David Scott Coburn
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
David Scott Coburn has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Evgeny Nazaretski
National Synchrotron Light Source II, Brookhaven National Laboratory, Upton, NY 11973, USA
2 shared publications - Weihe Xu
National Synchrotron Light Source II, Brookhaven National Laboratory, Upton, NY 11973, USA
2 shared publications - Akhil Tayal
National Synchrotron Light Source II Brookhaven National Laboratory, Upton New York USA
1 shared publication - Andrew M. Kiss
Stanford Synchrotron Radiation Lightsource, SLAC National Accelerator Laboratory, Menlo Park, CA 94025, USA
1 shared publication - Denis Leshchev
National Synchrotron Light Source II, Brookhaven National Laboratory, Upton, NY 11973, USA
1 shared publication - Dominik Wierzbicki
National Synchrotron Light Source II Brookhaven National Laboratory Upton New York USA
1 shared publication
Latest Publications
- Open Access
- 30 October 2024
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 31 (6) , 1609-1621
Five-analyzer Johann spectrometer for hard X-ray photon-in/photon-out spectroscopy at the Inner Shell Spectroscopy beamline at NSLS-II: design, alignment and data acquisition
Here, a recently commissioned five-analyzer Johann spectrometer at the Inner Shell Spectroscopy beamline (8-ID) at the National Synchrotron Light Source II (NSLS-II) is presented. Designed for hard X-ray photon-in/photon-out spectroscopy, the spectrometer achieves a resolution in the 0.5–2 eV range, depending on the element and/or emission line, providing detailed insights into the local electronic and geometric structure of materials. It serves a diverse user community, including fields such as physical, chemical, biological, environmental and materials sciences. This article details the mechanical design, alignment procedures and data-acquisition scheme of the spectrometer, with a particular focus on the continuous asynchronous data-acquisition approach that significantly enhances experimental efficiency.
- 30 October 2024
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 31 (6) , 1609-1621
Open AccessFive-analyzer Johann spectrometer for hard X-ray photon-in/photon-out spectroscopy at the Inner Shell Spectroscopy beamline at NSLS-II: design, alignment and data acquisition
Here, a recently commissioned five-analyzer Johann spectrometer at the Inner Shell Spectroscopy beamline (8-ID) at the National Synchrotron Light Source II (NSLS-II) is presented. Designed for hard X-ray photon-in/photon-out spectroscopy, the spectrometer achieves a resolution in the 0.5–2 eV range, depending on the element and/or emission line, providing detailed insights into the local electronic and geometric structure of materials. It serves a diverse user community, including fields such as physical, chemical, biological, environmental and materials sciences. This article details the mechanical design, alignment procedures and data-acquisition scheme of the spectrometer, with a particular focus on the continuous asynchronous data-acquisition approach that significantly enhances experimental efficiency.
- Open Access
- 29 July 2022
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 29 (5) , 1284-1291
A new Kirkpatrick–Baez-based scanning microscope for the Submicron Resolution X-ray Spectroscopy (SRX) beamline at NSLS-II
The development, construction, and first commissioning results of a new scanning microscope installed at the 5-ID Submicron Resolution X-ray Spectroscopy (SRX) beamline at NSLS-II are reported. The developed system utilizes Kirkpatrick–Baez mirrors for X-ray focusing. The instrument is designed to enable spectromicroscopy measurements in 2D and 3D with sub-200 nm spatial resolution. The present paper focuses on the design aspects, optical considerations, and specifics of the sample scanning stage, summarizing some of the initial commissioning results.
- 29 July 2022
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 29 (5) , 1284-1291
Open AccessA new Kirkpatrick–Baez-based scanning microscope for the Submicron Resolution X-ray Spectroscopy (SRX) beamline at NSLS-II
The development, construction, and first commissioning results of a new scanning microscope installed at the 5-ID Submicron Resolution X-ray Spectroscopy (SRX) beamline at NSLS-II are reported. The developed system utilizes Kirkpatrick–Baez mirrors for X-ray focusing. The instrument is designed to enable spectromicroscopy measurements in 2D and 3D with sub-200 nm spatial resolution. The present paper focuses on the design aspects, optical considerations, and specifics of the sample scanning stage, summarizing some of the initial commissioning results.