    Mars sample return campaign: biological risk and a proposed sample safety assessment protocol

    by G. McDonnell, B. L. Teece, R. Mackelprang, N. Cressie, J. R. McQuiston, L. E. Mayhew, A. Steele, S. Siljeström, B. M. Ahern, N. Baird, et al.

    Returning surface samples from Mars to Earth has been a major planetary science objective, with the potential for the detection of microbiological life and the possibility of improving our understanding of the origins of life. The National Aeronautics and Space Administration and the European Space Agency assembled a team to assess the level of risk that returned samples could contain potential biohazards. The team was chartered with optimizing previous sample safety assessment strategies, defining what constitutes a biological hazard, developing a protocol to test for biohazards, and establishing a statistical framework to determine if samples may be safe for release from a high-containment facility. This report presents the biological context for a proposed three-step protocol for testing returned samples, including how to determine if microorganisms are present, and if they could be (or were recently) alive.


  • Processing Reusable Medical Devices and End-of-Life Investigation

    by William Sobieski, Terra Kremer, Andrew Tortora, Cindy Rodriguez, Jennifer Rauber, Dmitry Znamensky, Angela Todd, Gerald McDonnell

    Reusable medical devices are intended to be subjected to multiple cycles of clinical processing throughout the life of the device in accordance with manufacturers' instructions for use (IFUs). IFUs should include practical information on the service life of the medical device. This laboratory-based study investigated an approach to support an indefinite lifetime for reusable devices, where the end of life depends on the visual inspection and functional verification provided in the IFU. To evaluate the design features over a broad range of surgical instruments, worst-case, representative devices were identified based on their cumulative features. The devices were subjected to repetitive cycles of processing (cleaning, disinfection, and sterilization). At different stages during the study, the devices were examined for visual effects over time. In addition, extracted levels of total organic carbon and cytotoxicity were assessed. Trend analysis over the study did not show noteworthy effects of device processing over time, including cytotoxic residuals. The results indicated that the effects of repeated cycles of processing on the device tested were negligible regarding physical damage and residual chemical levels. These findings support an indefinite device lifetime using end-of-life indications, based on the IFU and inspection requirements (for cleanliness, damage, and proper function).

  • Open Access

    Non-Sterile Gloves as a Source of Radiation-Tolerant Microorganisms

    by Celine Cabeau, Romain Bolle-Reddat, James Hauschild, Gerald McDonnell

    Radiation methods are widely used for disinfection and sterilization applications. Microorganisms demonstrate known, variable tolerance levels to inactivation with lower doses of ionizing and non-ionizing radiation based on multiple mechanisms of resistance in their structures and nucleic acid repair mechanisms. The radiation dose required to ensure microbial inactivation during sterilization is typically based on the understanding and routine monitoring of the natural population and resistance of microorganisms on products exposed to radiation sterilization processes. This report describes the isolation of Roseomonas mucosa in a device manufacturing environment that was detected during routine device bioburden and dose verification monitoring. Sources of Gram-negative bacteria in the environment were investigated. Non-sterile examination gloves used during manufacturing were found to be a persistent source of R. mucosa and other microbial contaminants. The source of contamination was determined to be from the glove manufacturing process. Maintenance and routine microbiological controls during glove manufacturing, including water systems, are required to reduce the risks of gloves being a source of unexpected microbiological contamination.


  • Affinity and Inactivation of Bacterial Endotoxins for Medical Device Materials

    by Allan Kimble, James Hauschild, Gerald McDonnell

    Endotoxins are high-molecular-weight complexes that contain lipopolysaccharide, protein, and phospholipid originating from the outer membrane of gram-negative bacteria. As gram-negative bacteria are naturally present in a variety of sources, endotoxins are commonly identified as contaminants in manufacturing environments. In industrial applications, endotoxin often is considered difficult to inactivate and to have a strong affinity with surfaces resulting from its hydrophobic chemical structure. This article describes the investigation of the true affinity of endotoxin, from various microbial sources in solution, for medical device material surfaces. In addition, endotoxin reduction was investigated with commonly used sterilization methods such as those based on ionizing radiation, dry and moist heat, and ethylene oxide sterilization. Endotoxin activity was found to be reduced following exposure to a range of sterilization modalities with the degree of activity reduction related to the source of endotoxin and the substrate material upon which it was present.


  • Validation of the Device Feature Approach for Reusable Medical Device Cleaning Evaluations

    by Terra A. Kremer, Jeff Felgar, Neil Rowen, Gerald McDonnell

    The identification of worst-case device (or device set) features has been a well-established validation approach in many areas (e.g., terminal sterilization) for determining process effectiveness and requirements, including for reusable medical devices. A device feature approach for cleaning validations has many advantages, representing a more conservative approach compared with the alternative compendial method of testing the entirety of the device. By focusing on the device feature(s), the most challenging validation variables can be isolated to and studied at the most difficult-to-clean feature(s). The device feature approach can be used to develop a design feature database that can be used to design and validate device cleanliness. It can also be used to commensurately develop a quantitative cleaning classification system that will augment and innovate the effectiveness of the Spaulding classification for microbial risk reduction. The current study investigated this validation approach to verify the efficacy of device cleaning procedures and mitigate patient risk. This feature categorization approach will help to close the existing patient safety gap at the important interface between device manufacturers and healthcare facilities for the effective and reliable processing of reusable medical devices. A total of 56,000 flushes of the device features were conducted, highlighting the rigor associated with the validation. Generating information from design features as a critical control point for cleaning and microbiological quality will inform future digital transformation of the medical device industry and healthcare delivery, including automation.


  • Dry heat sterilization modelling for spacecraft applications

    by Brian Flax, Andrew Tortora, Yen Yeung, Wayne W. Schubert, Gerald McDonnell

    Aims: Inactivation processes using heat are widely used for disinfection and sterilization. Dry heat sterilization of spacecraft equipment has been the preferred microbial inactivation method as part of interplanetary travel protection strategies. An antimicrobial model, based on temperature and exposure time based on experimental data, was developed to provide reliable sterilization processes to be used for interplanetary applications. Methods and Results: Bacillus atrophaeus spores, traditionally used to challenge dry heat sterilization processes, were tested over a range of temperatures in comparison with spores of Bacillus canaveralius that have been shown to have a higher heat resistance profile. D-value and Z-values were determined and used to develop a mathematical model for parametric sterilization applications. The impact of the presence of a contaminating soil, representative of Mars dust, was also tested to verify the practical application of the model to reduce the risk of microbial contamination in such environments. Conclusion: The sterilization model developed can be used as an intrinsic part of risk reduction strategies for interplanetary protection. Significance and Impact: Forward and backward planetary protection strategies to reduce the risks of microbial contamination during interplanetary exploration and research is an important consideration. The development of a modern sterilization model, with consideration of microorganisms identified with higher levels of heat resistance than traditionally deployed in terrestrial applications, allows for the consideration of optimal inactivation processes to define minimum criteria for engineering design. The ability to inactivate living microorganisms, as well as to degrade biomolecules, provides a reliable method to reduce the risk of known and potentially unknown contaminants in future applications.


  • Words Matter: A Commentary and Glossary of Definitions for Microbiological Quality

    by Gerald McDonnell, Hal Baseman, Lena Cordie-Bancroft

    In the design, control, and regulation of the manufacturing and supply of microbiologically controlled devices (including sterile devices) and drug products (including cleaning, disinfection, and sterilization processing and/or aseptic process manufacturing), different terms and/or definitions are often used internationally for similar processes or applications. With product innovations (including combination products and cell-based therapy) and global regulatory influences, there is a growing need to harmonize these definitions. The objective of the Kilmer Regulatory Innovation microbiological quality and sterility assurance glossary is to clarify and harmonize the practical use of terms employed by the different parts of regulated health care product industries internationally and by regulators of the manufacturing and supply of microbiologically controlled health care products internationally. The glossary is expected to continue to evolve; and further industry, academic, and regulatory input is encouraged.


  • Assessing Detergent Residuals for Reusable Device Cleaning Validations

    by Terra A. Kremer, Daniel Olsen, Chad Summers, Alpa Patel, Julie Hoover, Marcin Cieslak, Dmitry Znamensky, Gerald McDonnell

    Cleaning chemistries are detergent-based formulations that are used during the processing of reusable medical devices. Manufacturers are responsible for demonstrating the safety of cleaning formulations when they are used during a device processing cycle, including the risk of device-associated cytotoxicity over the concentration ranges for recommended use and rinsing during cleaning. However, no regulation currently exists requiring manufacturers to demonstrate such safety. Although manufacturers' safety data sheets (SDSs) provide information on the safe use of chemicals for users, this information may not provide sufficient detail to determine the risks of residual chemicals on device surfaces. SDSs are not required to contain a comprehensive list of chemicals used, only those of risk to the user. They should be supplemented with information on the correct concentrations that should be used for cleaning, as well as instructions on the rinsing required to reduce the levels of chemicals to safe (nontoxic) levels prior to further processing. Supporting data, such as toxicity profiles or cytotoxicity data that support the instructions for use, would provide medical device manufacturers and healthcare personnel with the necessary information to make informed decisions about selection and correct use of detergents. In the current work, cytotoxicity profiles for eight commonly used cleaning formulations available internationally were studied. Although all of these products are indicated for use in the cleaning of reusable medical devices, results vary across the serial dilution curves and are not consistent among detergent types. The information presented here can be leveraged by both medical device manufacturers and processing department personnel to properly assess residual detergent risks during processing. This work also serves as a call to cleaning formulation manufacturers to provide this information for all chemistries.


  • Words Matter: A Commentary and Glossary of Definitions for Microbiological Quality

    by Gerald McDonnell, Hal Baseman, Lena Cordie-Bancroft

    In the design, control, and regulation of the manufacturing and supply of microbiologically controlled devices (including sterile devices) and drug products (including cleaning, disinfection, and sterilization processing and/or aseptic process manufacturing), different terms and/or definitions are often used for similar processes or applications internationally. With product innovations (including combination products and cell-based therapy) and global regulatory influences, there is a growing need to harmonize these definitions. The objective of the Kilmer Regulatory Innovation microbiological quality and sterility assurance glossary is to clarify and harmonize the practical use of terms employed by the different parts of regulated healthcare product industries internationally and by regulators of the manufacturing and supply of microbiologically controlled healthcare products internationally. The glossary is expected to continue to evolve, and further industry, academic, and regulatory input is encouraged.