
Shanghai Engineering Research Center of Molecular Therapeutics and New Drug Development, School of Chemistry and Molecular Engineering, East China Normal University, Shanghai 200062, China
1 shared publication - Qiong Liu
Shenzhen Key Laboratory of Marine Biotechnology and Ecology, College of Life Sciences and Oceanography, Shenzhen University, Shenzhen, China
1 shared publication - Tailin Xu
The Institute for Advanced Study (IAS), Shenzhen University, Shenzhen, 518060, China
1 shared publication - Xinai Han
Department of Rheumatology and Immunology, The Third Affiliated Hospital of Southern Medical University, Guangzhou, China
1 shared publication
Latest Publications
- Open Access
- 25 July 2023
- Published by MDPI AG in Biosensors
- Vol. 13 (8) , 758
Vertical Graphene-Based Printed Electrochemical Biosensor for Simultaneous Detection of Four Alzheimer’s Disease Blood Biomarkers
Early detection and timely intervention play a vital role in the effective management of Alzheimer’s disease. Currently, the diagnostic accuracy for Alzheimer’s disease based on a single blood biomarker is relatively low, and the combined use of multiple blood biomarkers can greatly improve diagnostic accuracy. Herein, we report a printed electrochemical biosensor based on vertical graphene (VG) modified with gold nanoparticles (VG@nanoAu) for the simultaneous detection of four Alzheimer’s disease blood biomarkers. The printed electrochemical electrode array was constructed by laser etching and inkjet printing. Then gold nanoparticles were modified onto the working electrode surface via electrodeposition to further improve the sensitivity of the sensor. In addition, the entire printed electrochemical sensing system incorporates an electrochemical micro-workstation and a smartphone. The customized electrochemical micro-workstation incorporates four electro-chemical control chips, enabling the sensor to simultaneously analyze four biomarkers. Consequently, the printed electrochemical sensing system exhibits excellent analytical performance due to the large surface area, biocompatibility, and good conductivity of VG@nanoAu. The detection limit of the sensing system for Aβ40, Aβ42, T-tau, and P-tau181 was 0.072, 0.089, 0.071, and 0.051 pg/mL, respectively, which meets the detection requirements of Alzheimer’s disease blood biomarkers. The printed electrochemical sensing system also exhibits good specificity and stability. This work has great value and promising prospects for early Alzheimer’s disease diagnosis using blood biomarkers.
- 25 July 2023
- Published by MDPI AG in Biosensors
- Vol. 13 (8) , 758
Open AccessVertical Graphene-Based Printed Electrochemical Biosensor for Simultaneous Detection of Four Alzheimer’s Disease Blood Biomarkers
Early detection and timely intervention play a vital role in the effective management of Alzheimer’s disease. Currently, the diagnostic accuracy for Alzheimer’s disease based on a single blood biomarker is relatively low, and the combined use of multiple blood biomarkers can greatly improve diagnostic accuracy. Herein, we report a printed electrochemical biosensor based on vertical graphene (VG) modified with gold nanoparticles (VG@nanoAu) for the simultaneous detection of four Alzheimer’s disease blood biomarkers. The printed electrochemical electrode array was constructed by laser etching and inkjet printing. Then gold nanoparticles were modified onto the working electrode surface via electrodeposition to further improve the sensitivity of the sensor. In addition, the entire printed electrochemical sensing system incorporates an electrochemical micro-workstation and a smartphone. The customized electrochemical micro-workstation incorporates four electro-chemical control chips, enabling the sensor to simultaneously analyze four biomarkers. Consequently, the printed electrochemical sensing system exhibits excellent analytical performance due to the large surface area, biocompatibility, and good conductivity of VG@nanoAu. The detection limit of the sensing system for Aβ40, Aβ42, T-tau, and P-tau181 was 0.072, 0.089, 0.071, and 0.051 pg/mL, respectively, which meets the detection requirements of Alzheimer’s disease blood biomarkers. The printed electrochemical sensing system also exhibits good specificity and stability. This work has great value and promising prospects for early Alzheimer’s disease diagnosis using blood biomarkers.
- Open Access
- 20 September 2022
- Published by MDPI AG in Pharmaceutics
- Vol. 14 (10) , 1988
Multifunctional Polydopamine-Based Nanoparticles for Dual-Mode Imaging Guided Targeted Therapy of Lupus Nephritis
Lupus nephritis (LN) is a common and refractory inflammation of the kidneys caused by systemic lupus erythematosus. Diagnosis and therapies at this stage are inefficient or have severe side effects. In recent years, nanomedicines show great potential for imaging diagnosis and controlled drug release. Herein, we developed a polydopamine (PDA)-based nanocarrier modified with Fe3O4 and Pt nanoparticles and loaded with necrostatin-1 (Nec-1) for the bimodal imaging and therapy of LN. Results demonstrate that Nec-1/PDA@Pt-Fe3O4 nanocarrier exhibits good biocompatibility. Nec-1, as an inhibitor of receptor-interacting protein 1 kinase, can be used to inhibit receptor-interacting protein 1 kinase activity and then reduces inflammation due to LN. Experiments in vitro and in the LN mouse model confirmed that the nanocarrier can reduce neutrophil extracellular traps (NETs) production by RIPK1 and alleviate the progression of inflammation. Previous studies proved that Pt nanoparticles can catalyze H2O2 to produce oxygen. A blood oxygen graph of mouse photoacoustic tomography confirmed that Nec-1/PDA@Pt-Fe3O4 can generate oxygen to fight against the hypoxic microenvironment of LN. PDA and Fe3O4 are used as photographic developers for photoacoustic or magnetic resonance imaging. The preliminary imaging results support Nec-1/PDA@Pt-Fe3O4 potential for photoacoustic/magnetic resonance dual-mode imaging, which can accurately and non-invasively monitor microscopic changes due to diseases. Nec-1/PDA@Pt-Fe3O4 combining these advantages exhibited outstanding performance in LN imaging and therapy. This work offers valuable insights into LN diagnosis and therapy.
- 20 September 2022
- Published by MDPI AG in Pharmaceutics
- Vol. 14 (10) , 1988
Open AccessMultifunctional Polydopamine-Based Nanoparticles for Dual-Mode Imaging Guided Targeted Therapy of Lupus Nephritis
Lupus nephritis (LN) is a common and refractory inflammation of the kidneys caused by systemic lupus erythematosus. Diagnosis and therapies at this stage are inefficient or have severe side effects. In recent years, nanomedicines show great potential for imaging diagnosis and controlled drug release. Herein, we developed a polydopamine (PDA)-based nanocarrier modified with Fe3O4 and Pt nanoparticles and loaded with necrostatin-1 (Nec-1) for the bimodal imaging and therapy of LN. Results demonstrate that Nec-1/PDA@Pt-Fe3O4 nanocarrier exhibits good biocompatibility. Nec-1, as an inhibitor of receptor-interacting protein 1 kinase, can be used to inhibit receptor-interacting protein 1 kinase activity and then reduces inflammation due to LN. Experiments in vitro and in the LN mouse model confirmed that the nanocarrier can reduce neutrophil extracellular traps (NETs) production by RIPK1 and alleviate the progression of inflammation. Previous studies proved that Pt nanoparticles can catalyze H2O2 to produce oxygen. A blood oxygen graph of mouse photoacoustic tomography confirmed that Nec-1/PDA@Pt-Fe3O4 can generate oxygen to fight against the hypoxic microenvironment of LN. PDA and Fe3O4 are used as photographic developers for photoacoustic or magnetic resonance imaging. The preliminary imaging results support Nec-1/PDA@Pt-Fe3O4 potential for photoacoustic/magnetic resonance dual-mode imaging, which can accurately and non-invasively monitor microscopic changes due to diseases. Nec-1/PDA@Pt-Fe3O4 combining these advantages exhibited outstanding performance in LN imaging and therapy. This work offers valuable insights into LN diagnosis and therapy.
- Open Access
- 25 July 2022
- Published by MDPI AG in Biosensors
- Vol. 12 (8) , 564
Portable Vertical Graphene@Au-Based Electrochemical Aptasensing Platform for Point-of-Care Testing of Tau Protein in the Blood
Alzheimer’s disease (AD) is a long-term neurodegenerative disease that poses a serious threat to human life and health. It is very important to develop a portable quantitative device for AD diagnosis and personal healthcare. Herein, we develop a portable electrochemical sensing platform for the point-of-care detection of AD biomarkers in the blood. Such a portable platform integrates nanoAu-modified vertical graphene (VG@Au) into a working electrode, which can significantly improve sensitivity and reduce detection limit due to the large specific surface, excellent electrical conductivity, high stability, and good biocompatibility. The tau protein, as an important factor in the course of AD, is selected as a key AD biomarker. The results show that the linear range of this sensing platform is 0.1 pg/mL to 1 ng/mL, with a detection limit of 0.034 pg/mL (S/N = 3), indicating that this portable sensing platform meets the demand for the detection of the tau protein in the blood. This work offers great potential for AD diagnosis and personal healthcare.
- 25 July 2022
- Published by MDPI AG in Biosensors
- Vol. 12 (8) , 564
Open AccessPortable Vertical Graphene@Au-Based Electrochemical Aptasensing Platform for Point-of-Care Testing of Tau Protein in the Blood
Alzheimer’s disease (AD) is a long-term neurodegenerative disease that poses a serious threat to human life and health. It is very important to develop a portable quantitative device for AD diagnosis and personal healthcare. Herein, we develop a portable electrochemical sensing platform for the point-of-care detection of AD biomarkers in the blood. Such a portable platform integrates nanoAu-modified vertical graphene (VG@Au) into a working electrode, which can significantly improve sensitivity and reduce detection limit due to the large specific surface, excellent electrical conductivity, high stability, and good biocompatibility. The tau protein, as an important factor in the course of AD, is selected as a key AD biomarker. The results show that the linear range of this sensing platform is 0.1 pg/mL to 1 ng/mL, with a detection limit of 0.034 pg/mL (S/N = 3), indicating that this portable sensing platform meets the demand for the detection of the tau protein in the blood. This work offers great potential for AD diagnosis and personal healthcare.