PSPairash Saiviroonporn

Pairash Saiviroonporn

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Pairash Saiviroonporn has a total of 38 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Development and internal validation of a semiautomated HRCT-based tool for quantification of interstitial lung disease in systemic sclerosis

    by C. Muangchan, S. Wonglaksanapimon, P. Thiravit, K. Butnian, P. Yodprom, A. Chomphuphun, N. Boonrueng, P. Saiviroonporn, S. Disayabutr, K. Teerapuncharoen


  • Open Access

    Detecting COVID-19 in chest X-ray images

    by Worapan Kusakunniran, Punyanuch Borwarnginn, Thanongchai Siriapisith, Sarattha Karnjanapreechakorn, Krittanat Sutassananon, Trongtum Tongdee, Pairash Saiviroonporn

    One reliable way of detecting coronavirus disease 2019 (COVID-19) is using a chest x-ray image due to its complications in the lung parenchyma. This paper proposes a solution for COVID-19 detection in chest x-ray images based on a convolutional neural network (CNN). This CNN-based solution is developed using a modified InceptionV3 as a backbone architecture. Self-attention layers are inserted to modify the backbone such that the number of trainable parameters is reduced and meaningful areas of COVID-19 in chest x-ray images are focused on a training process. The proposed CNN architecture is then learned to construct a model to classify COVID-19 cases from non-COVID-19 cases. It achieves sensitivity, specificity, and accuracy values of 93%, 96%, and 96%, respectively. The model is also further validated on the so-called other normal and abnormal, which are non-COVID-19 cases. Cases of other normal contain chest x-ray images of elderly patients with minimal fibrosis and spondylosis of the spine, whereas other abnormal cases contain chest x-ray images of tuberculosis, pneumonia, and pulmonary edema. The proposed solution could correctly classify them as non-COVID-19 with 92% accuracy. This is a practical scenario where non-COVID-19 cases could cover more than just a normal condition.


  • Open Access

    Classification of chest radiography from general radiography using deep learning approach

    by Trongtum Tongdee, Worapan Kusakunniran, Thanongchai Siriapisith, Pairash Saiviroonporn, Thanandon Imaromkul, Pakorn Yodprom


  • Open Access

    A clinical evaluation study of cardiothoracic ratio measurement using artificial intelligence

    by Pairash Saiviroonporn, Suwimon Wonglaksanapimon, Warasinee Chaisangmongkon, Isarun Chamveha, Pakorn Yodprom, Krittachat Butnian, Thanogchai Siriapisith, Trongtum Tongdee

    Background: Artificial intelligence, particularly the deep learning (DL) model, can provide reliable results for automated cardiothoracic ratio (CTR) measurement on chest X-ray (CXR) images. In everyday clinical use, however, this technology is usually implemented in a non-automated (AI-assisted) capacity because it still requires approval from radiologists. We investigated the performance and efficiency of our recently proposed models for the AI-assisted method intended for clinical practice. Methods: We validated four proposed DL models (AlbuNet, SegNet, VGG-11, and VGG-16) to find the best model for clinical implementation using a dataset of 7517 CXR images from manual operations. These models were investigated in single-model and combined-model modes to find the model with the highest percentage of results where the user could accept the results without further interaction (excellent grade), and with measurement variation within ± 1.8% of the human-operating range. The best model from the validation study was then tested on an evaluation dataset of 9386 CXR images using the AI-assisted method with two radiologists to measure the yield of excellent grade results, observer variation, and operating time. A Bland–Altman plot with coefficient of variation (CV) was employed to evaluate agreement between measurements. Results: The VGG-16 gave the highest excellent grade result (68.9%) of any single-model mode with a CV comparable to manual operation (2.12% vs 2.13%). No DL model produced a failure-grade result. The combined-model mode of AlbuNet + VGG-11 model yielded excellent grades in 82.7% of images and a CV of 1.36%. Using the evaluation dataset, the AlbuNet + VGG-11 model produced excellent grade results in 77.8% of images, a CV of 1.55%, and reduced CTR measurement time by almost ten-fold (1.07 ± 2.62 s vs 10.6 ± 1.5 s) compared with manual operation. Conclusion: Due to its excellent accuracy and speed, the AlbuNet + VGG-11 model could be clinically implemented to assist radiologists with CTR measurement.


  • Open Access

    An automated liver segmentation in liver iron concentration map using fuzzy c-means clustering combined with anatomical landmark data

    by Kittichai Wantanajittikul, Pairash Saiviroonporn, Suwit Saekho, Rungroj Krittayaphong, Vip Viprakasit

    To estimate median liver iron concentration (LIC) calculated from magnetic resonance imaging, excluded vessels of the liver parenchyma region were defined manually. Previous works proposed the automated method for excluding vessels from the liver region. However, only user-defined liver region remained a manual process. Therefore, this work aimed to develop an automated liver region segmentation technique to automate the whole process of median LIC calculation. 553 MR examinations from 471 thalassemia major patients were used in this study. LIC maps (in mg/g dry weight) were calculated and used as the input of segmentation procedures. Anatomical landmark data were detected and used to restrict ROI. After that, the liver region was segmented using fuzzy c-means clustering and reduced segmentation errors by morphological processes. According to the clinical application, erosion with a suitable size of the structuring element was applied to reduce the segmented liver region to avoid uncertainty around the edge of the liver. The segmentation results were evaluated by comparing with manual segmentation performed by a board-certified radiologist. The proposed method was able to produce a good grade output in approximately 81% of all data. Approximately 11% of all data required an easy modification step. The rest of the output, approximately 8%, was an unsuccessful grade and required manual intervention by a user. For the evaluation matrices, percent dice similarity coefficient (%DSC) was in the range 86–92, percent Jaccard index (%JC) was 78–86, and Hausdorff distance (H) was 14–28 mm, respectively. In this study, percent false positive (%FP) and percent false negative (%FN) were applied to evaluate under- and over-segmentation that other evaluation matrices could not handle. The average of operation times could be reduced from 10 s per case using traditional method, to 1.5 s per case using our proposed method. The experimental results showed that the proposed method provided an effective automated liver segmentation technique, which can be applied clinically for automated median LIC calculation in thalassemia major patients.


  • Open Access

    Cardiothoracic Ratio Measurement Using Artificial Intelligence: Observer and Method Validation Studies

    by Pairash Saiviroonporn, Kanchanaporn Rodbangyang, Trongtum Tongdee, Warasinee Chaisangmongkon, Pakorn Yodprom, Thanogchai Siriapisith, Suwimon Wonglaksanapimon, Phakphoom Thiravit

    Background Artificial Intelligence (AI) technique for cardiothoracic ratio (CTR) measurement is a promising tool that has been technically validated but not clinically evaluated on a large dataset. This study observes and validates AI and manual methods for CTR measurement on a large dataset and investigates the clinical utility of the AI method. Results Five thousand normal chest x-rays and 2,517 images with cardiomegaly and CTR values, were analyzed using manual, AI-assisted, and AI only methods. AI methods obtained CTR values from a VGG-16 U-Net model. An in-house software was used to aid the study and to record measurement time. Intra and inter-observer experiments were performed on manual and AI-assisted methods and the average of each method was employed in a method variation study. AI outcomes were graded in the AI-assisted method as excellent (accepted by both users independently), good (required adjustment), and poor (failed outcome). Bland-Altman plot with coefficient of variation (CV), and coefficient of determination (R-squared) were employed to evaluate agreement and correlation between measurements. Finally, the performance of a cardiomegaly classification test was evaluated using a CTR cutoff at the standard (0.5), optimum, and maximum sensitivity. Manual CTR measurements on cardiomegaly data were comparable to the previous radiologist reports (CV of 2.13% vs 2.04%). The observer and method variations from the AI method were about three times higher than from the manual method (CV of 5.78% vs 2.13%). AI assistance resulted in 40% excellent, 56% good, and 4% poor grading. AI assistance significantly improved agreement on inter-observer measurement compared to manual methods (CV; bias: 1.72%; -0.61% vs 2.13%; -1.62%) and was faster to perform (2.2 ± 2.4 secs vs 10.6 ± 1.5 secs). R-squared and classification-test were not reliable indicators to verify that the AI method could replace manual operation. Conclusion AI alone is not suitable to replace manual operation due to its high variation, but it is useful to assist the radiologist because it can reduce observer variation and operation time. Agreement of measurement should be used to compare AI and manual methods, rather than R-square or classification performance tests.

  • Open Access

    COVID-19 detection and heatmap generation in chest x-ray images

    by Worapan Kusakunniran, Punyanuch Borwarnginn, Krittanat Sutassananon, Trongtum Tongdee, Pairash Saiviroonporn, Sarattha Karnjanapreechakorn, Thanongchai Siriapisith

    Chest x-ray images could be used in an automatic image analysis for detecting and classifying abnormalities, including diseases of atelectasis, consolidation, infiltration, pneumothorax, edema, emphysema, fibrosis, effusion, pneumonia, pleural thickening, cardiomegaly, nodule mass, and hernia, as mentioned in the NIH chest x-ray dataset.1 On top of these diseases, which are commonly diagnosed using chest x-ray images, this paper focuses on the new disease of COVID-19 which causes lung damage and can also be detected in chest x-ray images.2 Several methods were proposed recently to address this research domain. Existing methods are reviewed below. All of them were developed based on the convolutional neural network (CNN).


  • Open Access

    Local Adaptation Improves Accuracy of Deep Learning Model for Automated X-Ray Thoracic Disease Detection : A Thai Study

    by Isarun Chamveha, Trongtum Tongdee, Pairash Saiviroonporn, Warasinee Chaisangmongkon

    Despite much promising research in the area of artificial intelligence for medical image diagnosis, there has been no large-scale validation study done in Thailand to confirm the accuracy and utility of such algorithms when applied to local datasets. Here we present a wide-reaching development and testing of a deep learning algorithm for automated thoracic disease detection, utilizing 421,859 local chest radiographs. Our study shows that convolutional neural networks can achieve remarkable performance in detecting 13 common abnormality conditions on chest X-ray, and the incorporation of local images into the training set is key to the model's success. This paper presents a state-of-the-art model for CXR abnormality detection, reaching an average AUROC of 0.91. This model, if integrated to the workflow, can result in up to 55.6% work reduction for medical practitioners in the CXR analysis process. Our work emphasizes the importance of investing in local research of medical diagnosis algorithms to ensure safe and efficient usage within the intended region.

  • Open Access

    Automated Cardiothoracic Ratio Calculation and Cardiomegaly Detection using Deep Learning Approach

    by Isarun Chamveha, Treethep Promwiset, Trongtum Tongdee, Pairash Saiviroonporn, Warasinee Chaisangmongkon

    We propose an algorithm for calculating the cardiothoracic ratio (CTR) from chest X-ray films. Our approach applies a deep learning model based on U-Net with VGG16 encoder to extract lung and heart masks from chest X-ray images and calculate CTR from the extents of obtained masks. Human radiologists evaluated our CTR measurements, and $76.5\%$ were accepted to be included in medical reports without any need for adjustment. This result translates to a large amount of time and labor saved for radiologists using our automated tools.


  • Myocardial perfusion cardiac magnetic resonance for the diagnosis of coronary artery disease: do we need rest images?

    by Rungroj Krittayaphong, Thananya Boonyasirinant, Pairash Saiviroonporn, Supaporn Nakyen, Prajak Thanapiboonpol, Ahthit Yindeengam, Suthipol Udompunturak

    Adenosine stress cardiovascular magnetic resonance (CMR) has been reported to be useful for the diagnosis of coronary artery disease (CAD). Most studies use rest and stress perfusion images. The objectives of this study were to determine (Barkhausen et al. in J Magn Reson Imaging 19(6):750–757, 1) the accuracy of visual assessment and myocardial perfusion reserve index (MPRI) in the diagnosis of CAD and (Rieber et al. in Fur Heart J 27(12):1465–1471, 2) the accuracy of analysis based on rest–stress and stress images. We enrolled patients with suspected CAD and referred them for coronary angiography (CAG). All the patients underwent adenosine stress CMR before CAG. Rest and stress perfusion images were analyzed by calculation of MPRI and visual assessment separately. Visual assessment was performed separately by using rest and stress images and by using only stress images. CAG was considered the gold standard. Sensitivity, specificity, and accuracy of both methods were calculated and compared. A total of 66 patients (mean age, 61.3 ± 11.7 years) were studied. Thirty-eight patients (57.6%) were diagnosed with CAD. The sensitivity and specificity for the diagnosis of CAD (≥50% stenosis) were 89.5 and 78.6% for MPRI, 76.3 and 75% for stress–rest visual method, and 86.8 and 75% for stress visual method, respectively. CMR perfusion had a relatively lower accuracy in patients with left ventricular systolic dysfunction, high left ventricular mass, or presence of late gadolinium enhancement than in patients without those CMR findings. Visual assessment of stress image of CMR perfusion is accurate and comparable to MPRI for the detection of CAD.