YZYun Zhang

Yun Zhang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yun Zhang has a total of 13 co-authors. Here are the top co-authors by number of shared publications:

  • Yao Mao

    Chinese Academy of Sciences

    6 shared publications
  • Xueqing Wang

    College of Electrical Engineering, Sichuan University, Chengdu, China

    5 shared publications
  • Zheng Wang

    School of Electrical Engineering, Southeast University, Nanjing, China

    5 shared publications
  • Lei Kong

    National Key Laboratory of Optical Field Manipulation Science and Technology, the Key Laboratory of Optical Engineering, Institute of Optics and Electronics, Chinese Academy of Sciences, Chengdu, China

    2 shared publications
  • Ting Zhang

    National Key Laboratory of Optical Field Manipulation Science and Technology, the Key Laboratory of Optical Engineering, and the Institute of Optics and Electronics, Chinese Academy of Sciences, Chengdu, China

    2 shared publications
  • Xinglong Chen

    National Key Laboratory of Optical Field Manipulation Science and Technology, the Key Laboratory of Optical Engineering, Institute of Optics and Electronics, Chinese Academy of Sciences, Chengdu, China

    2 shared publications

Latest Publications

  • Fault Diagnosis and Adaptive Fault-Tolerant Control of Interturn Short-Circuit Fault in PMSM Drives

    by Yun Zhang, Xueqing Wang, Jinjin Peng, Lei Kong, Zheng Wang, Yao Mao

    In this paper, fault diagnosis and adaptive fault-tolerant control (FTC) are proposed for the interturn short-circuit (ITSC) fault in permanent magnet synchronous motor (PMSM) drives. The fault diagnosis is realized by extracting the speed fluctuation caused by the ITSC fault. The dq-axis current injection based adaptive FTC scheme is applied to gradually reduce the speed fluctuation and torque ripple caused by the ITSC fault. The proposed method can achieve excellent fault diagnosis and fault-tolerant (FT) performances without using any machine model or auxiliary circuit. The experiments are conducted to verify the effectiveness of the proposed fault diagnosis and adaptive FTC.


  • Parameter Identification-Based Diagnosis of Open-Circuit Fault in Dual Three-Phase PMSM Drives

    by Ting Zhang, Yao Mao, Yun Zhang, Xinglong Chen, Zheng Wang, Xueqing Wang

    This article proposes a parameter identification-based fault diagnosis method for the open-phase fault (OPF) and open-switch fault (OSF) in open-circuit fault (OCF) of dual three-phase permanent magnet synchronous motor (DTP-PMSM) drives. A six-phase model of DTP-PMSM is developed in the stationary coordinate system. The parameter identification method is utilized to ascertain the resistances of the six-phase windings, facilitating the location of the faulty phase according to resistance variations. Subsequently, the fault type is determined by analyzing the changes in resistance during the positive and negative half-cycles of one fundamental period. With the proposed diagnosis method, the fault type can be identified within one fundamental period. In this way, the proposed method enables precise diagnosis of both OPF and OSF in DTP-PMSM drives. The effectiveness of the proposed diagnosis method is validated through experiments.


  • Fault-Tolerant Control of Common Electrical Faults and Sensor Faults in Sensorless PMSM Drives

    by Yun Zhang, Xueqing Wang, Lei Kong, Linlin Lu, Zheng Wang, Yao Mao

    Conventional sensorless control can hardly estimate the rotor position of faulty drives, which will cause the breakdown of the sensorless permanent-magnet synchronous motor (PMSM) drives in short time. In this article, a fault-tolerant (FT) control scheme is proposed for common electrical faults and sensor faults in the sensorless PMSM drive without using any auxiliary facilities. In the proposed FT control scheme, by simply updating the voltage inputs in the nonlinear flux observer, the rotor position is accurately estimated in open-phase fault (OPF) and open-switch fault (OSF). With the aid of the estimated rotor position, the current references are optimized by considering the tracking error and torque ripple for OSF and OPF. Besides, a Luenberger observer based on stator voltages model is established to estimate the faulty phase current in current sensor fault. The FT control for voltage sensor fault is realized by compensating the measured dc-link voltage. Experimental verification is conducted to prove the validity of the proposed FT control scheme.


  • Open Access

    ESPGD Algorithm to Improve the Convergence Speed for Adaptive Single-Mode Fiber Coupling

    by Jinjin Peng, Bo Qi, Yun Zhang, ZhenChuang Li, Yao Mao

    The adaptive single-mode fiber (SMF) coupling technique is normally adopted since the coupling efficiency (CE) significantly determines the performance of the free-space optical communication (FSOC) systems. The stochastic parallel gradient descent (SPGD) algorithm is the most commonly used control algorithm in adaptive SMF fiber coupling system. This paper proposes an improved SPGD algorithm named estimation-based stochastic parallel gradient descent (ESPGD) algorithm to accelerate the sytem convergence when applied to a practical adaptive SMF coupling system based on fast steering mirror (FSM). Applying the perturbed voltages, FSM dynamic response and then recording the performance metrics is the basic and most time-consuming process in actual adaptive SMF coupling system control. The ESPGD algorithm uses a different gradient estimation method based on adaptive parameter estimation method. The algorithm only needs to perform this process once in one iteration while the original SPGD algorithm needs to perform it twice to obtain the estimated gradient. This greatly reduce the time consumed by one iteration of the algorithm, thereby reducing the convergence time. The simulation and experimental results show that the ESPGD algorithm reduces the system convergence time by nearly half when correcting static angular errors and more than doubles the control bandwidth when correcting sinusoidal angular jitters.


  • Online Current Optimization Based Fault-Tolerant Control of Standard PMSM Drives

    by Yun Zhang, Xinglong Chen, Xueqing Wang, Ting Zhang, Zheng Wang, Yao Mao

    In this article, an online current optimization-based fault-tolerant (FT) control is proposed to improve the FT capability of standard permanent magnet synchronous machine (PMSM) drive with open-phase fault (OPF) and open-switch fault (OSF). In the proposed FT control, the torque ripple, overcurrent endurance, and copper loss are considered to optimize the FT current reference for OPF and OSF. The optimized current reference can be obtained online by calculating the average copper loss in the OPF and OSF FT operation. By using the optimized current reference, the current tracking error can be eliminated, and a good balance between torque ripple and copper loss can be fulfilled. In this way, the torque output capability can be improved after the average copper loss is restricted. The effectiveness of the proposed FT control has been verified by experiments.


  • Current Prediction-Based Fast Diagnosis of Electrical Faults in PMSM Drives

    by Yun Zhang, Yao Mao, Xueqing Wang, Zheng Wang, Dianxun Xiao, Gaoliang Fang

    Open-phase fault (OPF) and open-switch fault (OSF) are two common electrical faults in the permanent magnet synchronous machine (PMSM) drives. To locate the faults rapidly and relieve the fault damage, a current prediction-based diagnosis scheme is proposed for OPF and OSF in three-phase PMSM drives. The proposed diagnosis scheme consists of three steps, namely, determining fault occurrence, locating the faulty phase, and identifying the specific fault. The general current deviations between dq-axis predicted currents from the normal model and dq-axis feedback currents are used to determine the fault occurrence. The general current deviations between dq-axis feedback currents and dq-axis predicted currents from different faulty models are used to locate the faulty phase. Then, an intervention-based diagnosis is developed to identify the specific fault. In this way, the specific fault can be quickly located within several switching periods. Finally, the effectiveness of the proposed diagnosis scheme is verified by the experimental results.