CXCheng Xie

Cheng Xie

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Cheng Xie has a total of 18 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Experimental Platform for Measuring Electrical Discharges in Long Air Gaps With Floating Objects and Its Applications Under Lightning Impulse

    by Jiachen Gao, Linong Wang, Shaocheng Wu, Cheng Xie, Bin Song, Yaqi Fang

    Long air gaps containing floating objects are common gaps in power transmission and substation projects. Investigating the discharge mechanism of gaps helps improve the power grid operational reliability. This paper presents an experimental platform for measuring the electrical discharges in long air gaps with floating objects, which can measure the applied voltage and the discharge current, and capture the images of the discharge process. By analyzing these measured data, the breakdown voltage characteristics of the gap can be explained. In a long air gap with a floating conductive object under lightning impulse, as the floating object moves from the HV electrode to the ground potential electrode, the breakdown voltage first decreases and then increases, producing a minimum breakdown voltage area (MBVA). In this paper, the experimental platform was used to explain the formation of MBVA as an application example. The results show that the formation of MBVA is related to the timing relationship between the breakdown of sub-gap 1 and the discharge in sub-gap 2 entering the final jump. The minimum breakdown voltage occurs at the shortest sub-gap 1 ensuring that the discharge in sub-gap 2 enters the final jump just as sub-gap 1 is broken down.


  • Breakdown Characteristics of a Long Air Gap Containing a Floating Conductor Under Positive Switching Impulse

    by Jiachen Gao, Linong Wang, Shaocheng Wu, Cheng Xie, Lei Liu, Enwen Li, Tingting Wang, Andrea Cavallini

    Experiments on the breakdown characteristics of a long air gap containing a floating conductor under switching impulse are carried out to address issues in live-line work engineering. The effects of gap distance, floating conductor structure, wavefront time, and high altitude on breakdown voltage are investigated, respectively. The results show that a floating conductor with sharp protrusions reduces the breakdown voltage and produces the lowest breakdown voltage area (LBA). The maximum reduction rate of the breakdown voltage and the position of the LBA vary with the gap distance. The position of the LBA is also related to the floating conductor structure. The results indicate that different floating conductor structures with similar electric field distortions have a similar effect on the breakdown voltage. For the effect of wavefront time on breakdown characteristics, the results show that the breakdown voltage under switching impulse with a long wavefront time is higher than that under a standard switching impulse. For the effect of high altitude, the results show that the LBA at high altitude is different from that at low altitude, and the high-altitude breakdown voltage corrected using the International Electrotechnical Commission (IEC) altitude correction method is not exactly the same as the actual experimental results.


  • Prediction method of breakdown voltage of long air gaps containing a floating conductor

    by Cheng Xie, Linong Wang, Jiachen Gao, Shaocheng Wu, Bin Song, Lei Liu, Tingting Wang


  • Experimental Investigation of Discharge Path Selectivity of a Long Air Gap Containing a Floating Conductor

    by Cheng Xie, Linong Wang, Jiachen Gao, Yong Peng, Shaocheng Wu, Shuchuang Wu, Wenyu Wang, Jianben Liu, Yan Liu

    Live-line maintenance is an effective means to ensure the reliability of the power system. When linemen float between the high-voltage conductors and the ground potential towers, the discharge characteristics of air gaps are significantly affected. In this article, simplified experiments are carried out to simulate the linemen by a floating conductor. The discharge characteristics of air gaps when the floating conductor is in different positions are studied. An experimental platform with a long air gap containing a floating conductor is used to obtain the breakdown voltage and the discharge path of air gaps under a positive switching impulse. The experimental results show that the existence of a floating electrode affects the air gap breakdown voltage and the discharge path. When the transverse displacement is 80 cm, almost all the discharge paths directly connect the high voltage electrode and plane electrode. Furthermore, the influencing factors of discharge path and breakdown voltage are analyzed, and the fitting equations of breakdown voltage and discharge path probability considering spatial position coordinates are established. Finally, the easy breakdown region considering discharge path is proposed, which provides a theoretical reference for quantitative analysis of the path of linemen entering high potential safely, and to improve the working efficiency of live-line maintenance.