Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Hongwei Zhang has a total of 31 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Model-Free Predictive Repetitive Control of Dual Three-Phase PMSMs for Current Harmonics Suppression

    by Guanghui Yang, Yong Shen, Hongwei Zhang, Xiaojun Zhang, Qiang Chen

    This paper proposes a model-free predictive repetitive control (MFPRC) strategy for dual three-phase permanent magnet synchronous motors (DTP-PMSMs) drive systems, which employs a dual-subspace regulation mechanism to achieve harmonic suppression. By introducing decoupled virtual vectors (DVVs) and the independent disturbance observer, the proposed method realizes explicit closed-loop current control in both the α–β fundamental subspace and the x–y harmonic subspace, thereby overcoming the indirect regulation mechanism inherent in existing model-free predictive control (MFPC) schemes. Furthermore, a repetitive controller-based extended state observer (RCESO) is incorporated in the harmonic subspace to suppress multiple low-order harmonics without complex parallel resonant structures. Meanwhile, a theoretical analysis of system stability characteristics and parameter selection is then provided to clarify the disturbance rejection capability. Finally, experimental results under various operating conditions validate the effectiveness of the proposed MFPRC strategy.

  • Feedforward Dual-Mode Repetitive Control for Single-Phase V2G Inverters in Residential Grids

    by Qiangsong Zhao, Guohui Zhou, Yuanqing Xia, Yongsheng Zhu, Dongdong Yu, Hongwei Zhang

    Vehicle-to-grid (V2G) technology enhances the utilization of renewable energy by enabling electric vehicles to inject stored renewable power into the grid. However, in singlephase residential grids, the grid background harmonics and grid frequency variations directly affect the feed-in grid current quality of the V2G inverter system. To address this issue, this paper proposes a novel feedforward dual-mode repetitive control (FDMRC) scheme, which adjusts adaptively the repetitive control (RC) gains according to the harmonics distribution of feed-in grid current. By introducing the feedforward channels into the dual-mode repetitive control, the FDMRC enlarges the open-loop gains at the frequencies of interest, while enhancing the dynamic performance of the system. In addition, the adaptive RC gains improve the harmonics suppression performance of the FDMRC system under varied grid background harmonics. Furthermore, stability analysis and detailed parameters optimization design for the FDMRC system are presented. The experimental platform of a single-phase V2G inverter is established to verify the effectiveness of the proposed FDMRC scheme, and the experimental results demonstrates that the proposed FDMRC scheme possesses enhanced harmonics suppression performance, strong frequency robustness, and fast dynamic performance under the scenarios of varied grid background harmonics and grid frequency variations.


  • A Novel RC-ESO-ADRC for Harmonics Suppression and Robustness Improvement of Grid-Tied Inverters in a Weak and Distorted Grid

    by Qiangsong Zhao, Qifan Wang, Hongwei Zhang, Yuanqing Xia, Yongqiang Ye

    Repetitive control-based extented state observer (RC-ESO) enhances the estimation accuracy of periodic harmonic disturbances. However, it exhibits a slow convergence rate of disturbance estimation, limited steady-state estimation accuracy, and a lack of systematic design. An improved active disturbance rejection control (ADRC) current control scheme based on a novel RC-ESO (NRC-ESO) is proposed in this paper. An ideal compensation filter (ICF) is used to design the NRC-ESO, achieving a faster convergence rate for disturbance estimation. Additionally, a zero-phase low-pass filter is embedded in the NRC-ESO to reduce the current steady-state error and mitigate the impact of sensors high-frequency noise. The anti-disturbance ability, tracking performance, system stability, and detail parameter optimization design of the NRC-ESO-based ADRC (NRC-ESO-ADRC) are presented. The experimental results reflect the effectiveness of current harmonics suppression and robustness.


  • Top Cited Papers

    Equivalence Relation Analysis and Design of Repetitive Controllers and Multiple Quasi-Resonant Controllers for Single-Phase Inverters

    by Qiangsong Zhao, Hongwei Zhang, Yuanqing Xia, Qiang Chen, Yongqiang Ye

    Repetitive controller (RC) and multiple quasi-resonant controllers (MQ-RSC), both based on internal model principle, are widely used in ac voltage/current control of single-phase inverters due to their high tracking accuracy for sinusoid reference and superior harmonics suppression capabilities. However, both controllers have their respective strengths and weaknesses regarding parameter design complexity, convergence rate, or stability margin. In this paper, the mathematical equivalence between various types of RCs and MQ-RSC are established comprehensively, which offers a new perspective for analyzing and designing these two types of controllers. The equivalent relations reveal the connection between the internal model coefficients of RCs and the equivalent resonant bandwidths of MQ-RSC. Based on this equivalent relations, a novel design way of RCs is proposed to enhance the frequency robustness. Furthermore, a new MQ-RSC design method is also put forward to simplify the design process. Experimental results on a 1.5-kW single-phase grid-tied inverter validate the accuracy of the equivalence relations and showcase their valuable roles in the design of RC and MQ-RSC.


  • Fractional Order Feedforward Odd-Harmonic Repetitive Controller for Grid-Tied Inverters in Microgrids

    by Gong Zhang, Qiangsong Zhao, Yan Wang, Hongwei Zhang, Guohui Zhou, Aihui Wang, Shengjun Wen

    The harmonic suppression performance of the odd-harmonic repetitive controller (ORC) will decrease when the microgrid frequency fluctuates due to power imbalance. This article presents a novel fractional order feedforward odd-harmonic repetitive controller (FO-FORC) for grid-tied inverters in microgrids. The feedforward ORC (FORC) with a feedforward channel has a much higher open-loop gain and a wider bandwidth at odd-harmonic frequencies than conventional ORC (CORC) without a feedforward channel. Therefore, the FORC can more efficiently suppress the odd harmonic of grid current while using fewer storage units. Nevertheless, the ratio of the sampling frequency of the FORC to the microgrid frequency can only be an integer, which degrades the harmonics suppression performance of the FORC with a fixed sampling frequency when the fundamental grid frequency changes in a relatively wide range. In order to settle the problem, based on a Thiran infinite impulse response (IIR) filter, this article proposes the FO-FORC with frequency adaptability to ensure that the resonance peaks of FO-FORC maintain at the real disturbance signal frequencies by online adjusting only a few coefficients of low-order IIR filter. The stability analysis, parameters design, and performance estimation are given. Comparative experiments verify the feasibility and superiority of the presented FO-FORC.


  • Open Access

    Fractional-Order Phase Lead Compensation Multirate Repetitive Control for Grid-Tied Inverters

    by Fen Liang, Ho-Joon Lee, Hongwei Zhang

    To reduce computational load and memory consumption, multirate repetitive control (MRC) with downsampling rates provides a flexible and efficient design for proportional-integral multi-resonant repetitive control (PIMR-RC) systems for grid-tied inverters. However, in MRC systems, repetitive controllers with low sampling rates produce low delay periods, and integer-order phase lead compensation may cause undercompensation or overcompensation. These imprecise linear phase lead compensations may result in deteriorated control performance. To address these problems, based on an infinite impulse response (IIR) filter, a fractional-order phase lead proportional-integral multi-resonant multirate repetitive control (FPL-PIMR-MRC) is proposed for grid-tied inverters in this paper. The proposed method can provide a suitable fractional phase lead step to achieve a wide stability region, minor tracking errors, and low hardware costs. The IIR fractional-order lead filter design, stability analysis, and the step-by-step parameter tuning of the FPL-PIMR-MRC system are derived in detail. Finally, simulation performed confirms the feasibility and effectiveness of the proposed scheme.


  • Open Access

    Improved Repetitive Control for an LCL-Type Grid-Tied Inverter with Frequency Adaptive Capability in Microgrids

    by Hongwei Zhang, Qiangsong Zhao, Shuanghong Wang, Xuebin Yue

    Repetitive control (RC), which can track any periodic signal with a known integer period with zero steady-state error, is widely used for current control of grid-tied inverters in microgrids. However, the inherent one fundamental period time delay, leads to poor dynamic performance. Furthermore, the performance of conventional RC (CRC) will degrade when operating at a high variation grid frequency. Therefore, this paper proposes a frequency adaptive improved RC (FA-IRC) for grid-tied inverters. The improved RC (IRC) consists of a repetitive controller with a modified internal model filter, plus a proportional controller. In comparison to the CRC, the IRC has a good dynamic response, because it provides a higher gain and a wider bandwidth at the resonant frequency. Moreover, to achieve the frequency adaptability of the IRC, a fractional delay, based on a finite impulse response (FIR) filter, is built into the IRC system, to ensure that the resonant frequency of the IRC is approximately equal to the actual grid frequency and harmonic frequency. Stability analysis and characteristic analysis of the FA-IRC system are reported in this paper. Simulations are conducted, to demonstrate the validity of the proposed method.


  • Open Access

    Novel Active Damping Design Based on a Biquad Filter for an LLCL Grid-Tied Inverter

    by Bin Wang, Qiangsong Zhao, Gong Zhang, Hongwei Zhang, Kaiyue Liu, Xuebin Yue

    LLCL filters for grid-tied inverters have been adopted to get better performance for the harmonics near the switching frequency than commonly used LCL filters. However, the resonant peak caused by a pair of unstable resonance poles of the LLCL filters is introduced and makes the system become unstable. In this paper, a biquad filter composed of a notch filter and a resonator is introduced to restrain the resonant peak. In this method, the resonance point and the notch point of the biquad filter are placed at the appointed frequency, and the resonant peak is transferred to the stable area by phase transformation, so that the system does not cross −180° at the resonant peak. This method makes the system have higher control bandwidth and stronger robustness even in a weak power grid. Meanwhile, a proportional-integral multiresonant repetitive controller is used to restrain low-frequency current harmonics and improve the steady-state and dynamic performance of the control system. Furthermore, based on the active damping of the biquad filter, the stability criterion of the control system under a weak power grid is given. Finally, the accuracy of the analysis and the effectiveness of the method is verified by simulations.


  • Improved Dual-Mode Repetitive Control for Grid-Connected Inverters

    by Hao Chen, Qiangsong Zhao, Hongwei Zhang, Kaiyue Liu, Gong Zhang, Bin Wang

    In this paper, a dual-mode repetitive control in parallel with proportional gain is proposed, and a fractional delay is added in the case of grid frequency perturbation to ensure the suppression capability of output current harmonics. Firstly, the principle of the compound controller is analysed. Secondly, the theoretical basis for the stability and parameter design of the composite controller is analysed, and the parameter design is carried out based on a single-phase LCL-type grid-connected inverter. Finally, the fractional-delay part is added under consideration of grid frequency disturbance and its stability is verified. The experimental results verify that the composite controller proposed in this paper has excellent harmonic suppression capability and fast dynamic performance.