PSPaul Schmalenberg

Paul Schmalenberg

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Paul Schmalenberg has a total of 46 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Non-invasive cardiac sensing via an acoustic Helmholtz resonator cavity with electrocardiogram waveform reconstruction

    by Paul D. Schmalenberg, Hossein Hamidi Shishavan, Parveen Singh, Kleanthis Avramidis, Frederico M. Q. Severgnini, Bryan Pardo, Taehwa Lee, Ercan M. Dede

  • Scattering-free subwavelength acoustic direction sensing via virtual acoustic resonance

    by Taehwa Lee, Ziqi Yu, Hyung-Suk Kwon, Xiaopeng Li, Xiaoshi Su, Paul Schmalenberg, Ercan M. Dede, Hideo Iizuka

    Conventional direction sensing relies on digital phase extraction after analog-to-digital conversion, which becomes computationally demanding as subwavelength phase differences shrink. Here, we introduce a virtual resonance approach that performs phase-to-amplitude transduction in the analog front-end before heavy digital post-processing. The mechanism is based on interference between symmetric and antisymmetric modes in conservatively coupled electronic resonators, enabling robust amplitude asymmetry from small phase gradients while preserving a scattering-free sensing field. Experimentally, a compact acoustic imaging system achieves high-fidelity direction-of-arrival estimation with a mean error of ∼2.5° at subwavelength spacing below λ/8.

  • Open Access

    Inverse‐Designed Nanophotonic Structures for On‐Chip Excitation and Broadband Emission Extraction in Diamond Quantum Spin Sensing

    by Yuqing Zhou, Tsuyoshi Nomura, Yuki Sato, Makoto Nakai, Paul D. Schmalenberg, Ercan M. Dede

    Diamond nitrogen‐vacancy based solid‐state quantum spin sensors on a photonic integrated circuit offer exceptional sensitivity, high spatial resolution, and the potential for substantial device miniaturization. Efficient extraction of broadened phonon sideband emission is particularly important for spin sensing, where measurements rely on fluorescence contrast between spin states rather than indistinguishable photons. However, simultaneous high‐efficiency delivery of excitation light to the nitrogen‐vacancy site and collection of its broad phonon sideband emission remains challenging. This work introduces practical nanophotonic structures using a foundry‐compatible material stack and a fabrication‐constrained inverse design method. An improved regularization scheme enforces minimum feature sizes in both core and cladding. The optimized sensing unit integrates two compact components on a silicon nitride layer: an emitter and a broadband directional coupler. The optimized emitter enhances green (532 nm) excitation while efficiently extracting and coupling broadband red (620–760 nm) emission into a single‐mode waveguide, yielding up to a 3‐fold increase in guided‐mode power relative to a straight ridge waveguide baseline with the same nanodiamond opening. The optimized directional coupler routes 80% of the phonon sideband to the detection port while enabling efficient excitation delivery. System‐level simulation and robustness analysis confirm performance and tolerance to nanodiamond placement uncertainty.

  • Open Access

    Physics-informed multi-fidelity surrogate modeling of fluid flow in porous media

    by Reza Behrou, Hadi Mansourifar, Yuqing Zhou, Siwen Wang, Paul D. Schmalenberg, Chen Ling, Ercan M. Dede

    Predicting the behavior of a fluid as it flows through porous media is critical for electrochemical devices and other scientific, industrial, and environmental applications. The main challenge lies in accurately capturing the complex, multi-scale fluid flow behavior through irregular porous microstructures, all while maintaining computational efficiency. In this paper, we introduce a multi-fidelity surrogate model that predicts the high-fidelity flow field state variables in explicit porous media microstructures with minimal computational cost. Our approach begins by collecting both low-fidelity and high-fidelity simulation data to train the surrogate model. The former low-fidelity data are obtained from numerical simulations of fluid flowing through macro-scale structures having homogenized effective material properties. On the other hand, the latter high-fidelity data include geometric details of the dehomogenized explicit porous media microstructure. This technique combines the detailed accuracy of high-fidelity data with the computational efficiency of low-fidelity data, thus enhancing the model performance. In addition, we integrate physics-informed neural networks into the surrogate modeling process, embedding physical laws derived from the Navier–Stokes equations that govern fluid flow. This multi-scale, multi-fidelity approach offers a precise and cost-effective solution for predicting the fluid flow velocity and pressure fields in the porous media. For relevant porous media fluid flow applications, we show a ∼103× faster solution in terms of increased computational speed for a given model with reasonable representative accuracy of the solution, within a range of ∼5%–20% for velocity and ≤10% for pressure fields.


  • Open Access

    Electrodermal Activity Monitoring With Flexible Dry Electrodes and AC Measurement

    by Hossein Hamidi Shishavan, Frederico Marcolino Quintao Severgnini, Parveen Singh, Paul Schmalenberg, Ercan M. Dede

    Wearable sensing technology has transformed the healthcare landscape, shifting from traditional hospital settings to more personalized home-based care. One prominent focus lies in evaluating autonomic nervous system activity, which has been made possible by integrating electrodermal activity (EDA) monitoring into wearable devices. In this study, we thoroughly explored measurement methods and electrode designs to identify the optimal solution for accurate EDA monitoring. The state-of-the-art method utilizes direct current (DC) for measurement, which fails to capture the skin’s capacitive properties. Therefore, we explore using alternating current (AC) with flexible dry electrodes and examine the influence of electrode geometry (including gap size), material, and anatomical locations on bio-signal quality. Custom dry electrodes with interdigitated design and gold plates exhibited promising results, offering lower impedance, shorter stabilization periods, and higher correlation with the standard pre-gelled Ag/AgCl electrodes. We found electrode-skin contact area critical in determining the signal quality for dry electrodes. We further compared the performance of the AC method across various designs utilizing both handcrafted and deep learning extracted features. The results demonstrated that the constant-amplitude, AC-voltage exosomatic method significantly enhances EDA measurements. Specifically, for the application of cognitive stress detection, utilizing phase angle information improved the accuracy by 12.72% compared to the DC method, resulting in an overall accuracy of 83.54% among 10 participants. Thus, employing an AC-based approach with an optimized dry electrode design could serve as a viable and accurate alternative to wet electrodes for long-duration monitoring.


  • Dual-ring resonator design for enhanced thermal isolation and optical performance

    by Ercan M. Dede, Jiahui Wang, Paul D. Schmalenberg, Sean P. Rodrigues, Shanhui Fan

    We report on the design of a dual-ring resonator for enhanced thermal isolation between rings and associated improved optical performance. Two 20 µm diameter silicon (Si) ring resonators, each embedded in silicon dioxide (SiO2) and having a semi-circular arc-shaped overclad heater, are spaced apart by 200 nm as a base configuration. The optimization of the topology of a surrounding 4 µm deep custom air trench results in a 10.3°C increase in the steady-state average temperature of a specified heated ring relative to the thermal performance of the baseline structure. An additional thermal isolation trench between rings in combination with a thermally conductive overlay structure is also investigated and shown to provide further enhanced anisotropic heat flow control and device transient response. From an optical perspective, the custom trench plus thermal overlay strategy for heat transfer enhancement reduces the throughput at the device drop port by −3.36 dB across the double-ring structure and produces a 37% larger difference between ring resonances when comparing performance with a simply heated, non-etched device design.


  • Open Access

    Evolution of quantum spin sensing: From bench-scale ODMR to compact integrations

    by Shahriar Esmaeili, Paul Schmalenberg, Songtao Wu, Yuqing Zhou, Sean Rodrigues, Naveed Hussain, Taishi Kimura, Yukihiro Tadokoro, Shougo Higashi, Debasish Banerjee, et al.

    This paper provides a comprehensive review of quantum spin sensing with a focus on the nitrogen vacancy (NV) center in diamond. Beginning with the discovery of optically detected magnetic resonance in NV centers, we trace the evolution of this technology and its integration with complementary metal-oxide-semiconductor technology, marking a significant advancement in measurement science. The unique optical and spin properties of NV centers, operational at room temperature and under ambient conditions, have broadened their application spectrum, notably in magnetometry for nanoscale magnetic field detection. This work describes the transition from isolated NV centers to dense ensembles, highlighting the challenges and advancements in microfabrication and nanofabrication that have facilitated the integration of these centers with photonic structures and electronic devices. The efficient readout of NV spin states and the challenges in miniaturization are addressed, showcasing the development of compact, portable quantum sensors. We also discuss the potential impact of these sensors in various domains, including vehicle sensor systems and biomedical applications, underscoring the significance of environmental influences on magnetometric readings.


  • Thinned array distribution with grating lobe canceller at any scan angle for automotive radar applications

    by Masato Kohtani, Sungwoo Cha, Paul Schmalenberg, Jae Lee, Linjie Li, Toshihiko Takahata, Shinji Yamaura, Toshihiko Matsuoka, Gabriel M. Rebeiz

    A novel thinned antenna element distribution for cancelling grating lobes (GLs) as well as for reducing phase shifters (PSs) is presented for a two-dimensional phased-array automotive radar application. First, an efficient clustering technique of vertical adjacent elements is employed with array thinning for a PS reduction of 66.7%. In the proposed distribution, several single-element radiators (non-clustered antenna elements) are placed in the vertical direction with specific spacing in a grid of 16 × 12 (192) elements with λ/2 pitch. This disrupts the periodicity of phase-centers after element-clustering and takes a role as steerable GL canceller with capabilities of tracking and nullifying the GL at any scan angle. The proposed distribution enables beam steering up to ±60° in the azimuth plane, as well as ±25° in the elevation plane with cancelled GL and sidelobes. Furthermore, the proposed distribution has been efficiently calibrated with all elements activated by introducing the code division multiple access technique. To the best of the authors’ knowledge, this work represents the first fully calibrated state-of-the-art thinned distribution phased-array including a novel steerable GL canceller to track and nullify GLs.


  • Open Access

    Acoustic resonators for detecting low frequency events

    by Paul Schmalenberg, Parveen Singh, Frederico Severgnini, Ercan Dede

    Acoustic resonators and related concepts have long been the subject of research for acoustic filtering in free space or energy harvesting applications. In this work, we instead apply acoustic resonators to low frequency (< 50 Hz) non-contact bio-signal sensing within a vehicle cabin. We describe our approach to the design of the resonator and method of simulation in this low frequency regime. Validation of select designs through experiments in both free space and using a coupled bodies method is discussed. We also demonstrate the bio-signal collection in situ and discuss challenges associated with a real-world, noisy, dynamic environment. Future work including signal processing of noisy data to recover the base bio-signal and ideas for miniaturization of the device are touched upon.

  • Open Access

    Optimization of Planar Phased Arrays for Vehicles

    by Paul Schmalenberg, Ercan M. Dede, Tsuyoshi Nomura, Shinji Nishiwaki

    Radar sensors are used for the detection of objects surrounding a vehicle to enable advanced driver assistance systems. Wide angle azimuth field-of-view (FOV) sensor having high angular resolution is beneficial but presents challenges for low-cost implementation where element to element spacing may be larger than one-half wavelength. Irregular placement of array elements in a two-dimensional (2-D) array can achieve low-cost targets but may generate large side lobes if done without care. We introduce an optimization method to determine placement of array elements in a vehicular volumetric beam scanning radar to minimize side lobe power for typical automotive beam steering angles. Optimization with array constraints is realized using a gradient-based non-linear programming technique. Optimization is accelerated by extending uv-projection planes beyond the unit circle. For a grating lobe-free scan area based on vehicular applications, the azimuth scanning FOV is increased by $11^{\circ }$ bidirectionally to $\pm 54^{\circ }$ compared to a reference triangular grid array with 24 elements. The validity of an antenna design generated using the optimization method is established by a three-dimensional (3-D) electromagnetic wave simulation of a representative optimized array configuration.