Joshua Bierbrier
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Joshua Bierbrier has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Donald Louis Collins
McConnell Brain Imaging Centre, Montreal Neurological Institute, McGill University
2 shared publications Daniel A. Di Giovanni
Department of Neurology and Neurosurgery, McGill University, Montreal, QC, Canada
1 shared publication- David J. A. Plemel
Univ Alberta, Dept Ophthalmol & Visual Sci, Edmonton, AB, Canada
1 shared publication - Davin Johnson
Department of Ophthalmology, Queen's University, Kingston, ON, Canada
1 shared publication Houssem-Eddine Gueziri
McConnell Brain Imaging Center, Montreal Neurological Institute and Hospital, Montreal, QC, Canada
1 shared publication- Lauren Breslin1 shared publication
Latest Publications
- Open Access
- 5 November 2026
- Published by Elsevier in Canadian Journal of Ophthalmology
Spontaneous expulsive suprachoroidal hemorrhage: case series, taxonomy, and systematic review
- 5 November 2026
- Published by Elsevier in Canadian Journal of Ophthalmology
Open AccessSpontaneous expulsive suprachoroidal hemorrhage: case series, taxonomy, and systematic review
- Open Access
- 6 June 2025
- Published by Elsevier in Canadian Journal of Ophthalmology
- Vol. 60 (5) , 267-271
Comparing the rate of cataract surgery complications between a hospital and an independent health facility
- 6 June 2025
- Published by Elsevier in Canadian Journal of Ophthalmology
- Vol. 60 (5) , 267-271
Open AccessComparing the rate of cataract surgery complications between a hospital and an independent health facility
- 23 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 70 (9) , 999-1015
Toward Estimating MRI-Ultrasound Registration Error in Image-Guided Neurosurgery
Image-guided neurosurgery allows surgeons to view their tools in relation to pre-operatively acquired patient images and models. To continue using neuronavigation systems throughout operations, image registration between pre-operative images (typically MRI) and intra-operative images (e.g., ultrasound) are common to account for brain shift (deformations of the brain during surgery). We implemented a method to estimate MRI-ultrasound registration errors, with the goal of enabling surgeons to quantitatively assess the performance of linear or nonlinear registrations. To the best of our knowledge, this is the first dense error estimating algorithm applied to multimodal image registrations. The algorithm is based on a previously proposed sliding-window convolutional neural network that operates on a voxel-wise basis. To create training data where the true registration error is known, simulated ultrasound images were created from pre-operative MRI images and artificially deformed. The model was evaluated on artificially deformed simulated ultrasound data as well as real ultrasound data with manually annotated landmark points. The model achieved a mean absolute error of 0.977 ± 0.988 mm and correlation of 0.8 ± 0.062 on the simulated ultrasound data, and a mean absolute error of 2.24 ± 1.89 mm and a correlation of 0.246 on the real ultrasound data. We discuss concrete areas to improve the results on real ultrasound data. Our progress lays the foundation for future developments and ultimately implementation on clinical neuronavigation systems.
- 23 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 70 (9) , 999-1015
Toward Estimating MRI-Ultrasound Registration Error in Image-Guided Neurosurgery
Image-guided neurosurgery allows surgeons to view their tools in relation to pre-operatively acquired patient images and models. To continue using neuronavigation systems throughout operations, image registration between pre-operative images (typically MRI) and intra-operative images (e.g., ultrasound) are common to account for brain shift (deformations of the brain during surgery). We implemented a method to estimate MRI-ultrasound registration errors, with the goal of enabling surgeons to quantitatively assess the performance of linear or nonlinear registrations. To the best of our knowledge, this is the first dense error estimating algorithm applied to multimodal image registrations. The algorithm is based on a previously proposed sliding-window convolutional neural network that operates on a voxel-wise basis. To create training data where the true registration error is known, simulated ultrasound images were created from pre-operative MRI images and artificially deformed. The model was evaluated on artificially deformed simulated ultrasound data as well as real ultrasound data with manually annotated landmark points. The model achieved a mean absolute error of 0.977 ± 0.988 mm and correlation of 0.8 ± 0.062 on the simulated ultrasound data, and a mean absolute error of 2.24 ± 1.89 mm and a correlation of 0.246 on the real ultrasound data. We discuss concrete areas to improve the results on real ultrasound data. Our progress lays the foundation for future developments and ultimately implementation on clinical neuronavigation systems.
- 6 July 2022
- Published by Elsevier in Medical Image Analysis
- Vol. 81, 102531
Estimating medical image registration error and confidence: A taxonomy and scoping review
- 6 July 2022
- Published by Elsevier in Medical Image Analysis
- Vol. 81, 102531
Estimating medical image registration error and confidence: A taxonomy and scoping review