Anwar Anwar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Anwar Anwar has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
Achmad Basuki
3 shared publicationsRiyanto Sigit
3 shared publicationsI Putu Adi Surya Gunawan
Politeknik Elektronika Negeri Surabaya
2 shared publications- Arya Brahmanta
Department of Orthodontics, Faculty of Dentistry, Universitas Hang Tuah, Surabaya, Indonesia
1 shared publication - Aulia Dwi Maharani
Universitas Hang Tuah Surabaya
1 shared publication - Bima Sena Bayu Dewantara
Politeknik Elektronika Negeri Surabaya
1 shared publication
Latest Publications
- Open Access
- 31 July 2022
- Published by Universitas Padjadjaran in Padjadjaran Journal of Dentistry
- Vol. 34 (2) , 115-120
Usability testing of “smart odontogram” application based on user’s experience
Introduction: Collecting dental data for odontogram in medical records is done chiefly conventionally and causes a lot of human errors. Disadvantages of the conventional method can be overcome by developing a server-based system to store medical information equipped with embedded artificial intelligence (AI), which can identify the patient’s dental condition using an intra-oral camera with the help of Deep Learning algorithms. It is essential to evaluate the usability of this application to adapt to user needs. This study aimed to know the user’s experience in using this application and also provide information for improvements of the application. Methods: This is quantitative descriptive research with 15 users (dentists) as the respondent. The questionnaire was used to measure the user’s experience using this application. The user’s experiences measured are effectivity, efficiency, and satisfaction. Results: The highest scores of respondents on the three variables are extremely efficient, effective, and satisfied (9 people). The lowest score is slightly efficient and neutral on the efficiency and effectiveness variables (0 people). In the satisfaction variable, the lowest score is slightly satisfied (0 people). Conclusions: The Usability Testing of the “Smart Odontogram” Application based on User’s Experience showed a good result in 3 variables: effectiveness, efficiency, and satisfaction Keywords: smart Odontogram; medical record; application; usability testing; user’s experience
- 31 July 2022
- Published by Universitas Padjadjaran in Padjadjaran Journal of Dentistry
- Vol. 34 (2) , 115-120
Open AccessUsability testing of “smart odontogram” application based on user’s experience
Introduction: Collecting dental data for odontogram in medical records is done chiefly conventionally and causes a lot of human errors. Disadvantages of the conventional method can be overcome by developing a server-based system to store medical information equipped with embedded artificial intelligence (AI), which can identify the patient’s dental condition using an intra-oral camera with the help of Deep Learning algorithms. It is essential to evaluate the usability of this application to adapt to user needs. This study aimed to know the user’s experience in using this application and also provide information for improvements of the application. Methods: This is quantitative descriptive research with 15 users (dentists) as the respondent. The questionnaire was used to measure the user’s experience using this application. The user’s experiences measured are effectivity, efficiency, and satisfaction. Results: The highest scores of respondents on the three variables are extremely efficient, effective, and satisfied (9 people). The lowest score is slightly efficient and neutral on the efficiency and effectiveness variables (0 people). In the satisfaction variable, the lowest score is slightly satisfied (0 people). Conclusions: The Usability Testing of the “Smart Odontogram” Application based on User’s Experience showed a good result in 3 variables: effectiveness, efficiency, and satisfaction Keywords: smart Odontogram; medical record; application; usability testing; user’s experience
- Open Access
- 1 June 2020
- Published by Insight Society in International Journal on Advanced Science, Engineering and Information Technology
- Vol. 10 (3) , 964-973
A New Feature Extraction Method for Classifying Heart Wall from Left Ventricle Cavity
Echocardiography is a method of examination with high-frequency sound waves to obtain images of heart organs. Examination of heart health conditions with echocardiography as an imaging method, serves to detect the potential for heart disease, thus that the right treatment from the evaluation results can be decided. Examination of the source of heart disease with echocardiography was performed using several views, namely the long axis, short axis, two-chamber, and four-chamber. However, the assessment of cardiac function is still carried out conventionally. Thus it is necessary to build a system that can assess cardiac function. This study proposes a feature extraction method for the classification of heart disease based on the left ventricular motion on the short-axis. In this method, feature extraction uses 24 good features for the process of tracking the movement of the left ventricle with optical flow. Each good feature produces four features, namely direction (negative direction and positive direction) and distance (negative distance and positive distance) from the results of left ventricular tracking and produces 96 attributes for the whole process. The features that have been obtained are then processed using several classification algorithms with validation techniques that are, k-folds, and leave one out. The result is a classification algorithm with a gradient boosting classifier method that has the best accuracy. Gradient boosting classifier produces accuracy values with validation techniques for k-folds 90.98%, and leave one out 93.23%. This shows that the gradient boosting classifier can be relied upon for the classification of heart disease using the proposed feature extraction method. In this study, we developed a new feature extraction method from the results of tracking the heart wall using optical flow. This algorithm can produce feature values from the tracking results that can be used to build a knowledge system for the classification of heart health conditions.
- 1 June 2020
- Published by Insight Society in International Journal on Advanced Science, Engineering and Information Technology
- Vol. 10 (3) , 964-973
Open AccessA New Feature Extraction Method for Classifying Heart Wall from Left Ventricle Cavity
Echocardiography is a method of examination with high-frequency sound waves to obtain images of heart organs. Examination of heart health conditions with echocardiography as an imaging method, serves to detect the potential for heart disease, thus that the right treatment from the evaluation results can be decided. Examination of the source of heart disease with echocardiography was performed using several views, namely the long axis, short axis, two-chamber, and four-chamber. However, the assessment of cardiac function is still carried out conventionally. Thus it is necessary to build a system that can assess cardiac function. This study proposes a feature extraction method for the classification of heart disease based on the left ventricular motion on the short-axis. In this method, feature extraction uses 24 good features for the process of tracking the movement of the left ventricle with optical flow. Each good feature produces four features, namely direction (negative direction and positive direction) and distance (negative distance and positive distance) from the results of left ventricular tracking and produces 96 attributes for the whole process. The features that have been obtained are then processed using several classification algorithms with validation techniques that are, k-folds, and leave one out. The result is a classification algorithm with a gradient boosting classifier method that has the best accuracy. Gradient boosting classifier produces accuracy values with validation techniques for k-folds 90.98%, and leave one out 93.23%. This shows that the gradient boosting classifier can be relied upon for the classification of heart disease using the proposed feature extraction method. In this study, we developed a new feature extraction method from the results of tracking the heart wall using optical flow. This algorithm can produce feature values from the tracking results that can be used to build a knowledge system for the classification of heart health conditions.
- Open Access
- 1 May 2020
- Published by Institute of Advanced Engineering and Science in Indonesian Journal of Electrical Engineering and Computer Science
- Vol. 18 (2) , 1057-1065
Implementation of optical flow: good feature definition for tracking of heart cavity
Echocardiography is a method of examination using high-frequency sound waves to capture images of the heart organ structure. Echocardiography video is used by a doctor to analyze heart wall cavity movements and identify heart disease. Several points of view including the long axis, the two and four cavities in the left ventricle can be used in the examination of heart function. Cardiac assessment is still performed conventionally, which requires a level of thoroughness. This research proposes a method for tracking the movement of the heart wall. In this method, the good feature was defined only in the first frame. Furthermore, the whole frame will be processed by the optical flow method. Good feature definition consists of image enhancement, segmentation and tracking processes using the optical flow. Furthermore, the calculation of contour similarity from the proposed method by forming contour manually using 24 point initialization to draw the heart cavity. The proposed method shows the calculation results with a sensitivity of 90% and an accuracy of 87.451%.
- 1 May 2020
- Published by Institute of Advanced Engineering and Science in Indonesian Journal of Electrical Engineering and Computer Science
- Vol. 18 (2) , 1057-1065
Open AccessImplementation of optical flow: good feature definition for tracking of heart cavity
Echocardiography is a method of examination using high-frequency sound waves to capture images of the heart organ structure. Echocardiography video is used by a doctor to analyze heart wall cavity movements and identify heart disease. Several points of view including the long axis, the two and four cavities in the left ventricle can be used in the examination of heart function. Cardiac assessment is still performed conventionally, which requires a level of thoroughness. This research proposes a method for tracking the movement of the heart wall. In this method, the good feature was defined only in the first frame. Furthermore, the whole frame will be processed by the optical flow method. Good feature definition consists of image enhancement, segmentation and tracking processes using the optical flow. Furthermore, the calculation of contour similarity from the proposed method by forming contour manually using 24 point initialization to draw the heart cavity. The proposed method shows the calculation results with a sensitivity of 90% and an accuracy of 87.451%.
- Open Access
- 28 March 2020
- Published by Insight Society in International Journal on Advanced Science, Engineering and Information Technology
- Vol. 10 (2) , 447-454
Automatic Detection of Fetal Head and Fetal Measurement on Birth Time Estimation
Automatic Detection of Fetal Head and Fetal Measurement on Birth Time Estimation
- 28 March 2020
- Published by Insight Society in International Journal on Advanced Science, Engineering and Information Technology
- Vol. 10 (2) , 447-454
Open AccessAutomatic Detection of Fetal Head and Fetal Measurement on Birth Time Estimation
Automatic Detection of Fetal Head and Fetal Measurement on Birth Time Estimation
- 1 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 177-182
Automatic Segmentation of Heart Cavity in Echocardiography Images: Two & Four-Chamber View Using Iterative Process Method
The heart is a vital part of the human organ which is responsible for receiving and pumping blood throughout the body. According to statistical data held by the World Health Organization noted that heart disease accounts for 31% of human deaths worldwide. Examination of heart health conditions usually uses an echocardiography device with sound waves. In echocardiography, images have speckle noise and need a repair process. Noise speckle is the fine-grained texture-like pattern seen in echocardiography, and indeed in all modalities of clinical ultrasound. This study proposed the two and four-chamber cavity segmentation method in the heart wall cavity. Segmentation process to obtain contour the of heart cavity, required several stages. Improve the image using a median filter to reduce speckle noise, high boost filters and morphology is used to clarify information on the part of the heart cavity. Segmentation cavity using adaptive thresholding and canny edge detection filter to the image. The results of edge detection need to be improved using the region area and collinear. Contour results obtained will be reviewed for the open and closed condition of heart cavity. An iterative process is performed, with increasing high boost filter parameter values that may affect the results of the closed contour. Based on these combinations, the accuracy contour area is 89,409%, and the results of calculation the contour similarity level approach the value of 0. The results of the research have conducted contour searches on the heart wall cavity, and future work focused on the tracking process and measurement of heart contour movements using optical flow.
- 1 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 177-182
Automatic Segmentation of Heart Cavity in Echocardiography Images: Two & Four-Chamber View Using Iterative Process Method
The heart is a vital part of the human organ which is responsible for receiving and pumping blood throughout the body. According to statistical data held by the World Health Organization noted that heart disease accounts for 31% of human deaths worldwide. Examination of heart health conditions usually uses an echocardiography device with sound waves. In echocardiography, images have speckle noise and need a repair process. Noise speckle is the fine-grained texture-like pattern seen in echocardiography, and indeed in all modalities of clinical ultrasound. This study proposed the two and four-chamber cavity segmentation method in the heart wall cavity. Segmentation process to obtain contour the of heart cavity, required several stages. Improve the image using a median filter to reduce speckle noise, high boost filters and morphology is used to clarify information on the part of the heart cavity. Segmentation cavity using adaptive thresholding and canny edge detection filter to the image. The results of edge detection need to be improved using the region area and collinear. Contour results obtained will be reviewed for the open and closed condition of heart cavity. An iterative process is performed, with increasing high boost filter parameter values that may affect the results of the closed contour. Based on these combinations, the accuracy contour area is 89,409%, and the results of calculation the contour similarity level approach the value of 0. The results of the research have conducted contour searches on the heart wall cavity, and future work focused on the tracking process and measurement of heart contour movements using optical flow.