SGStefanie Gürzing

Stefanie Gürzing

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Stefanie Gürzing has a total of 12 co-authors. Here are the top co-authors by number of shared publications:

  • Anja L. Thiebes

    Department of Biohybrid and Medical Textiles (BioTex), AME—Institute of Applied Medical Engineering, Helmholtz Institute Aachen, RWTH Aachen University, Aachen, Germany

    1 shared publication
  • Anja Lena Thiebes

    Department of Biohybrid & Medical Textiles, Institute of Applied Medical Engineering, Helmholtz Institute, RWTH Aachen University, Germany

    1 shared publication
  • Christian G. Cornelissen

    Department of Biohybrid and Medical Textiles (BioTex), AME—Institute of Applied Medical Engineering, Helmholtz Institute Aachen, RWTH Aachen University, Aachen, Germany

    1 shared publication
  • Christian Gabriel Cornelissen

    Pulmonology and Medical Intensive Care, University Hospital Aachen / O11 biomedical GmbH, Aachen, Germany

    1 shared publication
  • Georg H. Möller

    Institute of Heat and Mass Transfer (WSA), RWTH Aachen University, Augustinerbach 6, 52056 Aachen, Germany

    1 shared publication
  • Jonas Zingsheim

    Department of Biohybrid & Medical Textiles (BioTex), AME—Institute of Applied Medical Engineering, Helmholtz Institute Aachen, RWTH Aachen University, Forckenbeckstraße 55, 52074 Aachen, Germany

    1 shared publication

Latest Publications

  • Open Access

    Effervescent Atomizer as Novel Cell Spray Technology to Decrease the Gas-to-Liquid Ratio

    by Anja Lena Thiebes, Sarah Klein, Jonas Zingsheim, Georg H. Möller, Stefanie Gürzing, Manuel A. Reddemann, Mehdi Behbahani, Stefan Jockenhoevel, Christian G. Cornelissen

    Cell spraying has become a feasible application method for cell therapy and tissue engineering approaches. Different devices have been used with varying success. Often, twin-fluid atomizers are used, which require a high gas velocity for optimal aerosolization characteristics. To decrease the amount and velocity of required air, a custom-made atomizer was designed based on the effervescent principle. Different designs were evaluated regarding spray characteristics and their influence on human adipose-derived mesenchymal stromal cells. The arithmetic mean diameters of the droplets were 15.4–33.5 µm with decreasing diameters for increasing gas-to-liquid ratios. The survival rate was >90% of the control for the lowest gas-to-liquid ratio. For higher ratios, cell survival decreased to approximately 50%. Further experiments were performed with the design, which had shown the highest survival rates. After seven days, no significant differences in metabolic activity were observed. The apoptosis rates were not influenced by aerosolization, while high gas-to-liquid ratios caused increased necrosis levels. Tri-lineage differentiation potential into adipocytes, chondrocytes, and osteoblasts was not negatively influenced by aerosolization. Thus, the effervescent aerosolization principle was proven suitable for cell applications requiring reduced amounts of supplied air. This is the first time an effervescent atomizer was used for cell processing.


  • Suitability of Bronchoscopic Spraying for Fluid Deposition in Lower Airway Regions: Fluorescence Analysis on a Transparent In Vitro Airway Model

    by Stefanie Gürzing, Anja L. Thiebes, Christian G. Cornelissen, Stefan Jockenhoevel, Manuel A. Reddemann

    Introduction: Bronchoscopic spraying has potential for the application of therapeutic drugs in distal regions of the lung by bypassing the upper airways. However, there is a lack of understanding about the underlying fluid transport phenomena that are responsible for the intrapulmonary propagation of applied liquid. Methods: By using a transparent airway model, this study provides first experimental insights into relevant transport phenomena of bronchoscopic spraying. Furthermore, the penetration depth of the application is quantitatively evaluated. Laser-induced fluorescence is used to analyze fluid propagation in the transparent channels. Potential influencing factors such as the positioning in different airways, application number, breathing pattern, and lung obstructions are varied within this study to determine their influence on liquid deposition. Findings: This study shows that the method of bronchoscopic spraying allows the application of liquid in distal regions of the airway model. The position of the bronchoscope is a key influencing factor in increasing the penetration depth. We found that fluid transport along the distal airways essentially occurs by the film and plug flow phenomenon during application, which is similar to the transport mechanisms during instillation. Liquid plugs in lower airways are responsible for the reorganization of liquid during proximal movements and thereby influence the penetration depth in subsequent applications.