Ana Aliaga-Mariñas
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ana Aliaga-Mariñas has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- César Cayo-Rojas
School of Stomatology, Universidad Privada San Juan Bautista, Lima, Peru
2 shared publications - Leonor Castro-Ramirez
School of Stomatology, Universidad Privada San Juan Bautista, Lima, Peru
2 shared publications - Luis Cervantes-Ganoza
School of Stomatology, Universidad Privada San Juan Bautista, Lima, Peru, upsjb.edu.pe
2 shared publications - Marysela Ladera-Castañeda
School of Stomatology, Universidad Privada San Juan Bautista, Lima, Peru
2 shared publications - Alberto Cornejo-Pinto
Faculty of Dentistry and Postgraduate School, Research Group “Salud Pública-Salud Integral”, Universidad Nacional Federico Villarreal, Lima, Peru
1 shared publication - Ann Carrillo-Marcos
School of Stomatology, Universidad Privada San Juan Bautista, 15066 Lima, Peru
1 shared publication
Latest Publications
- Open Access
- 1 January 2024
- Published by Universidad de Los Andes, Venezuela in Revista GICOS
- Vol. 9 (2) , 27-39
Factores de riesgo de caries dental en niños preescolares con fisura de labio y paladar
Objetivo: identificar los factores de riesgo de caries dental en niños preescolares con labio y paladar fisurado. Metodología: estudio de tipo analítico transversal donde participaron 70 niños de 3 a 6 años con FLAP que fueron atendidos por el servicio de odontopediatría de la Organización No Gubernamental Qorito (Lima-Perú), de enero a diciembre del 2022. Las variables analizadas fueron caries dental, higiene oral, dieta, tipo de fisura, sexo, edad. Los análisis aplicados fueron la evaluación de Spearman, la prueba de Chi cuadrado y la regresión logística múltiple. Resultados: la prevalencia de caries dental en niños con FLAP fue del 92,9%. Para esto se empleó un índice que codifica los dientes deciduos como cariados, extraídos y obturados (CEOD) con manchas blancas. Además, se encontró que el tipo de fisura es un factor de riesgo para la caries dental con un (OR) de 3,15. Conclusión: la caries dental tiene una relación significativa con una deficiente higiene oral. A su vez, los niños con labio y paladar fisurado con una buena higiene oral tenían menos probabilidades de desarrollar caries dental que aquellos con una higiene oral deficiente.
- 1 January 2024
- Published by Universidad de Los Andes, Venezuela in Revista GICOS
- Vol. 9 (2) , 27-39
Open AccessFactores de riesgo de caries dental en niños preescolares con fisura de labio y paladar
Objetivo: identificar los factores de riesgo de caries dental en niños preescolares con labio y paladar fisurado. Metodología: estudio de tipo analítico transversal donde participaron 70 niños de 3 a 6 años con FLAP que fueron atendidos por el servicio de odontopediatría de la Organización No Gubernamental Qorito (Lima-Perú), de enero a diciembre del 2022. Las variables analizadas fueron caries dental, higiene oral, dieta, tipo de fisura, sexo, edad. Los análisis aplicados fueron la evaluación de Spearman, la prueba de Chi cuadrado y la regresión logística múltiple. Resultados: la prevalencia de caries dental en niños con FLAP fue del 92,9%. Para esto se empleó un índice que codifica los dientes deciduos como cariados, extraídos y obturados (CEOD) con manchas blancas. Además, se encontró que el tipo de fisura es un factor de riesgo para la caries dental con un (OR) de 3,15. Conclusión: la caries dental tiene una relación significativa con una deficiente higiene oral. A su vez, los niños con labio y paladar fisurado con una buena higiene oral tenían menos probabilidades de desarrollar caries dental que aquellos con una higiene oral deficiente.
- Open Access
In Vitro Color Stability Evaluation of Three Polished and Unpolished Nanohybrid Resin Composites Immersed in a 0.12% Chlorhexidine-Based Mouthwash at Different Times
The use of chlorhexidine-based mouthwashes on resin composites with rough surfaces can cause discoloration which compromises the esthetic of patients. The present study aimed to evaluate the in vitro color stability of Forma (Ultradent Products, Inc., South Jordan), Tetric N-Ceram (Ivoclar Vivadent, Schaan, Liechtenstein) and Filtek Z350XT (3M, ESPE, St. Paul, MN, USA) resin composites, with and without polishing, after being immersed in a 0.12% chlorhexidine (CHX)-based mouthwash at different times. The present in vitro experimental and longitudinal study used 96 nanohybrid resin composite blocks (Forma, Tetric N-Ceram and Filtek Z350XT) 8 mm in diameter and 2 mm thick, evenly distributed. Each resin composite group was divided into two subgroups (n = 16) with and without polishing and then immersed in a 0.12% CHX-based mouthwash for 7, 14, 21 and 28 days. Color measurements were performed with a calibrated digital spectrophotometer. Nonparametric tests were used to compare independent (Mann–Whitney U and Kruskal–Wallis) and related (Friedman) measures. In addition, the Bonferroni post hoc correction was used considering a significance level of p < 0.05. All polished and unpolished resin composites presented color variation < 3.3 when immersed for up to 14 days in 0.12% CHX-based mouthwash. The polished resin composite with the lowest color variation (ΔE) values over time was Forma, and the one with the highest values was Tetric N-Ceram. When comparing the color variation (ΔE) over time, it was observed that the three resin composites, with and without polishing, presented a significant change (p < 0.001), although these changes in color variation (ΔE) were evident from 14 days between each color acquisition (p < 0.05). The unpolished Forma and Filtek Z350XT resin composites showed significantly more color variation than the same polished ones at all times when immersed in a 0.12% CHX-based mouthwash for 30 s daily. In addition, every 14 days, all three resin composites with and without polishing showed a significant color change, while, every 7 days, color stability was maintained. All the resin composites showed clinically acceptable color stability when exposed for up to 14 days to the above-mentioned mouthwash.
Open AccessIn Vitro Color Stability Evaluation of Three Polished and Unpolished Nanohybrid Resin Composites Immersed in a 0.12% Chlorhexidine-Based Mouthwash at Different Times
The use of chlorhexidine-based mouthwashes on resin composites with rough surfaces can cause discoloration which compromises the esthetic of patients. The present study aimed to evaluate the in vitro color stability of Forma (Ultradent Products, Inc., South Jordan), Tetric N-Ceram (Ivoclar Vivadent, Schaan, Liechtenstein) and Filtek Z350XT (3M, ESPE, St. Paul, MN, USA) resin composites, with and without polishing, after being immersed in a 0.12% chlorhexidine (CHX)-based mouthwash at different times. The present in vitro experimental and longitudinal study used 96 nanohybrid resin composite blocks (Forma, Tetric N-Ceram and Filtek Z350XT) 8 mm in diameter and 2 mm thick, evenly distributed. Each resin composite group was divided into two subgroups (n = 16) with and without polishing and then immersed in a 0.12% CHX-based mouthwash for 7, 14, 21 and 28 days. Color measurements were performed with a calibrated digital spectrophotometer. Nonparametric tests were used to compare independent (Mann–Whitney U and Kruskal–Wallis) and related (Friedman) measures. In addition, the Bonferroni post hoc correction was used considering a significance level of p < 0.05. All polished and unpolished resin composites presented color variation < 3.3 when immersed for up to 14 days in 0.12% CHX-based mouthwash. The polished resin composite with the lowest color variation (ΔE) values over time was Forma, and the one with the highest values was Tetric N-Ceram. When comparing the color variation (ΔE) over time, it was observed that the three resin composites, with and without polishing, presented a significant change (p < 0.001), although these changes in color variation (ΔE) were evident from 14 days between each color acquisition (p < 0.05). The unpolished Forma and Filtek Z350XT resin composites showed significantly more color variation than the same polished ones at all times when immersed in a 0.12% CHX-based mouthwash for 30 s daily. In addition, every 14 days, all three resin composites with and without polishing showed a significant color change, while, every 7 days, color stability was maintained. All the resin composites showed clinically acceptable color stability when exposed for up to 14 days to the above-mentioned mouthwash.
- Open Access
The Microhardness and Surface Roughness Assessment of Bulk-Fill Resin Composites Treated with and without the Application of an Oxygen-Inhibited Layer and a Polishing System: An In Vitro Study
The aim of this study was to assess the microhardness and surface roughness of bulk-fill resin composites treated with and without the application of an oxygen-inhibited layer (OIL) and a polishing system. This in vitro experimental study consisted of 72 resin composite blocks divided into three groups: Tetric N-Ceram Bulk Fill, Opus Bulk Fill APS, and Filtek Bulk Fill. Each resin composite group was further divided into two subgroups: with and without OIL control. Subsequently, surface roughness and microhardness were measured before and after polishing. A t-test was used to compare independent and related measures. For the intergroup comparison of variation before and after polishing, the Kruskal–Wallis test with Bonferroni post hoc was used considering a significance level of p < 0.05. When comparing surface roughness, significant differences were observed between Opus Bulk Fill resin composite with and without OIL control (p = 0.003) before polishing. The same occurred when comparing Tetric N-Ceram resin composite with and without OIL control (p = 0.039) after polishing. In addition, the surface roughness of Filtek Bulk Fill, Opus Bulk Fill, and Tetric N-Ceram Bulk Fill resin composites, with and without OIL control, decreased significantly after polishing (p < 0.001), while surface microhardness significantly increased (p < 0.05), with the exception of Opus Bulk Fill resin with OIL control (p = 0.413). In conclusion, OIL control and polishing significantly improved the surface roughness and surface microhardness of Filtek Bulk Fill and Tetric N-Ceram Bulk Fill resin composites. However, in the case of Opus Bulk Fill resin composite, only its surface roughness was significantly improved.
Open AccessThe Microhardness and Surface Roughness Assessment of Bulk-Fill Resin Composites Treated with and without the Application of an Oxygen-Inhibited Layer and a Polishing System: An In Vitro Study
The aim of this study was to assess the microhardness and surface roughness of bulk-fill resin composites treated with and without the application of an oxygen-inhibited layer (OIL) and a polishing system. This in vitro experimental study consisted of 72 resin composite blocks divided into three groups: Tetric N-Ceram Bulk Fill, Opus Bulk Fill APS, and Filtek Bulk Fill. Each resin composite group was further divided into two subgroups: with and without OIL control. Subsequently, surface roughness and microhardness were measured before and after polishing. A t-test was used to compare independent and related measures. For the intergroup comparison of variation before and after polishing, the Kruskal–Wallis test with Bonferroni post hoc was used considering a significance level of p < 0.05. When comparing surface roughness, significant differences were observed between Opus Bulk Fill resin composite with and without OIL control (p = 0.003) before polishing. The same occurred when comparing Tetric N-Ceram resin composite with and without OIL control (p = 0.039) after polishing. In addition, the surface roughness of Filtek Bulk Fill, Opus Bulk Fill, and Tetric N-Ceram Bulk Fill resin composites, with and without OIL control, decreased significantly after polishing (p < 0.001), while surface microhardness significantly increased (p < 0.05), with the exception of Opus Bulk Fill resin with OIL control (p = 0.413). In conclusion, OIL control and polishing significantly improved the surface roughness and surface microhardness of Filtek Bulk Fill and Tetric N-Ceram Bulk Fill resin composites. However, in the case of Opus Bulk Fill resin composite, only its surface roughness was significantly improved.