Hong Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hong Wang has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Peter Bradley Shull
State Key Laboratory of Mechanical System and Vibration, School of Mechanical Engineering, Shanghai Jiao Tong University, Shanghai, China
6 shared publications - Chenquan Xu
State Key Laboratory of Mechanical System and Vibration, School of Mechanical Engineering, Shanghai Jiao Tong University, Shanghai, China
3 shared publications Eran Gazit
Center for the Study of Movement, Cognition and Mobility, Neurological Institute Tel Aviv Sourasky Medical Center Tel Aviv Israel
3 shared publications- Kezhe Zhu
State Key Laboratory of Mechanical System and Vibration, School of Mechanical Engineering, Shanghai Jiao Tong University, Shanghai, China
3 shared publications Marina Brozgol
Center for the Study of Movement, Cognition and Mobility, Neurological Institute Tel Aviv Sourasky Medical Center Tel Aviv Israel
3 shared publicationsPenina Ponger
Department of Neurology Tel Aviv Sourasky Medical Center Tel Aviv Israel
3 shared publications
Latest Publications
- Open Access
- 10 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 34 (15344320) , 1518-1527
Single-Camera Knee Adduction Moment Estimation for Individuals With Knee Osteoarthritis via a Novel Spatio-Temporal Graph Transformer Network
Accurately estimating knee adduction moment (KAM) is essential for understanding knee biomechanics and may aid in mitigating medial knee osteoarthritis (OA) progression. However, traditional motion capture and force plate systems are costly and restricted to lab-oratories. Multi-wearable sensor and multi-camera setups have been explored but remain complex and lack validation across diverse gait modifications in individuals with knee OA. This study proposes a novel Spatio-Temporal Graph Transformer Network (STGTN) for estimating KAM using a single-camera setup. Fourteen individuals with medial compartment knee OA performed gait modifications, including variations in walking speed, foot progression angle, step width, trunk sway, and dual-task walking. The proposed model achieved a KAM root mean square error of 0.48% BW·BH and a peak KAM mean absolute error of 0.43% BW·BH, both within clinically meaningful error thresholds (0.5–2.1% BW·BH). Additionally, the model demonstrated sensitivity to gait modifications, identifying significant reductions in peak KAM during slow walking, toe-in gait, wide step width, and increased trunk sway conditions (p<0.05). These findings suggest that single-camera-based KAM estimation could be a feasible approach for real-world gait assessment, with potential applications in clinical and rehabilitation settings for monitoring knee join.
- 10 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 34 (15344320) , 1518-1527
Open AccessSingle-Camera Knee Adduction Moment Estimation for Individuals With Knee Osteoarthritis via a Novel Spatio-Temporal Graph Transformer Network
Accurately estimating knee adduction moment (KAM) is essential for understanding knee biomechanics and may aid in mitigating medial knee osteoarthritis (OA) progression. However, traditional motion capture and force plate systems are costly and restricted to lab-oratories. Multi-wearable sensor and multi-camera setups have been explored but remain complex and lack validation across diverse gait modifications in individuals with knee OA. This study proposes a novel Spatio-Temporal Graph Transformer Network (STGTN) for estimating KAM using a single-camera setup. Fourteen individuals with medial compartment knee OA performed gait modifications, including variations in walking speed, foot progression angle, step width, trunk sway, and dual-task walking. The proposed model achieved a KAM root mean square error of 0.48% BW·BH and a peak KAM mean absolute error of 0.43% BW·BH, both within clinically meaningful error thresholds (0.5–2.1% BW·BH). Additionally, the model demonstrated sensitivity to gait modifications, identifying significant reductions in peak KAM during slow walking, toe-in gait, wide step width, and increased trunk sway conditions (p<0.05). These findings suggest that single-camera-based KAM estimation could be a feasible approach for real-world gait assessment, with potential applications in clinical and rehabilitation settings for monitoring knee join.
- Open Access
- 12 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 34 (15344320) , 650-662
Real-Time OpenSim via IMUs for Full Body Kinematics During Gait, Sports, Exercise, and Dance Movements
Despite the growing demand for healthcare services due to an aging population, patients often avoid traditional rehabilitation centers due to high costs, time constraints, and discomfort experienced in laboratory or hospital settings. Home-based rehabilitation offers a promising alternative, but real-time kinematic monitoring and assessment remain challenging. We thus propose a real-time, wireless, portable approach for computing full-body kinematics through OpenSim. Twenty-two subjects performed walking, running, squatting, boxing, yoga, dance, badminton, stair climbing, and seated extremity exercise movements, while wearing 12 SageMotion inertial measurement units (IMUs). Real-time IMU kinematics were computed at 20 Hz and offline kinematics at 100 Hz and were compared with reference optical motion capture kinematics to determine accuracy. Real-time walking and stair climbing were most accurate, both with median RMSE of 5.3 deg. The most accurate joint angle was lumber rotation with median RMSE of 2.7 deg, and the overall median RMSE for all activities across all joints was 7.4 deg. Overall mean RMSE between real-time and offline IMU estimation was 0.7 deg, and mean latency from IMU data reception at the processing hub to kinematics generation was 31.7 ms. This approach could dramatically improve clinical and remote care by enabling rapid assessment and real-time biofeedback for rehabilitation, with potential to significantly enhance patient assessment and treatment outcomes.
- 12 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 34 (15344320) , 650-662
Open AccessReal-Time OpenSim via IMUs for Full Body Kinematics During Gait, Sports, Exercise, and Dance Movements
Despite the growing demand for healthcare services due to an aging population, patients often avoid traditional rehabilitation centers due to high costs, time constraints, and discomfort experienced in laboratory or hospital settings. Home-based rehabilitation offers a promising alternative, but real-time kinematic monitoring and assessment remain challenging. We thus propose a real-time, wireless, portable approach for computing full-body kinematics through OpenSim. Twenty-two subjects performed walking, running, squatting, boxing, yoga, dance, badminton, stair climbing, and seated extremity exercise movements, while wearing 12 SageMotion inertial measurement units (IMUs). Real-time IMU kinematics were computed at 20 Hz and offline kinematics at 100 Hz and were compared with reference optical motion capture kinematics to determine accuracy. Real-time walking and stair climbing were most accurate, both with median RMSE of 5.3 deg. The most accurate joint angle was lumber rotation with median RMSE of 2.7 deg, and the overall median RMSE for all activities across all joints was 7.4 deg. Overall mean RMSE between real-time and offline IMU estimation was 0.7 deg, and mean latency from IMU data reception at the processing hub to kinematics generation was 31.7 ms. This approach could dramatically improve clinical and remote care by enabling rapid assessment and real-time biofeedback for rehabilitation, with potential to significantly enhance patient assessment and treatment outcomes.
- Open Access
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 34, 3164-3177
Pathology-Informed Augmentation Improves Cross-Cohort IMU-to-vGRF Estimation Between Healthy Adults and Adults With Osteoarthritis
Estimating vertical ground reaction forces (vGRF) from wearable inertial measurement units (IMUs) degrades when models are applied across populations with different gait characteristics. We evaluated pathology-informed augmentation to improve generalization between healthy adults and adults with lower-limb osteoarthritis. We collected instrumented-treadmill walking data from 47 adults, including 29 healthy participants and 18 with radiographic osteoarthritis, predominantly knee osteoarthritis. Force-plate vGRFs were synchronized with body-worn IMUs. We developed a Transformer-based IMU model with low-rank multi-stream fusion (LMF), which learns compact shared patterns linking accelerometer and gyroscope signals across segments. We then applied a novel ratio-based augmentation that transforms source-cohort strides into target-like strides using donor-derived gait-feature ratios for stance duration, peak vGRF magnitude, dominant acceleration frequency, and segment-level acceleration amplitude. Generalization was tested in two directions, healthy-to-osteoarthritis (H2K) and osteoarthritis-to-healthy (K2H), using participant-disjoint splits. Augmentation reduced source-target separation in a low-dimensional gait feature space by 87% in H2K and 88% in K2H. On held-out participants, mass-normalized root-mean-square error (RMSE, N/kg) decreased by 10.5% in H2K and 11.4% in K2H. Expanded training without augmentation yielded smaller changes, with 4.9% in H2K and 0.2% in K2H.Peak accuracy was high: 96.7% of matched peaks in H2K and 97.0% in K2H were within 10% of the reference peak height. An interpretable, ratio-based augmentation that targets temporal, kinetic, spectral, and segment-amplitude features improves cross-cohort generalization of IMU-to-vGRF models and may reduce reliance on large target cohort datasets.
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 34, 3164-3177
Open AccessPathology-Informed Augmentation Improves Cross-Cohort IMU-to-vGRF Estimation Between Healthy Adults and Adults With Osteoarthritis
Estimating vertical ground reaction forces (vGRF) from wearable inertial measurement units (IMUs) degrades when models are applied across populations with different gait characteristics. We evaluated pathology-informed augmentation to improve generalization between healthy adults and adults with lower-limb osteoarthritis. We collected instrumented-treadmill walking data from 47 adults, including 29 healthy participants and 18 with radiographic osteoarthritis, predominantly knee osteoarthritis. Force-plate vGRFs were synchronized with body-worn IMUs. We developed a Transformer-based IMU model with low-rank multi-stream fusion (LMF), which learns compact shared patterns linking accelerometer and gyroscope signals across segments. We then applied a novel ratio-based augmentation that transforms source-cohort strides into target-like strides using donor-derived gait-feature ratios for stance duration, peak vGRF magnitude, dominant acceleration frequency, and segment-level acceleration amplitude. Generalization was tested in two directions, healthy-to-osteoarthritis (H2K) and osteoarthritis-to-healthy (K2H), using participant-disjoint splits. Augmentation reduced source-target separation in a low-dimensional gait feature space by 87% in H2K and 88% in K2H. On held-out participants, mass-normalized root-mean-square error (RMSE, N/kg) decreased by 10.5% in H2K and 11.4% in K2H. Expanded training without augmentation yielded smaller changes, with 4.9% in H2K and 0.2% in K2H.Peak accuracy was high: 96.7% of matched peaks in H2K and 97.0% in K2H were within 10% of the reference peak height. An interpretable, ratio-based augmentation that targets temporal, kinetic, spectral, and segment-amplitude features improves cross-cohort generalization of IMU-to-vGRF models and may reduce reliance on large target cohort datasets.
- 13 January 2025
- Published by Wiley in Movement Disorders
- Vol. 40 (4) , 745-751
Step Width Haptic Feedback for Gait Stability in Spinocerebellar Ataxia: Preliminary Results
Background: Wider step width and lower step‐to‐step variability are linked to improved gait stability and reduced fall risk. It is unclear if patients with spinocerebellar ataxia (SCA) can learn to adjust these aspects of gait to reduce fall risk.Objectives: The aims were to examine the possibility of using wearable step width haptic biofeedback to enhance gait stability and reduce fall risk in individuals with SCA.Methods: Thirteen people with SCA type 3 performed step width training (single session) using real‐time feedback.Results: Step width increased post‐training (19.3 cm, interquartile range [IQR] 16.3–20.2 cm) and at retention (16.6 cm, IQR 16.2–21.1 cm), compared to baseline (11.0 cm, IQR 5.2–15.2 cm; P < 0.001). Step width variability decreased during post‐training (19.7%, IQR 17.4%–26.2%) and at retention (22.3%, IQR 18.6%–30.2%), compared to baseline (44.5%, IQR 28.5%–71.2%; P < 0.001). Crossover steps, another mark of instability, decreased after training (P < 0.031).Conclusions: These pilot results suggest that patients with SCA can use a novel, wearable biofeedback system to improve their gait stability. © 2025 International Parkinson and Movement Disorder Society.
- 13 January 2025
- Published by Wiley in Movement Disorders
- Vol. 40 (4) , 745-751
Step Width Haptic Feedback for Gait Stability in Spinocerebellar Ataxia: Preliminary Results
Background: Wider step width and lower step‐to‐step variability are linked to improved gait stability and reduced fall risk. It is unclear if patients with spinocerebellar ataxia (SCA) can learn to adjust these aspects of gait to reduce fall risk.Objectives: The aims were to examine the possibility of using wearable step width haptic biofeedback to enhance gait stability and reduce fall risk in individuals with SCA.Methods: Thirteen people with SCA type 3 performed step width training (single session) using real‐time feedback.Results: Step width increased post‐training (19.3 cm, interquartile range [IQR] 16.3–20.2 cm) and at retention (16.6 cm, IQR 16.2–21.1 cm), compared to baseline (11.0 cm, IQR 5.2–15.2 cm; P < 0.001). Step width variability decreased during post‐training (19.7%, IQR 17.4%–26.2%) and at retention (22.3%, IQR 18.6%–30.2%), compared to baseline (44.5%, IQR 28.5%–71.2%; P < 0.001). Crossover steps, another mark of instability, decreased after training (P < 0.031).Conclusions: These pilot results suggest that patients with SCA can use a novel, wearable biofeedback system to improve their gait stability. © 2025 International Parkinson and Movement Disorder Society.
- 27 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 29 (1) , 81-94
Step Width Estimation in Individuals With and Without Neurodegenerative Disease via a Novel Data-Augmentation Deep Learning Model and Minimal Wearable Inertial Sensors
Step width is vital for gait stability, postural balance control, and fall risk reduction. However, estimating step width typically requires either fixed cameras or a full kinematic body suit of wearable inertial measurement units (IMUs), both of which are often too expensive and time-consuming for clinical application. We thus propose a novel data-augmented deep learning model for estimating step width in individuals with and without neurodegenerative disease using a minimal set of wearable IMUs. Twelve patients with neurodegenerative, clinically diagnosed Spinocerebellar ataxia type 3 (SCA3) performed over ground walking trials, and seventeen healthy individuals performed treadmill walking trials at various speeds and gait modifications while wearing IMUs on each shank and the pelvis. Results demonstrated step width mean absolute errors of 3.3 $\pm$ 0.7cm and 2.9 $\pm$ 0.5cm for the neurodegenerative and healthy groups, respectively, which were below the minimal clinically important difference of 6.0cm. Step width variability mean absolute errors were 1.5cm and 0.8cm for neurodegenerative and healthy groups, respectively. Data augmentation significantly improved accuracy performance in the neurodegenerative group, likely because they exhibited larger variations in walking kinematics as compared with healthy subjects. These results could enable clinically meaningful and accurate portable step width monitoring for individuals with and without neurodegenerative disease, potentially enhancing rehabilitative training, assessment, and dynamic balance control in clinical and real-life settings.
- 27 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 29 (1) , 81-94
Step Width Estimation in Individuals With and Without Neurodegenerative Disease via a Novel Data-Augmentation Deep Learning Model and Minimal Wearable Inertial Sensors
Step width is vital for gait stability, postural balance control, and fall risk reduction. However, estimating step width typically requires either fixed cameras or a full kinematic body suit of wearable inertial measurement units (IMUs), both of which are often too expensive and time-consuming for clinical application. We thus propose a novel data-augmented deep learning model for estimating step width in individuals with and without neurodegenerative disease using a minimal set of wearable IMUs. Twelve patients with neurodegenerative, clinically diagnosed Spinocerebellar ataxia type 3 (SCA3) performed over ground walking trials, and seventeen healthy individuals performed treadmill walking trials at various speeds and gait modifications while wearing IMUs on each shank and the pelvis. Results demonstrated step width mean absolute errors of 3.3 $\pm$ 0.7cm and 2.9 $\pm$ 0.5cm for the neurodegenerative and healthy groups, respectively, which were below the minimal clinically important difference of 6.0cm. Step width variability mean absolute errors were 1.5cm and 0.8cm for neurodegenerative and healthy groups, respectively. Data augmentation significantly improved accuracy performance in the neurodegenerative group, likely because they exhibited larger variations in walking kinematics as compared with healthy subjects. These results could enable clinically meaningful and accurate portable step width monitoring for individuals with and without neurodegenerative disease, potentially enhancing rehabilitative training, assessment, and dynamic balance control in clinical and real-life settings.
- Open Access
- 9 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in TechRxiv
Step Width Estimation in Individuals with and without Neurodegenerative Disease via a Novel Data-Augmentation Deep Learning Model and Minimal Wearable Inertial Sensors
Step width is vital for gait stability, postural balance control, and fall risk reduction. However, estimating step width typically requires either grounded cameras or a full kinematic body suit of wearable inertial measurement units (IMUs), both of which are often too expensive and time-consuming for clinical application. We thus propose a novel data-augmented deep learning model for estimating step width in individuals with and without neurodegenerative disease using a minimal set of wearable IMUs. Twelve patients with neurodegenerative, clinically diagnosed Spinocerebellar ataxia type 3 (SCA3) performed over ground walking trials, and seventeen healthy individuals performed treadmill walking trials at various speeds and gait modifications while wearing IMUs on each shank and the pelvis. Results demonstrated step width mean absolute errors of 3.3±0.7cm and 2.9±0.5cm for the neurodegenerative and healthy groups, respectively, which were below the minimal clinically important difference of 6.0cm. Step width variability mean absolute errors were 1.5cm and 0.8cm for neurodegenerative and healthy groups, respectively. Data augmentation significantly improved accuracy performance in the neurodegenerative group, likely because they exhibited larger variations in walking kinematics as compared with healthy subjects. These results could enable clinically meaningful and accurate portable step width monitoring for individuals with and without neurodegenerative disease, potentially enhancing rehabilitative training, assessment, and dynamic balance control in clinical and real-life settings.
- 9 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in TechRxiv
Open AccessStep Width Estimation in Individuals with and without Neurodegenerative Disease via a Novel Data-Augmentation Deep Learning Model and Minimal Wearable Inertial Sensors
Step width is vital for gait stability, postural balance control, and fall risk reduction. However, estimating step width typically requires either grounded cameras or a full kinematic body suit of wearable inertial measurement units (IMUs), both of which are often too expensive and time-consuming for clinical application. We thus propose a novel data-augmented deep learning model for estimating step width in individuals with and without neurodegenerative disease using a minimal set of wearable IMUs. Twelve patients with neurodegenerative, clinically diagnosed Spinocerebellar ataxia type 3 (SCA3) performed over ground walking trials, and seventeen healthy individuals performed treadmill walking trials at various speeds and gait modifications while wearing IMUs on each shank and the pelvis. Results demonstrated step width mean absolute errors of 3.3±0.7cm and 2.9±0.5cm for the neurodegenerative and healthy groups, respectively, which were below the minimal clinically important difference of 6.0cm. Step width variability mean absolute errors were 1.5cm and 0.8cm for neurodegenerative and healthy groups, respectively. Data augmentation significantly improved accuracy performance in the neurodegenerative group, likely because they exhibited larger variations in walking kinematics as compared with healthy subjects. These results could enable clinically meaningful and accurate portable step width monitoring for individuals with and without neurodegenerative disease, potentially enhancing rehabilitative training, assessment, and dynamic balance control in clinical and real-life settings.
- 26 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 26 (10) , 5097-5108
A Novel PPG-FMG-ACC Wristband for Hand Gesture Recognition
Wrist-based hand gesture recognition has the potential to unlock naturalistic human-computer interaction for a vast array of virtual and augmented reality applications. Photoplethysmography (PPG), force myography (FMG), and accelerometry (ACC) have generally been proposed as isolated single sensing modalities for gesture recognition, but any of these alone is inherently limited in the amount of biological information it can collect during finger and hand movements. We thus propose a novel, wrist-based, PPG-FMG-ACC combined sensing approach based on a multi-head attention mechanism fusion convolutional neural network (CNN-AF) for gesture recognition. Nine subjects performed twelve hand gestures involving various wrist and finger postures. Experimental results showed that multi-modal fusion improved classification performance significantly ( $p$ $< $ 0.01) compared to any single sensing modality, and the F1-score of the combined PPG-FMG-ACC approach was 40.1% higher than PPG alone, 27.4% higher than ACC alone, and 11.9% higher than FMG alone. To the best of our knowledge, this paper is the first to combine wrist-based PPG, FMG, and ACC signals for hand gesture recognition. These results could serve to inform wrist-based gesture recognition design (e.g., via a smartwatch) and thus expand the capabilities of intuitive and ubiquitous human-machine interaction.
- 26 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 26 (10) , 5097-5108
A Novel PPG-FMG-ACC Wristband for Hand Gesture Recognition
Wrist-based hand gesture recognition has the potential to unlock naturalistic human-computer interaction for a vast array of virtual and augmented reality applications. Photoplethysmography (PPG), force myography (FMG), and accelerometry (ACC) have generally been proposed as isolated single sensing modalities for gesture recognition, but any of these alone is inherently limited in the amount of biological information it can collect during finger and hand movements. We thus propose a novel, wrist-based, PPG-FMG-ACC combined sensing approach based on a multi-head attention mechanism fusion convolutional neural network (CNN-AF) for gesture recognition. Nine subjects performed twelve hand gestures involving various wrist and finger postures. Experimental results showed that multi-modal fusion improved classification performance significantly ( $p$ $< $ 0.01) compared to any single sensing modality, and the F1-score of the combined PPG-FMG-ACC approach was 40.1% higher than PPG alone, 27.4% higher than ACC alone, and 11.9% higher than FMG alone. To the best of our knowledge, this paper is the first to combine wrist-based PPG, FMG, and ACC signals for hand gesture recognition. These results could serve to inform wrist-based gesture recognition design (e.g., via a smartwatch) and thus expand the capabilities of intuitive and ubiquitous human-machine interaction.
- Open Access
- 3 March 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 30 (15344320) , 621-631
Activities of Daily Living-Based Rehabilitation System for Arm and Hand Motor Function Retraining After Stroke
Most stroke survivors have difficulties completing activities of daily living (ADLs) independently. However, few rehabilitation systems have focused on ADLs-related training for gross and fine motor function together. We propose an ADLs-based serious game rehabilitation system for the training of motor function and coordination of both arm and hand movement where the user performs corresponding ADLs movements to interact with the target in the serious game. A multi-sensor fusion model based on electromyographic (EMG), force myographic (FMG), and inertial sensing was developed to estimate users’ natural upper limb movement. Eight healthy subjects and three stroke patients were recruited in an experiment to validate the system’s effectiveness. The performance of different sensor and classifier configurations on hand gesture classification against the arm position variations were analyzed, and qualitative patient questionnaires were conducted. Results showed that elbow extension/flexion has a more significant negative influence on EMG-based, FMG-based, and EMG+FMG-based hand gesture recognition than shoulder abduction/adduction does. In addition, there was no significant difference in the negative influence of shoulder abduction/adduction and shoulder flexion/extension on hand gesture recognition. However, there was a significant interaction between sensor configurations and algorithm configurations in both offline and real-time recognition accuracy. The EMG+FMG-combined multi-position classifier model had the best performance against arm position change. In addition, all the stroke patients reported their ADLs-related ability could be restored by using the system. These results demonstrate that the multi-sensor fusion model could estimate hand gestures and gross movement accurately, and the proposed training system has the potential to improve patients’ ability to perform ADLs.
- 3 March 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 30 (15344320) , 621-631
Open AccessActivities of Daily Living-Based Rehabilitation System for Arm and Hand Motor Function Retraining After Stroke
Most stroke survivors have difficulties completing activities of daily living (ADLs) independently. However, few rehabilitation systems have focused on ADLs-related training for gross and fine motor function together. We propose an ADLs-based serious game rehabilitation system for the training of motor function and coordination of both arm and hand movement where the user performs corresponding ADLs movements to interact with the target in the serious game. A multi-sensor fusion model based on electromyographic (EMG), force myographic (FMG), and inertial sensing was developed to estimate users’ natural upper limb movement. Eight healthy subjects and three stroke patients were recruited in an experiment to validate the system’s effectiveness. The performance of different sensor and classifier configurations on hand gesture classification against the arm position variations were analyzed, and qualitative patient questionnaires were conducted. Results showed that elbow extension/flexion has a more significant negative influence on EMG-based, FMG-based, and EMG+FMG-based hand gesture recognition than shoulder abduction/adduction does. In addition, there was no significant difference in the negative influence of shoulder abduction/adduction and shoulder flexion/extension on hand gesture recognition. However, there was a significant interaction between sensor configurations and algorithm configurations in both offline and real-time recognition accuracy. The EMG+FMG-combined multi-position classifier model had the best performance against arm position change. In addition, all the stroke patients reported their ADLs-related ability could be restored by using the system. These results demonstrate that the multi-sensor fusion model could estimate hand gestures and gross movement accurately, and the proposed training system has the potential to improve patients’ ability to perform ADLs.