Akila Aiyar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Akila Aiyar has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Akiko Shimada
Department of Geriatric Dentistry, Osaka Dental University, Osaka, Japan
1 shared publication - Carlalberta Verna
Department of Pediatric Oral Health and Orthodontics, University Center for Dental Medicine Basel UZB, University of Basel, Basel, Switzerland
1 shared publication - Giacomo Scuzzo
Eline Clinic Director, Rome, Italy
1 shared publication - Giuseppe Scuzzo
Department of Orthodontics, Università Cattolica del Sacro Cuore, Rome, Italy
1 shared publication - Peter Stoustrup
Section of Orthodontics, Department of Dentistry and Oral Health Aarhus University Aarhus Denmark
1 shared publication - Peter Svensson
Faculty of Dentistry National University of Singapore Singapore Singapore
1 shared publication
Latest Publications
- Open Access
- 14 May 2026
- Published by Wiley in Orthodontics & Craniofacial Research
- Vol. 29 (5) , 926-936
Three‐Dimensional Assessment of Upper Airway Morphology and Sleep‐Disordered Breathing Risk in Unilateral Craniofacial Microsomia: A Pilot Study
Objective: Unilateral craniofacial microsomia (UCM) presents varying unilateral deficiencies of the temporomandibular joint, mandibular ramus, masticatory muscles, and adjacent soft tissues and ear. Reduced mandibular and maxillary dimensions may decrease upper airway volume and may increase the risk of sleep‐disordered breathing (SDB). This retrospective pilot study aimed to evaluate a novel three‐dimensional (3D) method for assessing nasal cavity (NC) and pharyngeal airway (PA) dimensions in growing patients with UCM compared with healthy controls, and to explore the potential associations between airway dimensions and SDB risk using the pediatric Sleep Questionnaire (PSQ). Material and Methods: This retrospective case–control pilot study analysed Cone‐beam computed tomography (CBCT) scans from 11 patients with UCM (mean age 12.7 ± 4.4 years) and 11 age‐matched controls (mean age 12.1 ± 1.1 years). Two calibrated investigators performed airway measurements, including total and partial NC and PA volumes, minimal cross‐sectional area (MCS), and hydraulic diameter. SDB risk in the UCM group was assessed using PSQ scores. Reliability was evaluated with intra‐class correlation coefficients and Dahlberg's formula. Group differences were tested using unpaired t ‐tests. Results: Patients with UCM showed significantly smaller NC volume (9714.9 ± 3032 mm 3 ) than controls (12773.9 ± 1963 mm 3 ; p < 0.0001). PA volume and MCS did not differ significantly. Four of the eleven patients with UCM showed a high PSQ‐based risk of SDB and tended to have smaller airway dimensions. Measurement reliability was acceptable. Conclusions: CBCT‐based 3D assessment of upper airway morphology was feasible in patients with UCM. Patients with UCM demonstrated significantly reduced nasal cavity volume compared with controls. Exploratory analysis suggested that some patients may be at increased risk of SDB; however, these findings require confirmation in larger studies.
- 14 May 2026
- Published by Wiley in Orthodontics & Craniofacial Research
- Vol. 29 (5) , 926-936
Open AccessThree‐Dimensional Assessment of Upper Airway Morphology and Sleep‐Disordered Breathing Risk in Unilateral Craniofacial Microsomia: A Pilot Study
Objective: Unilateral craniofacial microsomia (UCM) presents varying unilateral deficiencies of the temporomandibular joint, mandibular ramus, masticatory muscles, and adjacent soft tissues and ear. Reduced mandibular and maxillary dimensions may decrease upper airway volume and may increase the risk of sleep‐disordered breathing (SDB). This retrospective pilot study aimed to evaluate a novel three‐dimensional (3D) method for assessing nasal cavity (NC) and pharyngeal airway (PA) dimensions in growing patients with UCM compared with healthy controls, and to explore the potential associations between airway dimensions and SDB risk using the pediatric Sleep Questionnaire (PSQ). Material and Methods: This retrospective case–control pilot study analysed Cone‐beam computed tomography (CBCT) scans from 11 patients with UCM (mean age 12.7 ± 4.4 years) and 11 age‐matched controls (mean age 12.1 ± 1.1 years). Two calibrated investigators performed airway measurements, including total and partial NC and PA volumes, minimal cross‐sectional area (MCS), and hydraulic diameter. SDB risk in the UCM group was assessed using PSQ scores. Reliability was evaluated with intra‐class correlation coefficients and Dahlberg's formula. Group differences were tested using unpaired t ‐tests. Results: Patients with UCM showed significantly smaller NC volume (9714.9 ± 3032 mm 3 ) than controls (12773.9 ± 1963 mm 3 ; p < 0.0001). PA volume and MCS did not differ significantly. Four of the eleven patients with UCM showed a high PSQ‐based risk of SDB and tended to have smaller airway dimensions. Measurement reliability was acceptable. Conclusions: CBCT‐based 3D assessment of upper airway morphology was feasible in patients with UCM. Patients with UCM demonstrated significantly reduced nasal cavity volume compared with controls. Exploratory analysis suggested that some patients may be at increased risk of SDB; however, these findings require confirmation in larger studies.
- Open Access
Hybrid Orthodontics for Aesthetic Deep Bite Correction—Case Series and General Clinical Considerations
Background: A range of psychosocial and aesthetic factors motivate patients to undergo orthodontic treatment. The appliance choice depends not only on the type of malocclusion, but also on the aesthetic and functional demands of the patients themselves. Nowadays, digital planning enables the manufacture of individualised and customised orthodontic appliances. However, the predictability of movements with aligner treatment has long been under discussion. This article illustrates, through a series of case reports, how a hybrid approach combining individualised aesthetic orthodontic appliances can improve the predictability of tooth movements, thereby providing additional tools for clinicians charged with choosing the best indicated and biomechanically advantageous technique. To this end, three patients with different malocclusions were treated via a hybrid approach involving clear aligners in the upper arch followed by lingual fixed appliances in the upper and lower arches. All patients were treated using ALIAS lingual PSL 0.018 × 0.018-inch slot brackets and in-house 3D-printed aligners. Findings: The hybrid approach combining aligners and fixed lingual appliances led to the successful resolution of all three complex cases in the series without prolonging treatment time. The superimpositions demonstrate the predictability of even traditionally difficult movements. In particular, the Alias PSL lingual system, used from the beginning, enabled good control of both the torque and inclination of the lower incisors. Conclusions: Combining clear aligners and fixed lingual appliances provides a highly efficient means of treating malocclusions aesthetically. In our cases, the aligners offset the lack of bite-plate effect from the lingual brackets and appliances, providing advantageous biomechanics for rotation correction and control of tip, torque and root movements. Understanding how to exploit the strengths of each appliance enables the clinician to treat adult patients efficaciously, efficiently and aesthetically.
Open AccessHybrid Orthodontics for Aesthetic Deep Bite Correction—Case Series and General Clinical Considerations
Background: A range of psychosocial and aesthetic factors motivate patients to undergo orthodontic treatment. The appliance choice depends not only on the type of malocclusion, but also on the aesthetic and functional demands of the patients themselves. Nowadays, digital planning enables the manufacture of individualised and customised orthodontic appliances. However, the predictability of movements with aligner treatment has long been under discussion. This article illustrates, through a series of case reports, how a hybrid approach combining individualised aesthetic orthodontic appliances can improve the predictability of tooth movements, thereby providing additional tools for clinicians charged with choosing the best indicated and biomechanically advantageous technique. To this end, three patients with different malocclusions were treated via a hybrid approach involving clear aligners in the upper arch followed by lingual fixed appliances in the upper and lower arches. All patients were treated using ALIAS lingual PSL 0.018 × 0.018-inch slot brackets and in-house 3D-printed aligners. Findings: The hybrid approach combining aligners and fixed lingual appliances led to the successful resolution of all three complex cases in the series without prolonging treatment time. The superimpositions demonstrate the predictability of even traditionally difficult movements. In particular, the Alias PSL lingual system, used from the beginning, enabled good control of both the torque and inclination of the lower incisors. Conclusions: Combining clear aligners and fixed lingual appliances provides a highly efficient means of treating malocclusions aesthetically. In our cases, the aligners offset the lack of bite-plate effect from the lingual brackets and appliances, providing advantageous biomechanics for rotation correction and control of tip, torque and root movements. Understanding how to exploit the strengths of each appliance enables the clinician to treat adult patients efficaciously, efficiently and aesthetically.
- Open Access
- 16 August 2022
- Published by Wiley in Journal of Oral Rehabilitation
- Vol. 49 (10) , 954-960
Assessment of masticatory efficiency based on glucose concentration in orthodontic patients: A methodological study
Background: Treatment for malocclusion can cause discomfort and pain in the teeth and periodontium, which may impair masticatory efficiency. The glucose concentration method is widely used to assess masticatory efficiency for its convenience in the clinical situation, although its validity has not been shown.Objectives: The aims were to determine the validity of the glucose concentration method and investigate if this method can be applicable to orthodontic patients with braces.Method: Sixteen healthy individuals (7 men, 9 women, and 26 ± 5 years old) and 16 patients with malocclusions needing orthodontic treatment (5 men, 11 women, and 26 ± 4 years old) participated. Glucose concentration was measured after 5‐, 10‐, and 15‐s mastication of gummy jelly and compared to Hue values obtained from the color‐changing gum method (reference method). In addition, all participants were asked to fill out the Oral Health Impact Profile questionnaire (OHIP) to assess differences in perception related to the mouth before and after the placement of braces.Results: Glucose concentrations were strongly correlated to measures of the two‐color chewing gum methods (R2 = 0.965). Both the glucose extraction and chewing gum hue value were the smallest for 5 s chewing cycles and increased as the number of chewing strokes increased for the 15 s chewing cycles. (Hue: R² = 0.510, p < 0.001; glucose: R² = 0.711, p < 0.001) Masticatory efficiency assessed by both methods was significantly lower in orthodontic patients compared to controls (p < 0.05), even though it was not affected by bonding (p > 0.09). In addition, OHIP scores in physical pain dimension and psychological disability were higher in orthodontic patients than in the control group (p < 0.005).Conclusion: Measurement of glucose concentration was confirmed as a reliable and convenient method for assessing masticatory efficiency. Furthermore, it appears that this method is applicable to patients with braces whose perception in the oral cavity could change.
- 16 August 2022
- Published by Wiley in Journal of Oral Rehabilitation
- Vol. 49 (10) , 954-960
Open AccessAssessment of masticatory efficiency based on glucose concentration in orthodontic patients: A methodological study
Background: Treatment for malocclusion can cause discomfort and pain in the teeth and periodontium, which may impair masticatory efficiency. The glucose concentration method is widely used to assess masticatory efficiency for its convenience in the clinical situation, although its validity has not been shown.Objectives: The aims were to determine the validity of the glucose concentration method and investigate if this method can be applicable to orthodontic patients with braces.Method: Sixteen healthy individuals (7 men, 9 women, and 26 ± 5 years old) and 16 patients with malocclusions needing orthodontic treatment (5 men, 11 women, and 26 ± 4 years old) participated. Glucose concentration was measured after 5‐, 10‐, and 15‐s mastication of gummy jelly and compared to Hue values obtained from the color‐changing gum method (reference method). In addition, all participants were asked to fill out the Oral Health Impact Profile questionnaire (OHIP) to assess differences in perception related to the mouth before and after the placement of braces.Results: Glucose concentrations were strongly correlated to measures of the two‐color chewing gum methods (R2 = 0.965). Both the glucose extraction and chewing gum hue value were the smallest for 5 s chewing cycles and increased as the number of chewing strokes increased for the 15 s chewing cycles. (Hue: R² = 0.510, p < 0.001; glucose: R² = 0.711, p < 0.001) Masticatory efficiency assessed by both methods was significantly lower in orthodontic patients compared to controls (p < 0.05), even though it was not affected by bonding (p > 0.09). In addition, OHIP scores in physical pain dimension and psychological disability were higher in orthodontic patients than in the control group (p < 0.005).Conclusion: Measurement of glucose concentration was confirmed as a reliable and convenient method for assessing masticatory efficiency. Furthermore, it appears that this method is applicable to patients with braces whose perception in the oral cavity could change.