Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ziyad Aloqalaa has a total of 22 co-authors. Here are the top co-authors by number of shared publications:

  • Ali Saad

    Department of Biomedical Technology, College of Applied Medical Sciences, King Saud University, Riyadh 11433, Saudi Arabia

    2 shared publications
  • Khalid Alhussaini

    Department of Biomedical Technology, College of Applied Medical Sciences, King Saud University, P.O. Box 10219, Riyadh 11433, Saudi Arabia

    2 shared publications
  • Mohammed Almijalli

    Department of Biomedical Technology, College of Applied Medical Sciences, King Saud University, Riyadh 11433, Saudi Arabia

    2 shared publications
  • Omar Altwijri

    Department of Biomedical Technology, College of Applied Medical Sciences, King Saud University, Riyadh 11433, Saudi Arabia

    2 shared publications
  • Abdulaziz S. Fakhouri

    Department of Biomedical Technology, College of Applied Medical Sciences, King Saud University, Riyadh, Saudi Arabia

    1 shared publication
  • Abdulsalam A. Al-Tamimi

    Department of Industrial Engineering, College of Engineering, King Saud University, Riyadh, Saudi Arabia

    1 shared publication

Latest Publications

  • Open Access

    3D-Printed Flexible Bending Sensors and the Effects of Using Different Conductive Track Geometries

    by Ziyad Aloqalaa

    Currently, humans live in a world of digital transformation, and sensors are essential for converting physical measurements to digital data. Conventional sensors often lack flexibility, leading to fragility and challenges in adaptation, particularly on complex and irregular surfaces. Flexible sensors can address these issues by providing stretchability and adaptability to their applications. Various techniques have been employed to develop flexible sensors; however, three-dimensional (3D) printing has gained popularity because of its ability to fabricate complex and integrated shapes at a low cost. Fused deposition modeling (FDM) is a widely utilized 3D-printing technique that holds significant potential for the development of flexible sensors utilizing flexible filaments, including thermoplastic polyurethanes (TPUs). TPU filaments typically consist of flexible thermoplastics that are non-conductive composites. However, electrically conductive versions can be developed by incorporating carbon-based composites, thereby enabling their use as functional sensors. This study investigated the influence of trace geometry on the electromechanical performance of 3D-printed flexible bending sensors. Three distinct trace configurations were designed and fabricated using a commercially available conductive TPU filament. These configurations included vertical strain gauge, horizontal strain gauge, and sinusoidal patterns. Three-point bending tests were conducted to characterize these sensors. The experimental results demonstrated a fundamental trade-off between the sensor sensitivity and electromechanical stability, which is mainly influenced by the geometrical configurations. The configuration of the vertical strain gauge achieved the highest sensitivity, with an average gauge factor (GF) in the range of −6.70 to −7.29. However, this vertical strain gauge resulted in a high mean hysteresis of 60.22%. In contrast, the sinusoidal design resulted in the highest linear predictability (R2 = 0.9183) and the lowest mean linearity error of 26.82%, even though it exhibited a lower sensitivity compared to the vertical strain gauge (GF in the range of −1.98 to −2.23). The horizontal gauge configuration performed relatively poorly across all metrics, except for the mean hysteresis, which was the lowest among the three designs (mean hysteresis = 26.66%). These findings suggest that the sinusoidal sensor is advisable for applications prioritizing overall performance metrics. In contrast, if sensitivity is the primary consideration, a vertical strain gauge sensor is more suitable. This study provides design guidelines for selecting optimal printing structures, especially in applications such as soft robotics, wearable electronics, and structural health monitoring, where consistent displacement tracking is required.

  • Open Access

    Evaluation of 3D-Printed Dry Electrodes for Surface Electromyography in Dynamic Muscle Assessment

    by Ahmad O. Alokaily, Ahmed A. Aldohbeyb, Mohamed A. Almadi, Fahed K. Alnawfal, Shahad N. Alshamlan, Suhail S. Alshahrani, Khalid Alhussaini, Alaa M. Albishi, Khalid I. Aloraini, Ahmad Zahid Rao, et al.

    Surface electromyography (sEMG) is widely used to assess muscle activity in clinical and research settings. However, while conventional wet electrodes have advanced considerably in recent years, they are often limited by disposability, reduced comfort, and limited reusability. Recent advances in additive manufacturing provide opportunities to fabricate customizable, low-cost dry electrodes using conductive filaments. This study aimed to evaluate the feasibility and signal performance of in-house-fabricated 3D-printed sEMG electrodes made from three commercially available conductive filaments, (Fili, Filaflex, and Proto-Pasta) differing in base polymer and resistivity, and compared their performance with standard wet electrodes. Surface electrodes were placed over the biceps brachii muscle, and EMG signals were recorded during concentric–eccentric elbow flexion under three loading conditions (3, 5, and 7 kg). Signal quality was assessed using EMG amplitude, signal-to-noise ratio (SNR), and background noise. The results showed no significant differences in SNR or background noise between the 3D-printed electrodes and standard wet electrodes. Among the tested materials, Proto-Pasta electrodes produced the highest mean EMG amplitudes, while Filaflex electrodes showed slightly lower background noise, although these differences were not statistically significant. Overall, the findings indicate that in-house-fabricated 3D-printed electrodes can provide signal quality comparable to conventional wet electrodes, supporting their potential use as low-cost and customizable alternatives for sEMG applications in research and wearable monitoring systems.

  • 3D-printed flexible strain FDM sensor for monitoring finger joint movement

    by Ziyad Aloqalaa, Abdulsalam A. Al-Tamimi, Soliman A. Alhudaithy, Faisal S. Fakhouri, Omar Alageel, Abdulaziz S. Fakhouri


  • Open Access

    Automatic Active Contour Algorithm for Detecting Early Brain Tumors in Comparison with AI Detection

    by Mohammed Almijalli, Faten A. Almusayib, Ghala F. Albugami, Ziyad Aloqalaa, Omar Altwijri, Ali S. Saad

    The automatic detection of objects in medical photographs is an essential component of the diagnostic procedure. The issue of early-stage brain tumor detection has progressed significantly with the use of deep learning algorithms (DLA), particularly convolutional neural networks (CNN). The issue lies in the fact that these algorithms necessitate a training phase involving a large database over several hundred images, which can be time-consuming and require complex computational infrastructure. This study aimed to comprehensively evaluate a proposed method, which relies on an active contour algorithm, for identifying and distinguishing brain tumors in magnetic resonance images. We tested the proposed algorithm using 50 brain images, specifically focusing on glioma tumors, while 2000 images were used for DLA from the BRATS Challenges 2021. The proposed segmentation method is made up of an active contour algorithm, an anisotropic diffusion filter for pre-processing, active contour segmentation (Chan-Vese), and morphologic operations for segmentation refinement. We evaluated its performance using various metrics, such as accuracy, precision, sensitivity, specificity, Jaccard index, Dice index, and Hausdorff distance. The proposed method provided an average of the first six performance metrics of 0.96, which is higher than most classical image segmentation methods and was comparable to the deep learning methods, which have an average performance score of 0.98. These results indicate its ability to detect brain tumors accurately and rapidly. The results section provided both numerical and visual insights into the similarity between segmented and ground truth tumor areas. The findings of this study highlighted the potential of computer-based methods in improving brain tumor identification using magnetic resonance imaging. Future work must validate the efficacy of these segmentation approaches across different brain tumor categories and improve computing efficiency to integrate the technology into clinical processes.


  • Open Access

    Novel Deep-Learning Approach for Automatic Diagnosis of Alzheimer’s Disease from MRI

    by Omar Altwijri, Reem Alanazi, Adham Aleid, Khalid Alhussaini, Ziyad Aloqalaa, Mohammed Almijalli, Ali Saad

    This study introduces a novel deep-learning methodology that is customized to automatically diagnose Alzheimer’s disease (AD) through the analysis of MRI datasets. The process of diagnosing AD via the visual examination of magnetic resonance imaging (MRI) presents considerable challenges. The visual diagnosis of mild to very mild stages of AD is challenging due to the MRI similarities observed between a brain that is aging normally and one that has AD. The detection of AD with extreme precision is critical during its early stages. Deep-learning techniques have recently been shown to be significantly more effective than human detection in identifying various stages of AD, enabling early-stage diagnosis. The aim of this research is to develop a deep-learning approach that utilizes pre-trained convolutional neural networks (CNNs) to accurately detect the severity levels of AD, particularly in situations where the quantity and quality of available datasets are limited. In this approach, the AD dataset is preprocessed via a refined image processing module prior to the training phase. The proposed method was compared to two well-known deep-learning algorithms (VGG16 and ResNet50) using four Kaggle AD datasets: one for the normal stage of the disease and three for the mild, very mild, and moderate stages, respectively. This allowed us to evaluate the effectiveness of the classification results. The three models were compared using six performance metrics. The results achieved with our approach indicate an overall detection accuracy of 99.3%, which is superior to the other existing models.


  • Open Access

    3D‐Printed Electrocardiogram Dry Electrodes Using Four Commercially Available Polylactic Acid Conductive Filaments

    by Ziyad M. Aloqalaa

    Cardiovascular diseases (CVDs) are the leading cause of death worldwide. Therefore, the ability to monitor electrocardiogram (ECG) in the long term could save patients’ lives by allowing early diagnosis and intervention. Dry electrodes are the best option to accomplish this task. 3D printing is one of the popular techniques currently used to construct dry electrodes. This project designs, builds, tests, and compares 3D printed ECG electrodes using four commercially available electrically conductive polylactic acid‐based fuzed deposition modeling filaments. Also, this project uses these printed electrodes to acquire ECG raw signals. Then it compares these signals by calculating their signal‐to‐noise ratio (SNR) and their ability to measure heart rate using the Pan–Tompkins algorithm. Also, the resistance of these printed electrodes is measured. In conclusion, all printed electrodes in this experiment show acceptable efficiency with SNR values equal to or larger than 18.89 dB, and these electrodes prove their ability to measure heart rate using the Pan–Tompkins algorithm. However, according to the results of this experiment, one commercially available brand (Proto‐Pasta) is more favorable to use. Proto‐Pasta has the highest SNR value (20.71 dB), the second lower resistance values (∼ from 600Ωto 2 kΩ), the lowest 60 Hz powerline and low‐frequency noise, the most accurate printed electrodes (the printed electrodes have less shape deformity compared to other brands), and no any noticeable physical malfunction (no knops break from the electrodes during the test process).


  • Open Access

    Electrically Conductive Fused Deposition Modeling Filaments: Current Status and Medical Applications

    by Ziyad Aloqalaa

    Fused Deposition Modeling (FDM) is one of the most popular three dimensional (3D) printing techniques especially among researchers. Recently, FDM has been widely developed and improved in many areas. One of these improvements is the introduction of electrically conductive filaments. In general, conductive filaments are usually made of conductive polymer composites. These composites consist of a thermoplastic material blended with carbon-based materials. The quantity of commercially available conductive filaments has grown significantly in recent years. This paper presents a sample of currently available conductive filaments (eight filaments were chosen). These samples were compared by measuring resistance value and highlighting resulted defects of each sample. Additionally, this paper searched and reviewed articles that used conductive FDM filaments in medical applications. These articles were collected and summarized in terms of name of filaments were used, the specific function of the printed conductive object, and name of the printer used to print the conductive object. In conclusion, the main purpose of this project is to facilitate the work of future medical researchers who would like to use commercially available conductive FDM filaments.


  • Open Access

    3d Printed Bio-potential Dry Electrodes

    by Ziyad Aloqalaa

    The most commonly used bio-potential electrodes are silver/silver chlorides gel-electrodes (Ag/AgCl electrodes). However, wet electrodes are not suited for daily usage and long-term monitoring. Dry electrodes are the best choice for long-term measurements. Dry electrodes can be fabricated using various methods and materials; one of these methods is three dimensional (3d) printing. 3d printing is a cost-effective method and can be easily used in mass production. This paper will present 3d printed bio-potential dry electrodes using five different commercially available fused deposition modeling (FDM) electrically conductive filaments. Then, these printed electrodes will be tested and validated using electrocardiogram (ECG) portable acquisition system. Three out of five filaments were printed successfully. Collected ECG data from these electrodes showed acceptable quality with Signal to Noise Ratios (SNRs) ranging around 20 dB when compared with wet electrodes collected raw data as a reference. In conclusion, this study designed and printed a 100% 3d printed electrodes from three different FDM filaments which could be used efficiently for ECG signal monitoring in resting position.