  • An Advanced Control Strategy for Enhancing Voltage Support With Minimum Active Power Curtailment During Asymmetrical Faults

    by Suresh Maganti, Narayana Prasad Padhy

    During severe voltage events in power systems (sag, swell, and their co-occurrence), Distributed Generators (DGs) must remain connected for a specific duration due to stringent grid code requirements. Researchers have developed various control schemes for reactive power injection and consumption to support the voltage during this period. However, significant challenges remain, particularly during asymmetrical short-circuit faults. Over-voltage in the healthy phases of a three-phase system complicates reactive power injection. Additionally, active power curtailment is often necessary during reactive power adjustments, which needs to be minimized without compromising voltage support. This paper proposes an advanced voltage support control strategy to address the over-voltage issue during asymmetrical faults and enhance voltage support with minimum active power curtailment in compliance with voltage limits and safe current operating limits. The proposed voltage support scheme adapted phase- wise reactive power injection to address the over-voltage issue, which successfully regulates positive sequence voltage and reduces negative and zero sequence voltages. Based on the voltage event, the active power curtailment is minimized by adjusting active power delivery between healthy and faulty phases after reactive current reference generation. The proposed scheme is validated on a laboratory prototype of a grid-connected DG using a three-phase, four-leg converter under various voltage event severities and DG power generation scenarios.


  • An Advanced Control Strategy for a Weak Grid-Connected DG for Enhancing Voltage Support During Co-occurrence of Sag and Swell

    by Suresh Maganti, Narayana Prasad Padhy

    Numerous control strategies for voltage support are developed to encounter the voltage issues(sag, swell, low voltage, and high voltage). Yet, there is a significant gap in the voltage support concept, such as reduction of zero-sequence voltage along with negative sequence voltage and providing the voltage support during co-occurrence of voltage sag and swell (CVSS) in the phases of a three-phase grid-tied converter. Many reasons that can cause CVSS. In this situation, the conventional control strategies have failed to support the voltage because the maximum voltage of the healthy phase voltages constrains the reactive power injection. Therefore, the reactive power injection/consumption is zero in the case of CVSS. In this paper, the proposed work presents a flexible reactive power control to enhance the voltage support during the CVSS in the phases of the system. It generates phase- wise current references for controlling appropriate reactive power subjected to safe current limits when the voltage sag, swell, and co-existence are detected in the phases. Under normal system operation, the behavior of the proposed control is the same as conventional. The proposed control is implemented on the grid-tied three-phase four-leg inverter, and the experimentation results show the effectiveness of the proposed control.


  • A Feedback-Based Flexible Compensation Strategy for a Weak-Grid-Tied Current-Controlled Converter Under Unbalanced and Harmonic Conditions

    by Suresh Maganti, Narayana Prasad Padhy

    Due to ever-increasing power demand and high renewable energy penetration, the power system's harmonics and voltage unbalancing have become significant power quality issues. In this aspect, because of the multi-functioning ability of the power electronic converters, the grid-connected power electronic converter-based distributed generations are expected to provide desired compensation whenever required. Especially in a weak grid environment, the compensation draws more attention due to constricted coupling between the voltage and current at the point of common coupling(PCC) as a consequence of high grid impedance. Therefore, this paper presents a feedback-based flexible compensation strategy for a weak grid-tied distributed generation(DG) to enhance the compensation of harmonics and voltage unbalance in the system. The main uniqueness of the proposed work is to seamlessly embed a flexible harmonic loop with a fundamental current control loop for achieving three control targets: voltage harmonic compensation, DG line current harmonic rejection, and voltage unbalance compensation. Achieving control targets require voltage feedback and no need to measure non-linear load current. In order to execute flexible harmonic compensation (i.e., from voltage harmonic compensation to DG line current harmonic rejection) through the harmonic loop, the proposed strategy generates a harmonic reference from voltage feedback and inherent current feedback. The delay introduced by the harmonic compensators is accurately compensated distinctly to improve the performance of the harmonic loop. The voltage unbalance compensation is achieved through the fundamental current control loop by improving fundamental positive sequence voltage and decreasing negative sequence components concurrently. To enhance the flexibility between two different targets (i.e., flexible harmonic compensation and voltage unbalance compensation), the harmonic and unbalanced compensations are executed on an individual target basis, subjected to the converter's maximum current and system voltage constraints. The proposed compensation strategy offers better harmonic suppression and voltage unbalance compensation than conventional methods. Because it exactly acts upon modulation signals and directly regulates sequence components and voltage harmonics. Further, the proposed control's detailed design and stability analysis is presented, and its superiority is validated through simulations and real-time experimentations.


  • Analysis and Design of PLL Less Current Control for Weak Grid-Tied LCL-Type Voltage Source Converter

    by Suresh Maganti, Narayana Prasad Padhy

    For a weak grid-tied $LCL$ -type converter, the conventional current control interacts with a phase-locked loop (PLL) through the voltage at the point of common coupling (PCC). Thus, the dynamics of PLL deteriorate converter stability, hence leads to system instability issues. To avoid the instability issues due to PLL, a PLL less current control is proposed for $LCL$ -type grid-connected converter with capacitor-current-feedback active damping. The analysis and design of the proposed PLL less current control is presented in this article, and the performance of the proposed control is compared with conventional current control (i.e., PLL without bandpass (BP) filter) and improved conventional control (i.e., PLL + BP filter). A small-signal model is developed by considering the dynamics of the PLL and BP filter to show the impact of the current control parameters on converter output impedance. An impedance-based stability analysis is performed to show the system stability against short circuit ratio (SCR) variation for three different current control scenarios, such as proposed PLL less, PLL with a BP filter, and PLL without BP filter. The proposed current control works in both stiff grid and weak grid environments. It has strong robustness against a wide range of variation in grid impedance and more adaptable to grid frequency changes. The performance of the proposed control is verified during grid voltage harmonics, unbalanced voltage, and grid voltage variations and further validated by comparing with the conventional control. In addition to the features mentioned above, the proposed current control is able to operate stably at SCR = 1. Finally, the experiment shows the superiority of the proposed control over conventional control.