Deepchandra Joshi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Deepchandra Joshi has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Satyananda Kar
Department of Energy Science and Engineering, Indian Institute of Technology Delhi , Hauz Khas, New Delhi 110016
2 shared publications Shaikh Ziauddin Ahammad
2 shared publicationsG. Veda Prakash
1 shared publication- G. Veda Prakash
Department of Energy Science and Engineering, Indian Institute of Technology Delhi , Hauz Khas, New Delhi 110016, India
1 shared publication - Shaikh Ziauddin Ahammad
Department of Biochemical Engineering and Biotechnology, Indian Institute of Technology Delhi, New Delhi, 110016, India
1 shared publication T R Sreekrishnan
Department of Biochemical Engineering and Biotechnology, Indian Institute of Technology Delhi, New Delhi 110016, India
1 shared publication
Latest Publications
- Open Access
- 13 April 2026
- Published by Elsevier in SSRN Electronic Journal
Design and evaluation of a large area lateral Dielectric Barrier Discharge plasma reactor for wastewater treatment
A large-area Lateral Dielectric Barrier Discharge Plasma (LDP) reactor was developed to enhance plasma-liquid interfacial area and improve the utilization of plasma-generated reactive species for contaminants degradation. Unlike conventional DBD jet systems, the lateral electrode configuration distributed the discharge uniformly along the full electrode length, thereby expanding the effective plasma zone. Reactor performance was first evaluated using Rhodamine B (Rd. B) and Caffeine as model contaminants. A threefold increase in plasma area (single- to triple-branch configuration), increased Rd. B degradation from 71 to 100% and caffeine degradation from 57 to 91%, while decreasing the electrical energy per order from 2571 to 230 kWh/m3 for Rd. B and from 3720 to 430 kWh/m3 for caffeine. Feed-gas composition strongly governed reactive-species chemistry: argon produced the highest dissolved •OH radical concentration, whereas oxygen generated the greatest H2O2 and O3 concentrations, indicating a shift toward long-lived oxidants. Plasma exhaust-gas recirculation further intensified treatment, increasing degradation rate constants from 0.18 to 0.53 1/min for Rd. B and from 0.14 to 0.44 1/min for caffeine. Under optimized conditions, the reactor achieved 71% average pharmaceutical removal in raw wastewater and complete removal in pretreated wastewater within 30 min, highlighting its promise as a plasma-only polishing strategy for treated wastewater effluents.
- 13 April 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessDesign and evaluation of a large area lateral Dielectric Barrier Discharge plasma reactor for wastewater treatment
A large-area Lateral Dielectric Barrier Discharge Plasma (LDP) reactor was developed to enhance plasma-liquid interfacial area and improve the utilization of plasma-generated reactive species for contaminants degradation. Unlike conventional DBD jet systems, the lateral electrode configuration distributed the discharge uniformly along the full electrode length, thereby expanding the effective plasma zone. Reactor performance was first evaluated using Rhodamine B (Rd. B) and Caffeine as model contaminants. A threefold increase in plasma area (single- to triple-branch configuration), increased Rd. B degradation from 71 to 100% and caffeine degradation from 57 to 91%, while decreasing the electrical energy per order from 2571 to 230 kWh/m3 for Rd. B and from 3720 to 430 kWh/m3 for caffeine. Feed-gas composition strongly governed reactive-species chemistry: argon produced the highest dissolved •OH radical concentration, whereas oxygen generated the greatest H2O2 and O3 concentrations, indicating a shift toward long-lived oxidants. Plasma exhaust-gas recirculation further intensified treatment, increasing degradation rate constants from 0.18 to 0.53 1/min for Rd. B and from 0.14 to 0.44 1/min for caffeine. Under optimized conditions, the reactor achieved 71% average pharmaceutical removal in raw wastewater and complete removal in pretreated wastewater within 30 min, highlighting its promise as a plasma-only polishing strategy for treated wastewater effluents.
- 27 July 2022
- Published by IOP Publishing in Plasma Science and Technology
- Vol. 24 (10) , 105501
Development of low power non-thermal plasma jet and optimization of operational parameters for treating dyes and emerging contaminants
Non-thermal plasma has emerged as an effective treatment system against the latest class of highly recalcitrant and toxic environmental pollutants termed emerging contaminants (ECs). In the present work, a detailed experimental study is carried out to evaluate the efficacy of a non-thermal plasma jet with two dyes, Rd. B and Met. Blue, as model contaminants. The plasma jet provided a complete dye decoloration in 30 min with an applied voltage of 6.5 kVp−p. ·OH, having the highest oxidation potential, acts as the main reactive species, which with direct action on contaminants also acts indirectly by getting converted into H2O2 and O3. Further, the effect of critical operational parameters viz, sample pH, applied voltage (4.5‒6.5 kVp−p), conductivity (5‒20 mS cm−1), and sample distance on plasma treatment efficacy was also examined. Out of all the assessed parameters, the applied voltage and sample conductivity was found to be the most significant operating parameters. A high voltage and low conductivity favored the dye decoloration, while the pH effect was not that significant. To understand the influence of plasma discharge gas on treatment efficacy, all the experiments are conducted with argon and helium gases under the fixed geometrical configuration. Both the gases provided a similar dye decoloration efficiency. The DBD plasma system with complete dye removal also rendered maximum mineralization of 73% for Rd. B, and 60% for Met. Blue. Finally, the system’s efficiency against the actual ECs (four pharmaceutical compounds, viz, metformin, atenolol, acetaminophen, and ranitidine) and microbial contaminant (E. coli) was also tested. The system showed effectivity in the complete removal of targeted pharmaceuticals and a log2.5 E. coli reduction. The present systematic characterization of dye degradation could be of interest to large communities working towards commercializing plasma treatment systems.
- 27 July 2022
- Published by IOP Publishing in Plasma Science and Technology
- Vol. 24 (10) , 105501
Development of low power non-thermal plasma jet and optimization of operational parameters for treating dyes and emerging contaminants
Non-thermal plasma has emerged as an effective treatment system against the latest class of highly recalcitrant and toxic environmental pollutants termed emerging contaminants (ECs). In the present work, a detailed experimental study is carried out to evaluate the efficacy of a non-thermal plasma jet with two dyes, Rd. B and Met. Blue, as model contaminants. The plasma jet provided a complete dye decoloration in 30 min with an applied voltage of 6.5 kVp−p. ·OH, having the highest oxidation potential, acts as the main reactive species, which with direct action on contaminants also acts indirectly by getting converted into H2O2 and O3. Further, the effect of critical operational parameters viz, sample pH, applied voltage (4.5‒6.5 kVp−p), conductivity (5‒20 mS cm−1), and sample distance on plasma treatment efficacy was also examined. Out of all the assessed parameters, the applied voltage and sample conductivity was found to be the most significant operating parameters. A high voltage and low conductivity favored the dye decoloration, while the pH effect was not that significant. To understand the influence of plasma discharge gas on treatment efficacy, all the experiments are conducted with argon and helium gases under the fixed geometrical configuration. Both the gases provided a similar dye decoloration efficiency. The DBD plasma system with complete dye removal also rendered maximum mineralization of 73% for Rd. B, and 60% for Met. Blue. Finally, the system’s efficiency against the actual ECs (four pharmaceutical compounds, viz, metformin, atenolol, acetaminophen, and ranitidine) and microbial contaminant (E. coli) was also tested. The system showed effectivity in the complete removal of targeted pharmaceuticals and a log2.5 E. coli reduction. The present systematic characterization of dye degradation could be of interest to large communities working towards commercializing plasma treatment systems.
- 17 May 2022
- Published by Taylor & Francis
- p. 3-23
Occurrence, fate, and plasma treatment of emerging contaminants in groundwater
Water pollution is a serious worldwide concern, and it has further elevated with the finding of emerging contaminants (ECs). After surface water, we have now started finding their groundwater fingerprints. Groundwater is an essential source of fresh water, and its contamination will affect the aquatic ecosystem. Groundwater conditions favor the persistency of ECs, due to which ECs present in groundwater become a legacy source of pollution. The groundwater conditions are different, and with the compound’s physicochemical property, the geography, flow pathways, and subsurface conditions also influence the fate of ECs in groundwater. In the absence of any rectification method for groundwater, its treatment will be very challenging. Therefore, groundwater contamination requires increased awareness and development of proper regulations. With its negative effect on human and environmental health, groundwater contamination will also impact a country’s economy. This literature will be focused on the current scenario of the ECs in groundwater, the path followed by them to reach the groundwater, and after reaching their the type of behavior they show and their fate. Additionally, the role of the plasma system for the effective removal of ECs has been explored.
- 17 May 2022
- Published by Taylor & Francis
- p. 3-23
Occurrence, fate, and plasma treatment of emerging contaminants in groundwater
Water pollution is a serious worldwide concern, and it has further elevated with the finding of emerging contaminants (ECs). After surface water, we have now started finding their groundwater fingerprints. Groundwater is an essential source of fresh water, and its contamination will affect the aquatic ecosystem. Groundwater conditions favor the persistency of ECs, due to which ECs present in groundwater become a legacy source of pollution. The groundwater conditions are different, and with the compound’s physicochemical property, the geography, flow pathways, and subsurface conditions also influence the fate of ECs in groundwater. In the absence of any rectification method for groundwater, its treatment will be very challenging. Therefore, groundwater contamination requires increased awareness and development of proper regulations. With its negative effect on human and environmental health, groundwater contamination will also impact a country’s economy. This literature will be focused on the current scenario of the ECs in groundwater, the path followed by them to reach the groundwater, and after reaching their the type of behavior they show and their fate. Additionally, the role of the plasma system for the effective removal of ECs has been explored.