Yan Dong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Yan Dong has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Dongzhi Zhang
State Key Laboratory of Chemical Safety, College of Control Science and Engineering, China University of Petroleum (East China), Qingdao 266580, China
5 shared publications Wenzheng An
3 shared publicationsZihu Wang
3 shared publicationsBotao Gao
2 shared publicationsJuntai Lv
2 shared publicationsKangshuai Li
2 shared publications
Latest Publications
- 5 August 2025
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 288, 117844
An artificial intelligence-assisted, kilometer-scale wireless and wearable biochemical sensing platform for monitoring of key biomarkers in urine
- 5 August 2025
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 288, 117844
An artificial intelligence-assisted, kilometer-scale wireless and wearable biochemical sensing platform for monitoring of key biomarkers in urine
- Open Access
- 15 November 2024
- Published by Springer Nature in Nano-Micro Letters
- Vol. 17 (1) , 1-15
An Artificial Intelligence-Assisted Flexible and Wearable Mechanoluminescent Strain Sensor System
The complex wiring, bulky data collection devices, and difficulty in fast and on-site data interpretation significantly limit the practical application of flexible strain sensors as wearable devices. To tackle these challenges, this work develops an artificial intelligence-assisted, wireless, flexible, and wearable mechanoluminescent strain sensor system (AIFWMLS) by integration of deep learning neural network-based color data processing system (CDPS) with a sandwich-structured flexible mechanoluminescent sensor (SFLC) film. The SFLC film shows remarkable and robust mechanoluminescent performance with a simple structure for easy fabrication. The CDPS system can rapidly and accurately extract and interpret the color of the SFLC film to strain values with auto-correction of errors caused by the varying color temperature, which significantly improves the accuracy of the predicted strain. A smart glove mechanoluminescent sensor system demonstrates the great potential of the AIFWMLS system in human gesture recognition. Moreover, the versatile SFLC film can also serve as a encryption device. The integration of deep learning neural network-based artificial intelligence and SFLC film provides a promising strategy to break the “color to strain value” bottleneck that hinders the practical application of flexible colorimetric strain sensors, which could promote the development of wearable and flexible strain sensors from laboratory research to consumer markets.
- 15 November 2024
- Published by Springer Nature in Nano-Micro Letters
- Vol. 17 (1) , 1-15
Open AccessAn Artificial Intelligence-Assisted Flexible and Wearable Mechanoluminescent Strain Sensor System
The complex wiring, bulky data collection devices, and difficulty in fast and on-site data interpretation significantly limit the practical application of flexible strain sensors as wearable devices. To tackle these challenges, this work develops an artificial intelligence-assisted, wireless, flexible, and wearable mechanoluminescent strain sensor system (AIFWMLS) by integration of deep learning neural network-based color data processing system (CDPS) with a sandwich-structured flexible mechanoluminescent sensor (SFLC) film. The SFLC film shows remarkable and robust mechanoluminescent performance with a simple structure for easy fabrication. The CDPS system can rapidly and accurately extract and interpret the color of the SFLC film to strain values with auto-correction of errors caused by the varying color temperature, which significantly improves the accuracy of the predicted strain. A smart glove mechanoluminescent sensor system demonstrates the great potential of the AIFWMLS system in human gesture recognition. Moreover, the versatile SFLC film can also serve as a encryption device. The integration of deep learning neural network-based artificial intelligence and SFLC film provides a promising strategy to break the “color to strain value” bottleneck that hinders the practical application of flexible colorimetric strain sensors, which could promote the development of wearable and flexible strain sensors from laboratory research to consumer markets.
- Top Cited PapersOpen Access
- 13 June 2024
- Published by Springer Nature in npj Flexible Electronics
- Vol. 8 (1) , 1-11
An artificial intelligence-assisted microfluidic colorimetric wearable sensor system for monitoring of key tear biomarkers
The precise, simultaneous, and rapid detection of essential biomarkers in human tears is imperative for monitoring both ocular and systemic health. The utilization of a wearable colorimetric biochemical sensor exhibits potential in achieving swift and concurrent detection of pivotal biomarkers in tears. Nevertheless, challenges arise in the collection, interpretation, and sharing of data from the colorimetric sensor, thereby restricting the practical implementation of this technology. To overcome these challenges, this research introduces an artificial intelligence-assisted wearable microfluidic colorimetric sensor system (AI-WMCS) for rapid, non-invasive, and simultaneous detection of key biomarkers in human tears, including vitamin C, H+(pH), Ca2+, and proteins. The sensor consists of a flexible microfluidic epidermal patch that collects tears and facilitates the colorimetric reaction, and a deep-learning neural network-based cloud server data analysis system (CSDAS) embedded in a smartphone enabling color data acquisition, interpretation, auto-correction, and display. To enhance accuracy, a well-trained multichannel convolutional recurrent neural network (CNN-GRU) corrects errors in the interpreted concentration data caused by varying pH and color temperature in different measurements. The test set determination coefficients (R2) of 1D-CNN-GRU for predicting pH and 3D-CNN-GRU for predicting the other three biomarkers were as high as 0.998 and 0.994, respectively. This correction significantly improves the accuracy of the predicted concentration, enabling accurate, simultaneous, and quick detection of four critical tear biomarkers using only minute amounts of tears ( ~ 20 μL). This research demonstrates the powerful integration of a flexible microfluidic colorimetric biosensor and deep-learning algorithm, which holds immense potential to revolutionize the fields of health monitoring.
- 13 June 2024
- Published by Springer Nature in npj Flexible Electronics
- Vol. 8 (1) , 1-11
Top Cited PapersOpen AccessAn artificial intelligence-assisted microfluidic colorimetric wearable sensor system for monitoring of key tear biomarkers
The precise, simultaneous, and rapid detection of essential biomarkers in human tears is imperative for monitoring both ocular and systemic health. The utilization of a wearable colorimetric biochemical sensor exhibits potential in achieving swift and concurrent detection of pivotal biomarkers in tears. Nevertheless, challenges arise in the collection, interpretation, and sharing of data from the colorimetric sensor, thereby restricting the practical implementation of this technology. To overcome these challenges, this research introduces an artificial intelligence-assisted wearable microfluidic colorimetric sensor system (AI-WMCS) for rapid, non-invasive, and simultaneous detection of key biomarkers in human tears, including vitamin C, H+(pH), Ca2+, and proteins. The sensor consists of a flexible microfluidic epidermal patch that collects tears and facilitates the colorimetric reaction, and a deep-learning neural network-based cloud server data analysis system (CSDAS) embedded in a smartphone enabling color data acquisition, interpretation, auto-correction, and display. To enhance accuracy, a well-trained multichannel convolutional recurrent neural network (CNN-GRU) corrects errors in the interpreted concentration data caused by varying pH and color temperature in different measurements. The test set determination coefficients (R2) of 1D-CNN-GRU for predicting pH and 3D-CNN-GRU for predicting the other three biomarkers were as high as 0.998 and 0.994, respectively. This correction significantly improves the accuracy of the predicted concentration, enabling accurate, simultaneous, and quick detection of four critical tear biomarkers using only minute amounts of tears ( ~ 20 μL). This research demonstrates the powerful integration of a flexible microfluidic colorimetric biosensor and deep-learning algorithm, which holds immense potential to revolutionize the fields of health monitoring.
- Open Access
- 8 July 2022
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 8 (27) , eabo7049
Battery-free, tuning circuit–inspired wireless sensor systems for detection of multiple biomarkers in bodily fluids
Tracking the concentration of biomarkers in biofluids can provide crucial information about health status. However, the complexity and nonideal form factors of conventional digital wireless schemes impose challenges in realizing biointegrated, lightweight, and miniaturized sensors. Inspired by the working principle of tuning circuits in radio frequency electronics, this study reports a class of battery-free wireless biochemical sensors: In a resonance circuit, the coupling between a sensing interface and an inductor-capacitor oscillator through a pair of varactor diodes converts a change in electric potential into a modulation in capacitance, resulting in a quantifiable shift of the resonance circuit. Proper design of sensing interfaces with biorecognition elements enables the detection of various biomarkers, including ions, neurotransmitters, and metabolites. Demonstrations of “smart accessories” and miniaturized probes suggest the broad utility of this circuit model. The design concepts and sensing strategies provide a realistic pathway to building biointegrated electronics for wireless biochemical sensing.
- 8 July 2022
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 8 (27) , eabo7049
Open AccessBattery-free, tuning circuit–inspired wireless sensor systems for detection of multiple biomarkers in bodily fluids
Tracking the concentration of biomarkers in biofluids can provide crucial information about health status. However, the complexity and nonideal form factors of conventional digital wireless schemes impose challenges in realizing biointegrated, lightweight, and miniaturized sensors. Inspired by the working principle of tuning circuits in radio frequency electronics, this study reports a class of battery-free wireless biochemical sensors: In a resonance circuit, the coupling between a sensing interface and an inductor-capacitor oscillator through a pair of varactor diodes converts a change in electric potential into a modulation in capacitance, resulting in a quantifiable shift of the resonance circuit. Proper design of sensing interfaces with biorecognition elements enables the detection of various biomarkers, including ions, neurotransmitters, and metabolites. Demonstrations of “smart accessories” and miniaturized probes suggest the broad utility of this circuit model. The design concepts and sensing strategies provide a realistic pathway to building biointegrated electronics for wireless biochemical sensing.
- Open Access
- 18 June 2012
- Published by Springer Nature in Acta Pharmacologica Sinica
- Vol. 33 (7) , 861-872
Atorvastatin enhances neurite outgrowth in cortical neurons in vitro via up-regulating the Akt/mTOR and Akt/GSK-3β signaling pathways
Aim: Methods: Results: Conclusion:
- 18 June 2012
- Published by Springer Nature in Acta Pharmacologica Sinica
- Vol. 33 (7) , 861-872
Open AccessAtorvastatin enhances neurite outgrowth in cortical neurons in vitro via up-regulating the Akt/mTOR and Akt/GSK-3β signaling pathways
Aim: Methods: Results: Conclusion: