Ruimin Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Ruimin Li has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
- Xin Zhao
Nankai University
19 shared publications - Jinyu Qiu
Nankai University
18 shared publications - Qili Zhao
Nankai University
18 shared publications - Mingzhu Sun
National Key Laboratory of Intelligent Tracking and Forecasting for Infectious Diseases, Engineering Research Center of Trusted Behavior Intelligence, Ministry of Education, Tianjin Key Laboratory of Intelligent Robotics, Institute of Robotics and Automatic Information System, Nankai University, Tianjin 300350, China
10 shared publications - Minghui Li
Institute of Robotics and Automatic Information System (IRAIS), Tianjin Key Laboratory of Intelligent Robotics (tjKLIR), the Engineering Research Center of Trusted Behavior Intelligence, Ministry of Education, the Institute of Intelligence Technology and Robotic Systems, Shenzhen Research Institute of Nankai University, Shenzhen, China
9 shared publications - Shaojie Fu
Tianjin Key Laboratory of Intelligent Robotic (tjKLlR), Institute of Robotics and Automatic Information System (IRAIS), Nankai University, Tianjin, China
8 shared publications
Latest Publications
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 11  (11) , 12974-12981
Robotic Cell Contents Extraction in Biological Tissues Based on Cell Membrane Capacitance Variation
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 11  (11) , 12974-12981
Robotic Cell Contents Extraction in Biological Tissues Based on Cell Membrane Capacitance Variation
- 28 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. PP  (10834435) , 1-12
Robotic Fast Cell Positioning Based on a Narrow-Necked Micropipette in Cell Transportation
In this article, a narrow-necked micropipette (NNM) was designed, fabricated, and utilized for robotic fast cell positioning in cell transportation. First, key geometrical parameters of NNM were determined through the aspiration model and computational microfluidics model. Then, a heating-and-rotation method was developed to fabricate a narrow neck structure inside the micropipette based on a heating model. Further, the dynamic models of the cell before and after being held by the narrow neck were conducted. Based on that, a sliding mode motion controller and a deformation controller were designed for fast positioning of the cell at the narrow neck position and reducing the cell deformation, respectively. Robotic transportation results of 15 sheep oocytes demonstrate that our system can position the cell with a 100% success rate at doubled throughput in comparison to the traditional methods. The average positioning error and cell deformation degree are significantly reduced to 1.89 pixels and 2.59%, respectively. In addition, experiments on HeLa cells showed an average position time of 2.1 s with 100% success rate. Besides, limited harm to the cell survival rate is found through culturing experiments. With the above advantages, our robotic system is expected to improve cell transportation efficiency in the future.
- 28 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. PP  (10834435) , 1-12
Robotic Fast Cell Positioning Based on a Narrow-Necked Micropipette in Cell Transportation
In this article, a narrow-necked micropipette (NNM) was designed, fabricated, and utilized for robotic fast cell positioning in cell transportation. First, key geometrical parameters of NNM were determined through the aspiration model and computational microfluidics model. Then, a heating-and-rotation method was developed to fabricate a narrow neck structure inside the micropipette based on a heating model. Further, the dynamic models of the cell before and after being held by the narrow neck were conducted. Based on that, a sliding mode motion controller and a deformation controller were designed for fast positioning of the cell at the narrow neck position and reducing the cell deformation, respectively. Robotic transportation results of 15 sheep oocytes demonstrate that our system can position the cell with a 100% success rate at doubled throughput in comparison to the traditional methods. The average positioning error and cell deformation degree are significantly reduced to 1.89 pixels and 2.59%, respectively. In addition, experiments on HeLa cells showed an average position time of 2.1 s with 100% success rate. Besides, limited harm to the cell survival rate is found through culturing experiments. With the above advantages, our robotic system is expected to improve cell transportation efficiency in the future.
- 10 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Automation Science and Engineering
- Vol. 23  (15455955) , 1126-1137
Robotic Double Patch Clamp Based on Interactive Mechanical Modeling for Functional Connectivity Measurement Between Neurons
Double patch clamp technique, using two micropipette electrodes to patch and measure electrophysiological signals of two neurons, is essential for investigating the functional connections between neurons in brain. However, the interactive mechanical disturbances from the dual-micropipette motions inside viscoelastic brain tissue cause dynamic drifts of neurons, making double patching low efficiency and challenging. In this paper, an interactive mechanical modeling of two micropipettes approaching two cells in elastic environment was established to estimate the dynamic drift of the cells. Based on that, a synchronous descent strategy, an appropriate relative position of two cells, and an online trajectory plan of two micropipettes were determined to improve double patch clamp efficiency. Finally, a robotic double patch clamp operation process was established for functional connectivity measurement between neurons in brain slice. The effectiveness of the proposed work is validated through both finite element modeling and experiments. The double patch clamp experiments on neurons in visual cortex demonstrate that our method achieves a 40% improvement in success rate and a 38% improvement in speed in comparison to the traditional manual method. With the above advantages, diverse functional connectivity activities between neurons were found using our system, paving a solid ground for further research.
- 10 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Automation Science and Engineering
- Vol. 23  (15455955) , 1126-1137
Robotic Double Patch Clamp Based on Interactive Mechanical Modeling for Functional Connectivity Measurement Between Neurons
Double patch clamp technique, using two micropipette electrodes to patch and measure electrophysiological signals of two neurons, is essential for investigating the functional connections between neurons in brain. However, the interactive mechanical disturbances from the dual-micropipette motions inside viscoelastic brain tissue cause dynamic drifts of neurons, making double patching low efficiency and challenging. In this paper, an interactive mechanical modeling of two micropipettes approaching two cells in elastic environment was established to estimate the dynamic drift of the cells. Based on that, a synchronous descent strategy, an appropriate relative position of two cells, and an online trajectory plan of two micropipettes were determined to improve double patch clamp efficiency. Finally, a robotic double patch clamp operation process was established for functional connectivity measurement between neurons in brain slice. The effectiveness of the proposed work is validated through both finite element modeling and experiments. The double patch clamp experiments on neurons in visual cortex demonstrate that our method achieves a 40% improvement in success rate and a 38% improvement in speed in comparison to the traditional manual method. With the above advantages, diverse functional connectivity activities between neurons were found using our system, paving a solid ground for further research.
- 27 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74  (00189456) , 1-12
Robotic Precise Patch Clamp Measurement Method Based on a Tight and Stable Gigaseal
The patch clamp technique has been widely utilized to measure extremely weak ion channel signals. In patch clamp technique, the measurement accuracy and duration rely on the tightness and stability of the seal between the aspirated cell membrane and the recording micropipette. The current patch clamp operations utilize a pressure-driven seal formation method that can only provide a 2D driving force on a small part of the aspirated cell membrane, which easily causes looseness or even failures of the seal, significantly limiting the measurement quality of ion channel signals. Addressing this, a robotic precise patch clamp measurement method was proposed in this paper. In this method, a 3D-driven seal formation method is developed to improve the measurement accuracy and duration of ion channel signals by providing a tight and stable gigaohmscale seal (gigaseal). First, the forces applied by aspiration pressure and voltage on the aspirated cell membrane inside the micropipette are analyzed, respectively. Then, a dynamic model of the gigaseal formation process driven by pressure and voltage is established to provide a 3D driving force on the target aspirated cell membrane. Further, a dual-input adaptive sliding mode controller is developed to form a tight and stable gigaseal to improve the measurement accuracy and duration in patch clamp operation. Finally, a robotic precise patch clamp measurement process was established based on the above work. Experimental results on CA1 pyramidal neurons of mouse brain slices demonstrate that, in comparison to the current 2D-driven method, the proposed patch clamp measurement method has a 30% higher gigaseal formation success rate, 52% higher gigaseal resistance, and a fourfold increase in the success rate of 1-hour duration recordings, demonstrating the formation of a tighter and more stable gigaseal using our method. With the above advantages, a 3 dB-higher signal-to-noise ratio (SNR) was achieved, and long-term glycine-induced dynamic increases in amplitude and frequency of spontaneous excitatory postsynaptic currents (sEPSCs) were detected using the proposed method. With aforementioned higher measurement success rate, higher SNR and longer recording time, our patch clamp recording is expected to be applied in brain science and nervous system disease research in the future.
- 27 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74  (00189456) , 1-12
Robotic Precise Patch Clamp Measurement Method Based on a Tight and Stable Gigaseal
The patch clamp technique has been widely utilized to measure extremely weak ion channel signals. In patch clamp technique, the measurement accuracy and duration rely on the tightness and stability of the seal between the aspirated cell membrane and the recording micropipette. The current patch clamp operations utilize a pressure-driven seal formation method that can only provide a 2D driving force on a small part of the aspirated cell membrane, which easily causes looseness or even failures of the seal, significantly limiting the measurement quality of ion channel signals. Addressing this, a robotic precise patch clamp measurement method was proposed in this paper. In this method, a 3D-driven seal formation method is developed to improve the measurement accuracy and duration of ion channel signals by providing a tight and stable gigaohmscale seal (gigaseal). First, the forces applied by aspiration pressure and voltage on the aspirated cell membrane inside the micropipette are analyzed, respectively. Then, a dynamic model of the gigaseal formation process driven by pressure and voltage is established to provide a 3D driving force on the target aspirated cell membrane. Further, a dual-input adaptive sliding mode controller is developed to form a tight and stable gigaseal to improve the measurement accuracy and duration in patch clamp operation. Finally, a robotic precise patch clamp measurement process was established based on the above work. Experimental results on CA1 pyramidal neurons of mouse brain slices demonstrate that, in comparison to the current 2D-driven method, the proposed patch clamp measurement method has a 30% higher gigaseal formation success rate, 52% higher gigaseal resistance, and a fourfold increase in the success rate of 1-hour duration recordings, demonstrating the formation of a tighter and more stable gigaseal using our method. With the above advantages, a 3 dB-higher signal-to-noise ratio (SNR) was achieved, and long-term glycine-induced dynamic increases in amplitude and frequency of spontaneous excitatory postsynaptic currents (sEPSCs) were detected using the proposed method. With aforementioned higher measurement success rate, higher SNR and longer recording time, our patch clamp recording is expected to be applied in brain science and nervous system disease research in the future.
- Open Access
Precise Control of Micropipette Flow Rate for Fluorescence Imaging in In Vivo Micromanipulation
Precise regulation of micropipette outlet flow is critical for fluorescence imaging in vivo micromanipulations. In such procedures, a micropipette with a micro-sized opening is driven by gas pressure to deliver internal solution into the in vivo environment. The outlet flow rate needs to be precisely regulated to ensure a uniform and stable fluorescence distribution. However, conventional manual pressure injection methods face inherent limitations, including insufficient precision and poor reproducibility. Existing commercial microinjection systems lack a quantitative relationship between pressure and flow rate. And existing calibration methods in the field of microfluidics suffer from a limited flow-rate measurement resolution, constraining the establishment of a precise pressure–flow quantitative relationship. To address these challenges, we developed a closed-loop pressure regulation system with 1 Pa-level control resolution and established a quantitative calibration of the pressure–flow relationship using a droplet-based method. The calibration revealed a linear relationship with a mean pressure–flow gain of 4.846 (R2 > 0.99). Validation results demonstrated that the system achieved the target outlet flow rate with a flow control error less than 10 fL/s. Finally, the application results in brain-slice environment confirmed its capability to maintain stable fluorescence imaging, with fluorescence intensity fluctuations around 1.3%. These results demonstrated that the proposed approach provides stable, precise, and reproducible flow regulation under physiologically relevant conditions, thereby offering a valuable tool for in vivo micromanipulation and detection.Open AccessPrecise Control of Micropipette Flow Rate for Fluorescence Imaging in In Vivo Micromanipulation
Precise regulation of micropipette outlet flow is critical for fluorescence imaging in vivo micromanipulations. In such procedures, a micropipette with a micro-sized opening is driven by gas pressure to deliver internal solution into the in vivo environment. The outlet flow rate needs to be precisely regulated to ensure a uniform and stable fluorescence distribution. However, conventional manual pressure injection methods face inherent limitations, including insufficient precision and poor reproducibility. Existing commercial microinjection systems lack a quantitative relationship between pressure and flow rate. And existing calibration methods in the field of microfluidics suffer from a limited flow-rate measurement resolution, constraining the establishment of a precise pressure–flow quantitative relationship. To address these challenges, we developed a closed-loop pressure regulation system with 1 Pa-level control resolution and established a quantitative calibration of the pressure–flow relationship using a droplet-based method. The calibration revealed a linear relationship with a mean pressure–flow gain of 4.846 (R2 > 0.99). Validation results demonstrated that the system achieved the target outlet flow rate with a flow control error less than 10 fL/s. Finally, the application results in brain-slice environment confirmed its capability to maintain stable fluorescence imaging, with fluorescence intensity fluctuations around 1.3%. These results demonstrated that the proposed approach provides stable, precise, and reproducible flow regulation under physiologically relevant conditions, thereby offering a valuable tool for in vivo micromanipulation and detection. - 11 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 31  (1) , 512-522
Robotic Micropuncture With Preload Strategy for Retinal Vein Cannulation
Retinal vein cannulation (RVC) is a surgical procedure utilized in the treatment of retinal vein occlusion. During RVC, the micropuncture process encounters challenges due to unstable contact between the bent needle and the retinal vein, potentially resulting in micropuncture failure. To enhance the success rate, a robotic micropuncture procedure with preload strategy is proposed, which can increase the tissue stiffness and improve stability. First, a nonlinear viscoelastic (NV) model is developed to characterize the nonlinearity and relaxation behavior of the preload force. Subsequently, an NV model based adaptive integral terminal sliding mode controller (NAITSMC) is designed to ensure precise force tracking under tissue uncertainty and respiratory motion. The effectiveness of the robotic micropuncture is validated through in vitro experiments conducted on open-sky porcine eyes. The experimental results indicate that the NV model is more suitable for modeling the force applied to the retinal vein under various inner pressure cases. Under simulated respiratory motion, the NAITSMC demonstrates statistically reduction in error compared to the advanced sliding mode force controller. The preload strategy significantly improves the success rate, achieving a maximum rate of 90%. Furthermore, a preload force of 40 μN is recommended, demonstrating a higher success rate while maintaining acceptable safety considerations.
- 11 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 31  (1) , 512-522
Robotic Micropuncture With Preload Strategy for Retinal Vein Cannulation
Retinal vein cannulation (RVC) is a surgical procedure utilized in the treatment of retinal vein occlusion. During RVC, the micropuncture process encounters challenges due to unstable contact between the bent needle and the retinal vein, potentially resulting in micropuncture failure. To enhance the success rate, a robotic micropuncture procedure with preload strategy is proposed, which can increase the tissue stiffness and improve stability. First, a nonlinear viscoelastic (NV) model is developed to characterize the nonlinearity and relaxation behavior of the preload force. Subsequently, an NV model based adaptive integral terminal sliding mode controller (NAITSMC) is designed to ensure precise force tracking under tissue uncertainty and respiratory motion. The effectiveness of the robotic micropuncture is validated through in vitro experiments conducted on open-sky porcine eyes. The experimental results indicate that the NV model is more suitable for modeling the force applied to the retinal vein under various inner pressure cases. Under simulated respiratory motion, the NAITSMC demonstrates statistically reduction in error compared to the advanced sliding mode force controller. The preload strategy significantly improves the success rate, achieving a maximum rate of 90%. Furthermore, a preload force of 40 μN is recommended, demonstrating a higher success rate while maintaining acceptable safety considerations.
- 2 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74  (00189456) , 1-8
Robotic Improved Micropipette Aspiration Method for Accurate Measurement of Cellular Mechanical Properties
For the first time, an improved robotic micropipette aspiration (MA) method considering the effects of the intra-cellular pressure, friction between cell and micropipette, and the micropipette opening size was proposed for improving the measurement accuracy of the cell elasticity properties in this paper. First, an elastic energy model of the aspirated cell was established to analyze the effects of intracellular pressure on MA results. Then a force analysis of MA process was conducted to evaluate the influences of the friction force between the cell surface and micropipette opening as well as the inner diameter of the micropipette opening to MA results. Based on the above work, an improved robotic MA process was developed for reducing the cell elasticity measurement errors through automated release of intracellular pressure, micropipette opening polishing and inner diameter control of the micropipette. The effectiveness of the above work was validated by both finite elemental model (FEM) and MA experiments. The MA results on porcine oocytes demonstrate that our proposed MA method can rectify the 20.11%, 35.08% and 6.80% measure errors of cell Young’s modulus caused by the above three factors, respectively. Our research may provide a more objective evaluation of cell mechanical properties in the related research.
- 2 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74  (00189456) , 1-8
Robotic Improved Micropipette Aspiration Method for Accurate Measurement of Cellular Mechanical Properties
For the first time, an improved robotic micropipette aspiration (MA) method considering the effects of the intra-cellular pressure, friction between cell and micropipette, and the micropipette opening size was proposed for improving the measurement accuracy of the cell elasticity properties in this paper. First, an elastic energy model of the aspirated cell was established to analyze the effects of intracellular pressure on MA results. Then a force analysis of MA process was conducted to evaluate the influences of the friction force between the cell surface and micropipette opening as well as the inner diameter of the micropipette opening to MA results. Based on the above work, an improved robotic MA process was developed for reducing the cell elasticity measurement errors through automated release of intracellular pressure, micropipette opening polishing and inner diameter control of the micropipette. The effectiveness of the above work was validated by both finite elemental model (FEM) and MA experiments. The MA results on porcine oocytes demonstrate that our proposed MA method can rectify the 20.11%, 35.08% and 6.80% measure errors of cell Young’s modulus caused by the above three factors, respectively. Our research may provide a more objective evaluation of cell mechanical properties in the related research.
- 1 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Automation Science and Engineering
- Vol. 22  (15455955) , 13716-13727
Robotic Fluorescent Lighting Method Based on Dynamic Fluorescence Imaging Modeling for In Vivo Cell Manipulation
In vivo cell manipulation is crucial for understanding organ functions and dysfunctions at the cellular level. Due to its low optical transparency, the in vivo environment needs to be lighted up first to visualize the targets for manipulation. At present, operators usually carefully blow a micropipette filled with fluorescent dye solution to create a fluorescence field around the micropipette opening, lighting up the in vivo environment. This manual dynamic control of the fluorescence field is usually a low-accuracy, labor-intensive, and high-skill requirement task, becoming even more challenging when the micropipette moves to locate or approach target cells. A large number of in vivo lighting-control tests may improve manual control efficiency of the fluorescent field, but they usually cost many precise animal samples, making them costly and often unaffordable. To enhance the dynamic control efficiency of the fluorescent field while reducing experimental costs, a robotic fluorescent lighting control method is proposed based on an in vivo dynamic fluorescent imaging simulator. First, a dynamic fluorescence imaging model composing an injection model, a diffusion model, and a luminescence model of fluorescent molecules is established to simulate the fluorescence field in vivo. The fluorescent intensity distribution obtained through the model is highly in accordance with experimental results. Based on this model, an adaptive sliding mode controller is employed to achieve the desired fluorescent intensity in the brain tissue. Both the simulation results and the experimental results demonstrate significant advantages of the proposed controller in terms of control accuracy and stability compared to the traditional PID controller and manual operation. the fluorescent intensity at a specified position in the fluorescent field. Simulations based on the established model, along with experiments on brain tissues, demonstrate the controller’s effectiveness. Our system is expected to reduce human involvement and enable high-precision lighting for in vivo cell manipulation in the future.
- 1 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Automation Science and Engineering
- Vol. 22  (15455955) , 13716-13727
Robotic Fluorescent Lighting Method Based on Dynamic Fluorescence Imaging Modeling for In Vivo Cell Manipulation
In vivo cell manipulation is crucial for understanding organ functions and dysfunctions at the cellular level. Due to its low optical transparency, the in vivo environment needs to be lighted up first to visualize the targets for manipulation. At present, operators usually carefully blow a micropipette filled with fluorescent dye solution to create a fluorescence field around the micropipette opening, lighting up the in vivo environment. This manual dynamic control of the fluorescence field is usually a low-accuracy, labor-intensive, and high-skill requirement task, becoming even more challenging when the micropipette moves to locate or approach target cells. A large number of in vivo lighting-control tests may improve manual control efficiency of the fluorescent field, but they usually cost many precise animal samples, making them costly and often unaffordable. To enhance the dynamic control efficiency of the fluorescent field while reducing experimental costs, a robotic fluorescent lighting control method is proposed based on an in vivo dynamic fluorescent imaging simulator. First, a dynamic fluorescence imaging model composing an injection model, a diffusion model, and a luminescence model of fluorescent molecules is established to simulate the fluorescence field in vivo. The fluorescent intensity distribution obtained through the model is highly in accordance with experimental results. Based on this model, an adaptive sliding mode controller is employed to achieve the desired fluorescent intensity in the brain tissue. Both the simulation results and the experimental results demonstrate significant advantages of the proposed controller in terms of control accuracy and stability compared to the traditional PID controller and manual operation. the fluorescent intensity at a specified position in the fluorescent field. Simulations based on the established model, along with experiments on brain tissues, demonstrate the controller’s effectiveness. Our system is expected to reduce human involvement and enable high-precision lighting for in vivo cell manipulation in the future.
- Open Access
Robotic Fast Patch Clamp in Brain Slices Based on Stepwise Micropipette Navigation and Gigaseal Formation Control
The patch clamp technique has become the gold standard for neuron electrophysiology research in brain science. Brain slices have been widely utilized as the targets of the patch clamp technique due to their higher optical transparency compared to a live brain and their intercellular connectivity in comparison to cultured single neurons. However, the narrow working space, small scope, and depth of the field of view make the positioning of the operation’s micropipette to the target neuron a time-consuming task reliant on a high level of experience, significantly slowing down operation of the patch clamp technique in brain slices. Further, the current poor controllability in gigaseal formation, which is the key to electrophysiology signal recording, significantly lowers the patch clamp success rate. In this paper, a stepwise navigation of the micropipette is conducted to accelerate the positioning process of the micropipette tip to the target neuron in the brain slice. Then, a fuzzy proportional–integral–derivative controller is designed to control the gigaseal formation process along a designed resistance curve. The experimental results demonstrate an almost doubled patch clamp technique speed, with a 25% improvement in the success rate compared to the conventional manual method. The above advantages may promote the application of our method in brain science research based on brain slice platforms.
Open AccessRobotic Fast Patch Clamp in Brain Slices Based on Stepwise Micropipette Navigation and Gigaseal Formation Control
The patch clamp technique has become the gold standard for neuron electrophysiology research in brain science. Brain slices have been widely utilized as the targets of the patch clamp technique due to their higher optical transparency compared to a live brain and their intercellular connectivity in comparison to cultured single neurons. However, the narrow working space, small scope, and depth of the field of view make the positioning of the operation’s micropipette to the target neuron a time-consuming task reliant on a high level of experience, significantly slowing down operation of the patch clamp technique in brain slices. Further, the current poor controllability in gigaseal formation, which is the key to electrophysiology signal recording, significantly lowers the patch clamp success rate. In this paper, a stepwise navigation of the micropipette is conducted to accelerate the positioning process of the micropipette tip to the target neuron in the brain slice. Then, a fuzzy proportional–integral–derivative controller is designed to control the gigaseal formation process along a designed resistance curve. The experimental results demonstrate an almost doubled patch clamp technique speed, with a 25% improvement in the success rate compared to the conventional manual method. The above advantages may promote the application of our method in brain science research based on brain slice platforms.