GSGregory James Schneider

Gregory James Schneider

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Gregory James Schneider has a total of 35 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Intercalary Allograft Reconstruction of the Femur: A Cadaveric Comparison of Intramedullary and Plate Fixation Techniques

    by Yazan Kadkoy, Gregory James Schneider, Joseph Anthony Ippolito, Thomas Philip Helbig, Vijay Subramanian, Jonathan Rene Lopez, David N. Paglia, Joseph Benevenia

    Intercalary reconstruction following diaphyseal tumor resection is advantageous in that they preserve the joint above and below. Recently, intramedullary devices such as intramedullary nails (IMN), photodynamic bone stabilizing system (PBSS), and intercalary endoprosthetic reconstruction (EPR) have become increasingly used. Understanding the tradeoffs associated with each construct as well as characterizing their mechanical stability is essential for making a patient‐specific decision for reconstruction. The mechanical properties of four different constructs used in the reconstruction of segmental defects in a femur model were compared: Double plate (DP) allograft secured by 90–90 plating, allograft secured by IMN and plate fixation, allograft secured by PBSS and plate fixation, as well as an intercalary prosthesis (EPR). Samples were tested in axial, bending and torsional loading, and mechanical properties were compared. The EPR during anterior–posterior bending had 51.63% of the displacement compared to the DP ( p = 0.0007), and 55% of the creep over 100 cycles ( p = 0.0126) with a rigidity of 201.3% ( p = 0.0067). This difference also exists for cyclic torsion where the EPR rotates 52.32% the amount of the DP ( p = 0.0044) and has 4.44% of the creep ( p < 0.0001). The PBSS and IMN constructs had comparable results across all tests ( p > 0.05). Overall, the EPR has comparable or superior mechanical stability to the DP, while the PBSS and IMN have similar mechanical properties. Together, these results can be used as a guide for surgeons to choose different implants depending on individual patient needs.

  • Open Access

    A Comparison of Radiographic Alignment between Bilateral and Unilateral Interbody Cages in Patients Undergoing Transforaminal Lumbar Interbody Fusion

    by Mark James Lambrechts, Jeremy Heard, Nicholas D'Antonio, John Bodnar, Gregory Schneider, Evan Bloom, Jose Canseco, Barrett Woods, Ian David Kaye, Mark Kurd, et al.

    Study Design: Retrospective cohort study.Purpose: To compare radiographic outcomes between unilateral and bilateral cage placement in transforaminal lumbar interbody fusions (TLIF) and to determine if the rate of fusion at the 1-year postoperative point was different in patients who received bilateral versus unilateral cages.Overview of Literature: There is no clear evidence to dictate whether bilateral or unilateral cages promote superior radiographic or surgical outcomes in TLIF.Methods: Patients >18 years old who underwent primary one- or two-level TLIFs at our institution were identified and propensitymatched in a 3:1 fashion (unilateral:bilateral). Patient demographics, surgical characteristics, and radiographic outcomes, including vertebral endplate obliquity, segmental lordosis, subsidence, and fusion status, were compared between groups.Results: Of the 184 patients included, 46 received bilateral cages. Bilateral cage placement was associated with greater subsidence (1.06±1.25 mm vs. 0.59±1.16 mm, p=0.028) and enhanced restoration of segmental lordosis (5.74°±14.1° vs. −1.57°±10.9°, p=0.002) at the 1-year postoperative point, while unilateral cage placement was associated with an increased correction of endplate obliquity (−2.02°±4.42° vs. 0.24°±2.81°, p<0.001). Bilateral cage placement was significantly associated with radiographic fusion on bivariate analysis (89.1% vs. 70.3%, p=0.018) and significantly predicted radiographic fusion on multivariable regression analysis (estimate, 1.35; odds ratio, 3.87; 95% confidence interval, 1.51–12.05; p=0.010).Conclusions: Bilateral interbody cage placement in TLIF procedures was associated with restoration of lumbar lordosis and increased fusion rates. However, endplate obliquity correction was significantly greater for patients who received a unilateral cage.


  • Arthroscopic Lysis of Adhesions for the Stiff Total Knee Arthroplasty

    by Andrew R. Leggett, Gregory J. Schneider, Yair D. Kissin, Edward Y. Cheng, Stephen R. Rossman

    Background: Arthroscopic lysis of adhesions is a treatment option for patients with painful, stiff knees as a result of arthrofibrosis following knee arthroplasty, in whom prior manipulation under anesthesia (MUA) has failed. Typically, nonoperative treatment in these patients has also failed, including aggressive physiotherapy, stretching, dynamic splinting, and various pain-management measures or medications. Range of motion in these patients is often suboptimal, and any gains in flexibility will likely have hit a plateau over many months. The goal of performing lysis of adhesions is to increase the range of motion in patients with knee stiffness following total knee arthroplasty, as well as to reduce pain and restore physiologic function of the knee, enabling activities of daily living. Description: This is a straightforward surgical technique that can be performed in a single stage. The preoperative range of motion is documented after induction of general anesthesia. The procedure begins with the establishment of standard medial and lateral parapatellar arthroscopic portals. A blunt trocar is introduced into the knee, and blunt, manual lysis of adhesions is performed in the suprapatellar pouch and the medial and lateral gutters with use of a sweeping motion after piercing and perforating the scarred adhesive bands or capsular tissue. Next, the arthroscope is inserted into the knee, and a diagnostic arthroscopy is performed. Bands of fibrous tissue are released and resected with use of electrocautery and a 4.0-mm arthroscopic shaver. Next, the posterior cruciate ligament (PCL) is visualized in full flexion. If PCL tightness is observed, the PCL can be released from its femoral origin until the flexion gap is increased. This portion of the procedure can include either partial or full release of the PCL, as indicated. Next, the arthroscope is removed and the ipsilateral hip is flexed to 90° for a standard MUA. Gentle force is applied to the proximal aspect of the tibia, and the knee is flexed. After completing the MUA, immediate post-intervention range of motion of the knee is documented, and the patient is provided with a continuous passive motion (CPM) machine set to the maximum flexion and extension achieved in the operating room. Alternatives: Nonoperative treatment of a stiff knee following total knee arthroplasty is well documented in the current literature. Range of motion has been shown to increase in patients undergoing proper pain management, aggressive physical therapy, and closed MUA in the acute postoperative setting. Additionally, more severe cases of established arthrofibrosis despite prior MUA can be treated with an open lysis of adhesions 1–3 . Rationale: Arthroscopic lysis of adhesions with PCL release versus resection has been well described previously. This procedure has been shown to benefit patients in whom initial nonoperative treatment has failed. Additionally, this procedure is not limited to the immediate acute postoperative period like standard MUA 3 . To our knowledge, no technique video has been published outlining arthroscopic lysis of adhesions for a stiff knee following total knee arthroplasty. Expected Outcomes: This procedure has been shown to provide an immediate and lasting improvement in the flexion and extension arc of the knee, as well as improved functional outcomes. Patients should be educated that improvements gained in the operating room must be sustained through physical therapy. In a study of 32 patients who underwent arthroscopic lysis of adhesions for moderately severe arthrofibrosis following a total knee arthroplasty, Jerosch and Aldawoudy reported a mean postoperative flexion of 119° in the operating room and 97° at the time of the latest follow-up. Eight patients with extensor lag showed improvement from 27° to 4°. Average Knee Society scores improved from 70 points preoperatively to 86 points at the time of the latest follow-up 4 . Their article showed that arthroscopic treatment of stiffness following total knee arthroplasty is a safe and effective form of treatment. Important Tips: Perform manual lysis of adhesions with a trocar prior to inserting the arthroscope in order to improve visualization and access. Utilize all portals and accessory portals interchangeably in order to improve access. Prescribe physical therapy with or without CPM machine immediately following surgery in order to maintain correction. Utilize pump inflow in order to help distend the tightened capsule. Protect the prosthetic surface from scratches during portal establishment. Loss of flexion implies scarring in the suprapatellar pouch and/or intercondylar notch, or PCL tightness. Loss of extension implies a tight posterior capsule, posterior osteophytes, or scarring of the PCL stump. A motorized shaver is the best tool for treatment of dense fibrous tissue, but be sure not to scratch metal total knee components. Acronyms and Abbreviations: TKA = total knee arthroplasty ROM = range of motion CT = computed tomography MRI = magnetic resonance imaging ESR = erythrocyte sedimentation rate CRP = C-reactive protein


  • Disclosures Undisclosed

    by Cory F. Janney, Kiya Shazadeh Safavi, Gregory J. Schneider, Daniel C. Jupiter, Vinod K. Panchbhavi

    Background: The Centers for Medicare & Medicaid Services (CMS) Open Payments public database, resulting from the Physician Payments Sunshine Act of 2010, was designed to increase transparency of physicians’ financial relationships with pharmaceutical manufacturers. We compared physician-reported conflict-of-interest (COI) disclosures in journal articles with this database to determine any discrepancies in physician-reported disclosures. Methods: COIs reported by authors from 2014 through 2016 were analyzed in 3 journals: Foot & Ankle International (FAI), The Journal of Bone & Joint Surgery (JBJS), and The Journal of Arthroplasty (JOA). Payment information in the CMS Open Payments database was cross-referenced with each author’s disclosure statement to determine if a disclosure discrepancy was present. Results: We reviewed 3,465 authorship positions (1,932 unique authors) in 1,770 articles. Within this sample, 7.1% of authorships had a recorded undisclosed COI (disclosure discrepancy), and 13.2% of articles had first and/or last authors with a disclosure discrepancy. Additionally, we saw a great variation in the percentage of authorships with disclosure discrepancies among the journals (JBJS, 2.3%; JOA, 3.6%; and FAI, 23.7%). Conclusions: Discrepancies exist between payment disclosures made by authors and those published in the CMS Open Payments database. Although the percentage of articles with these discrepancies varies widely among the journals that were analyzed in this study, no trend was found when analyzing the number of discrepancies over the 3-year period. Clinical Relevance: COI disclosures are important for the interpretation of study results and need to be accurately reported. However, COI disclosure criteria vary among orthopaedic journals, causing uncertainty regarding which conflicts should be disclosed.