Mohamed Ouameur
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Mohamed Ouameur has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
- Francois Ziade
Laboratoire National de Mtrologie et dEssais, Trappes, France
6 shared publications Yann Le Bihan
GeePs, Laboratoire Génie Electrique et Electronique de Paris, Gif-sur-Yvette, France
4 shared publicationsFrancois Ziade
Laboratoire National de Metrologie et d'Essais, 29avenue Roger Hennequin, Trappes, 78197, France
3 shared publicationsMohamed Agazar
Electrical Metrology Division, Laboratoire National de Mtrologie et dEssais,Paris,France
3 shared publications- Mohamed Agazar
Laboratoire National de Métrologie et d’Essais (LNE), 1 Rue Gaston Boissier, 75015 Paris, France
3 shared publications Borut Pinter
Slovenian Institute of Quality and Metrology, Ljubljana, Slovenia
2 shared publications
Latest Publications
- Open Access
The Design and Development of a Low-Cost and Environmentally Friendly Voltage Divider for On-Site High-Voltage Calibration up to 850 kV
This paper presents the design, development, and characterization of a low-cost and environmentally friendly high-voltage divider optimized for on-site calibration up to 850 kV. Unlike traditional dividers that rely on oil or SF6 for insulation, both of which pose environmental risk and regulation issues, the proposed system uses modular construction with commercial off-the-shelf components and natural air insulation, minimizing environmental impact and facilitating transport, calibration, and maintenance. Despite using air insulation, the divider demonstrates excellent uncertainty performance. Characterization results show frequency linearity better than 0.2% up to 100 kHz and a bandwidth exceeding 10 MHz, making it suitable for the measurement of a wide range of voltage types. Static and dynamic performance evaluations confirm reliable scale factor stability and low measurement uncertainty: 0.01% for DC (550 kV), 0.3% for AC (405 kV), and 0.7% for impulses such as 1.2/50 µs (850 kV). The system offers a practical and sustainable solution for high-voltage measurements, meeting growing industrial and European environmental demands.
Open AccessThe Design and Development of a Low-Cost and Environmentally Friendly Voltage Divider for On-Site High-Voltage Calibration up to 850 kV
This paper presents the design, development, and characterization of a low-cost and environmentally friendly high-voltage divider optimized for on-site calibration up to 850 kV. Unlike traditional dividers that rely on oil or SF6 for insulation, both of which pose environmental risk and regulation issues, the proposed system uses modular construction with commercial off-the-shelf components and natural air insulation, minimizing environmental impact and facilitating transport, calibration, and maintenance. Despite using air insulation, the divider demonstrates excellent uncertainty performance. Characterization results show frequency linearity better than 0.2% up to 100 kHz and a bandwidth exceeding 10 MHz, making it suitable for the measurement of a wide range of voltage types. Static and dynamic performance evaluations confirm reliable scale factor stability and low measurement uncertainty: 0.01% for DC (550 kV), 0.3% for AC (405 kV), and 0.7% for impulses such as 1.2/50 µs (850 kV). The system offers a practical and sustainable solution for high-voltage measurements, meeting growing industrial and European environmental demands.
- Open Access
Calibration of Inductance Using a PXI-Based Maxwell–Wien Bridge from 20 Hz to 20 kHz
This paper presents a Maxwell–Wien bridge for use in the calibration of standard inductances with values between 100 µH and 10 H and frequencies from 20 Hz to 20 kHz. The inductances are measured by comparison with a variable standard capacitor, in parallel association with a variable standard resistor, on the bridge modified by a Wagner balance. The variable standards are calibrated after the bridge balance. The other resistors in the bridge are standard resistors, pre-calibrated in AC using an automatic Wheatstone bridge and in DC after the bridge has been balanced using a comparison bridge with standard resistors traceable to the quantum Hall effect standards. PXI modules are used to supply the bridge with two voltages controllable in amplitude and phase. Design details and the uncertainty budget are discussed. For an inductance of 100 mH characterized by an internal resistance of 83 Ω, the expanded uncertainties are less than 6 µH on the inductance and 20 mΩ on the internal resistance. For inductances from 100 µH to 10 H, the relative uncertainties are less than 0.02% of the inductance and 0.2% of the internal resistance from 20 Hz to 20 kHz.
Open AccessCalibration of Inductance Using a PXI-Based Maxwell–Wien Bridge from 20 Hz to 20 kHz
This paper presents a Maxwell–Wien bridge for use in the calibration of standard inductances with values between 100 µH and 10 H and frequencies from 20 Hz to 20 kHz. The inductances are measured by comparison with a variable standard capacitor, in parallel association with a variable standard resistor, on the bridge modified by a Wagner balance. The variable standards are calibrated after the bridge balance. The other resistors in the bridge are standard resistors, pre-calibrated in AC using an automatic Wheatstone bridge and in DC after the bridge has been balanced using a comparison bridge with standard resistors traceable to the quantum Hall effect standards. PXI modules are used to supply the bridge with two voltages controllable in amplitude and phase. Design details and the uncertainty budget are discussed. For an inductance of 100 mH characterized by an internal resistance of 83 Ω, the expanded uncertainties are less than 6 µH on the inductance and 20 mΩ on the internal resistance. For inductances from 100 µH to 10 H, the relative uncertainties are less than 0.02% of the inductance and 0.2% of the internal resistance from 20 Hz to 20 kHz.
- Open Access
Wideband Current Transducer Traceable Calibration up to 10 A and 1 MHz
Energy efficiency is an important issue in industry, especially with the ever-increasing consumption of electrical energy. The power quality and the traceability of metering devices are essential when integrating energy metering systems for energy efficiency. This management requires an understanding of electrical current events such as pulse and transient currents. Current transducers are widely used to measure these electrical current events up to a few megahertz. Their use makes it possible to measure not only the main current flowing through the transducer, but also the bypass current that affects electrical equipment. Calibration of these sensors up to a few megahertz then becomes an essential step. Currently, most calibration methods are limited to 100 kHz frequency for a current of 10 A. This paper presents an improvement of a traceable calibration methodology for current transducers up to 10 A and 1 MHz, thus increasing, by 10 times, the current level for such high frequency applications. This calibration methodology is based on a metrological traceability chain (uninterrupted link to the International System of Units) with respect to a calculable current shunt and is currently the only traceable method for calibrating current transducers at 10 A and up to 1 MHz. The uncertainty obtained for the transimpedance ratio is less than 0.2%, which is considerably reduced with respect to the existing capabilities.
Open AccessWideband Current Transducer Traceable Calibration up to 10 A and 1 MHz
Energy efficiency is an important issue in industry, especially with the ever-increasing consumption of electrical energy. The power quality and the traceability of metering devices are essential when integrating energy metering systems for energy efficiency. This management requires an understanding of electrical current events such as pulse and transient currents. Current transducers are widely used to measure these electrical current events up to a few megahertz. Their use makes it possible to measure not only the main current flowing through the transducer, but also the bypass current that affects electrical equipment. Calibration of these sensors up to a few megahertz then becomes an essential step. Currently, most calibration methods are limited to 100 kHz frequency for a current of 10 A. This paper presents an improvement of a traceable calibration methodology for current transducers up to 10 A and 1 MHz, thus increasing, by 10 times, the current level for such high frequency applications. This calibration methodology is based on a metrological traceability chain (uninterrupted link to the International System of Units) with respect to a calculable current shunt and is currently the only traceable method for calibrating current transducers at 10 A and up to 1 MHz. The uncertainty obtained for the transimpedance ratio is less than 0.2%, which is considerably reduced with respect to the existing capabilities.
- Open Access
Digital Impedance Bridge for Four-Terminal-Pair AC Resistor Calibration up to 20 kHz
For this study, a substitution principle-based impedance bridge has been developed to calibrate AC resistors in a four-terminal-pair (4TP) configuration. The calibration is performed in the full complex plane for resistances ranging from 100 mΩ to 400 Ω and frequencies of between 50 Hz and 20 kHz. The automated bridge is based on four resistors associated with two high-impedance stages. The balancing of the bridge is achieved by means of PXI modules. The bridge is automatically balanced via a simplex top-down algorithm. The new bridge is primarily used for the measurement chain of AC standard resistors defined in a 4TP configuration at LNE, which are used for routine customer calibrations. The traceability of LNE’s standard resistors when defined in a 4TP configuration is ensured by a measurement chain from a 1 kΩ reference resistor using the new bridge. The reference resistor was calibrated previously via comparison with a calculable resistor up to 20 kHz. The bridge was validated via comparison with calibration results obtained in 1983 and 2009. For a resistor of 1 Ω at 1 kHz, the uncertainty of the series resistance variation and the phase shift are less than 6 µΩ/Ω (k = 1) and 6 µrad (k = 1), respectively.
Open AccessDigital Impedance Bridge for Four-Terminal-Pair AC Resistor Calibration up to 20 kHz
For this study, a substitution principle-based impedance bridge has been developed to calibrate AC resistors in a four-terminal-pair (4TP) configuration. The calibration is performed in the full complex plane for resistances ranging from 100 mΩ to 400 Ω and frequencies of between 50 Hz and 20 kHz. The automated bridge is based on four resistors associated with two high-impedance stages. The balancing of the bridge is achieved by means of PXI modules. The bridge is automatically balanced via a simplex top-down algorithm. The new bridge is primarily used for the measurement chain of AC standard resistors defined in a 4TP configuration at LNE, which are used for routine customer calibrations. The traceability of LNE’s standard resistors when defined in a 4TP configuration is ensured by a measurement chain from a 1 kΩ reference resistor using the new bridge. The reference resistor was calibrated previously via comparison with a calculable resistor up to 20 kHz. The bridge was validated via comparison with calibration results obtained in 1983 and 2009. For a resistor of 1 Ω at 1 kHz, the uncertainty of the series resistance variation and the phase shift are less than 6 µΩ/Ω (k = 1) and 6 µrad (k = 1), respectively.
- 14 September 2022
- Published by IOP Publishing in Metrologia
- Vol. 59 (5) , 055005
New impedance bridge at LNE for the two terminal-pair AC resistor calibration up to 20 kHz
This paper presents the evolution of LNE’s impedance bridge (Wheatstone bridge) used to calibrate AC resistors defined in the two terminal-pair configuration. A new automated Wheatstone bridge, based on four resistances, was developed to operate in the full complex plane for resistances ranging from 400 Ω to 2 MΩ and for frequencies up to 20 kHz. A commercial dual precision arbitrary waveform generator supplies the bridge and PXI modules achieve the balance. Phase and frequency synchronization solutions between the arbitrary waveform generator source and the PXI modules were used. The choice of these instruments allows the bridge to be easily automated and to benefit from recent progress in the development of digital-analog converters, in particular those with high frequency sampling rates and resolution. The bridge is mainly dedicated to realize the periodic calibration of LNE’s standard resistors, used for routine customer calibrations. The traceability of LNE’s standard resistors is ensured, firstly, by the calibration of a 1 kΩ resistor by comparison to a calculable resistor up to 20 kHz. Then, this resistor is used as a reference element to ensure the traceability of all LNE’s standard resistors using the new bridge. The validation was done by comparing the results obtained, for some resistors with very low drift, with those obtained during calibrations performed in 1983, 1995 and 2009. For resistors of 1 kΩ in a 1:1 ratio, the expanded uncertainty of series resistance variation and argument are, respectively, less than 1.3 µΩ Ω−1 (k = 1) and 1.2 µrad (k = 1), up to 20 kHz.
- 14 September 2022
- Published by IOP Publishing in Metrologia
- Vol. 59 (5) , 055005
New impedance bridge at LNE for the two terminal-pair AC resistor calibration up to 20 kHz
This paper presents the evolution of LNE’s impedance bridge (Wheatstone bridge) used to calibrate AC resistors defined in the two terminal-pair configuration. A new automated Wheatstone bridge, based on four resistances, was developed to operate in the full complex plane for resistances ranging from 400 Ω to 2 MΩ and for frequencies up to 20 kHz. A commercial dual precision arbitrary waveform generator supplies the bridge and PXI modules achieve the balance. Phase and frequency synchronization solutions between the arbitrary waveform generator source and the PXI modules were used. The choice of these instruments allows the bridge to be easily automated and to benefit from recent progress in the development of digital-analog converters, in particular those with high frequency sampling rates and resolution. The bridge is mainly dedicated to realize the periodic calibration of LNE’s standard resistors, used for routine customer calibrations. The traceability of LNE’s standard resistors is ensured, firstly, by the calibration of a 1 kΩ resistor by comparison to a calculable resistor up to 20 kHz. Then, this resistor is used as a reference element to ensure the traceability of all LNE’s standard resistors using the new bridge. The validation was done by comparing the results obtained, for some resistors with very low drift, with those obtained during calibrations performed in 1983, 1995 and 2009. For resistors of 1 kΩ in a 1:1 ratio, the expanded uncertainty of series resistance variation and argument are, respectively, less than 1.3 µΩ Ω−1 (k = 1) and 1.2 µrad (k = 1), up to 20 kHz.
- 29 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-10
Measurements of AC Resistances up to 10 MHz Using a VNA and Calculable Adapters
Resistors are widely used in industry for several applications, for example power measurements and electrical transient measurements. However, it is necessary to evaluate the amplitude and phase of the resistor impedance according to the frequency before their use. The existing low frequency methods used to calibrate resistors are limited to 1 MHz. A high frequency approach is proposed to characterize resistors up to a few MHz with traceable measurements. This method is based on a vector network analyzer (VNA). Type-N or BNC cables can be used to perform traceable measurements in the megahertz frequency range. However, several electrical resistors used in industry or in metrology laboratories are equipped with other types of connectors (such as UHF or BNC) that require adapters to establish the electrical connection with the VNA. In this article, an example of resistors with UHF connectors is presented to illustrate this case. Calculable RF adapters for UHF to Type-N connectors are developed to cancel the impact of these adapters on impedance measurements. The proposed method can be adapted for other type of connectors. Hence, the frequency response of resistors can be obtained in the megahertz frequency range. While the uncertainties are typically higher than those obtained with low frequency methods, the method presented in this paper is to our knowledge, the only one capable of simultaneously measuring the amplitude and phase of resistor impedance up to a few megahertz with acceptable uncertainties and traceability established to the International System of Units (SI).
- 29 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-10
Measurements of AC Resistances up to 10 MHz Using a VNA and Calculable Adapters
Resistors are widely used in industry for several applications, for example power measurements and electrical transient measurements. However, it is necessary to evaluate the amplitude and phase of the resistor impedance according to the frequency before their use. The existing low frequency methods used to calibrate resistors are limited to 1 MHz. A high frequency approach is proposed to characterize resistors up to a few MHz with traceable measurements. This method is based on a vector network analyzer (VNA). Type-N or BNC cables can be used to perform traceable measurements in the megahertz frequency range. However, several electrical resistors used in industry or in metrology laboratories are equipped with other types of connectors (such as UHF or BNC) that require adapters to establish the electrical connection with the VNA. In this article, an example of resistors with UHF connectors is presented to illustrate this case. Calculable RF adapters for UHF to Type-N connectors are developed to cancel the impact of these adapters on impedance measurements. The proposed method can be adapted for other type of connectors. Hence, the frequency response of resistors can be obtained in the megahertz frequency range. While the uncertainties are typically higher than those obtained with low frequency methods, the method presented in this paper is to our knowledge, the only one capable of simultaneously measuring the amplitude and phase of resistor impedance up to a few megahertz with acceptable uncertainties and traceability established to the International System of Units (SI).
- 27 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 0796-0798
A Double Precision Arbitrary Waveform Generator Based Calibration System for Low-Value AC Resistors up to 20 kHz
In this paper we present an automated impedance bridge based on a commercial double-precision arbitrary waveform generator. The automated bridge was developed to compare impedance standards of arbitrary ratios in a full complex plane from 1 mΩ to 100Ω at frequency ranges up to 20 kHz. The expanded uncertainty of the ac-dc difference and phase angle are, respectively, less than 130 µΩ/Ω and 126 µrad up to 20 kHz for impedance ratio 1:1. The results of experimental measurements are compared with a existing system based on a sampling approach, used to calibrate AC resistors up to 20 kHz, with the objective of validate the new experimental setup and its automation.
- 27 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 0796-0798
A Double Precision Arbitrary Waveform Generator Based Calibration System for Low-Value AC Resistors up to 20 kHz
In this paper we present an automated impedance bridge based on a commercial double-precision arbitrary waveform generator. The automated bridge was developed to compare impedance standards of arbitrary ratios in a full complex plane from 1 mΩ to 100Ω at frequency ranges up to 20 kHz. The expanded uncertainty of the ac-dc difference and phase angle are, respectively, less than 130 µΩ/Ω and 126 µrad up to 20 kHz for impedance ratio 1:1. The results of experimental measurements are compared with a existing system based on a sampling approach, used to calibrate AC resistors up to 20 kHz, with the objective of validate the new experimental setup and its automation.
- 23 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 257-260
A PXI Modules-Based Voltage Injection System for AC Resistors Calibration
Wheatstone bridges are frequently used to calibrate AC resistors. The balance of the AC Whetstone Bridge can be ensured by injecting an in-phase and quadrature voltage as a function of the input voltage of the bridge. PXI modules are usually used as voltage injection systems (phase and quadrature), especially for automated bridges. In this paper, a comparison is presented between different high-performance PXI modules, where these devices are used as voltage injection systems for AC resistor calibration. Here three PXI modules are compared: Applicos-AWG22, EMX-1434, and NI-4461, with experimental measurements performed up to 20 kHz on these modules. The results are presented with several comparisons to get an insight into the performances of the generators that are suitable for voltage injection systems, as well as, for calibration of AC resistors. The results are then validated by using these PXI modules in a Wheatstone bridge used at LNE to calibrate AC resistors.
- 23 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 257-260
A PXI Modules-Based Voltage Injection System for AC Resistors Calibration
Wheatstone bridges are frequently used to calibrate AC resistors. The balance of the AC Whetstone Bridge can be ensured by injecting an in-phase and quadrature voltage as a function of the input voltage of the bridge. PXI modules are usually used as voltage injection systems (phase and quadrature), especially for automated bridges. In this paper, a comparison is presented between different high-performance PXI modules, where these devices are used as voltage injection systems for AC resistor calibration. Here three PXI modules are compared: Applicos-AWG22, EMX-1434, and NI-4461, with experimental measurements performed up to 20 kHz on these modules. The results are presented with several comparisons to get an insight into the performances of the generators that are suitable for voltage injection systems, as well as, for calibration of AC resistors. The results are then validated by using these PXI modules in a Wheatstone bridge used at LNE to calibrate AC resistors.
- 1 August 2021
- Published by Avestia Publishing
Design of Low Impedance Standard Defined In a Four-Terminal-Pair Configuration
- 1 August 2021
- Published by Avestia Publishing
Design of Low Impedance Standard Defined In a Four-Terminal-Pair Configuration