Priyamjeet Deka
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Priyamjeet Deka has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Kalyan Raidongia
Department of Chemistry, Indian Institute of Technology, Guwahati, Assam 781039, India
5 shared publications - Senthilmurugan Subbiah
Department of Chemical Engineering, Indian Institute of Technology Guwahati, Guwahati, Assam 781039, India
4 shared publications Kiran Mayawad
Department of Chemistry, Indian Institute of Technology, Guwahati, Assam 781039, India
3 shared publicationsSonali Roy
Department of Chemistry, Indian Institute of Technology, Guwahati, Assam 781039, India
3 shared publicationsArindom Bikash Neog
Department of Chemistry, Indian Institute of Technology Guwahati, Guwahati, Assam 781039, India
2 shared publicationsBipasha Saikia
Department of Chemistry, Indian Institute of Technology, Guwahati, Assam 781039, India
2 shared publications
Latest Publications
- 17 November 2026
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry A
- Vol. 14 (68) , 46434-46448
Concentration-gradient-induced electrical potential to mitigate solute leakage through 2D materials-based forward osmosis membrane
Harnessing concentration-gradient electricity to simultaneously enhance the permeability and selectivity of permselective forward osmosis membranes.
- 17 November 2026
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry A
- Vol. 14 (68) , 46434-46448
Concentration-gradient-induced electrical potential to mitigate solute leakage through 2D materials-based forward osmosis membrane
Harnessing concentration-gradient electricity to simultaneously enhance the permeability and selectivity of permselective forward osmosis membranes.
- 14 November 2026
- Published by Springer Nature in Emergent Materials
- Vol. 9 (11) , 289
Shear-aligned reduced graphene oxide membranes for enhanced nanofiltration desalination
- 14 November 2026
- Published by Springer Nature in Emergent Materials
- Vol. 9 (11) , 289
Shear-aligned reduced graphene oxide membranes for enhanced nanofiltration desalination
- 11 June 2025
- Published by Royal Society of Chemistry (RSC) in Materials Horizons
- Vol. 12 (17) , 6707-6732
Electrically conductive nanomaterial-enhanced membranes for wastewater reclamation: mechanisms and performance insights
The incorporation of nanomaterials with electrical conductivity into membrane technology is leading to the development of numerous novel strategies towards wastewater reclamation. The probable utility and mechanisms of membrane functionalized with conductive nanomaterials are examined in this critical review. Carbon nanotubes, graphene, and metal oxides are some of the prime examples of conductive nanomaterials that are typically added to improve the permeability, selectivity, and antifouling capabilities of membranes along with imbuing novel functionalities like electrochemical and photocatalytic activities. Functionalization and manufacturing methods, including in situ polymerization, chemical grafting, and physical blending, are covered in this review. The recent literature indicates several noteworthy advancements in this area, such as eliminating microbiological infections, heavy metal ions, organic contaminants, and developing pollutants. The review also discusses economic and environmental factors, highlighting the affordability of these sophisticated membranes and the sustainability of nanomaterial production.
- 11 June 2025
- Published by Royal Society of Chemistry (RSC) in Materials Horizons
- Vol. 12 (17) , 6707-6732
Electrically conductive nanomaterial-enhanced membranes for wastewater reclamation: mechanisms and performance insights
The incorporation of nanomaterials with electrical conductivity into membrane technology is leading to the development of numerous novel strategies towards wastewater reclamation. The probable utility and mechanisms of membrane functionalized with conductive nanomaterials are examined in this critical review. Carbon nanotubes, graphene, and metal oxides are some of the prime examples of conductive nanomaterials that are typically added to improve the permeability, selectivity, and antifouling capabilities of membranes along with imbuing novel functionalities like electrochemical and photocatalytic activities. Functionalization and manufacturing methods, including in situ polymerization, chemical grafting, and physical blending, are covered in this review. The recent literature indicates several noteworthy advancements in this area, such as eliminating microbiological infections, heavy metal ions, organic contaminants, and developing pollutants. The review also discusses economic and environmental factors, highlighting the affordability of these sophisticated membranes and the sustainability of nanomaterial production.
- 22 October 2024
- Published by Wiley in Advanced Functional Materials
- Vol. 35 (4)
Fabrication of Robust Forward Osmosis Membrane by Assembling FeOxCly Nanoparticles
Owing to its inherent advantages like low‐energy consumption, low‐fouling propensity, and high recovering ability over high‐pressure‐driven membrane processes, the future of membrane technology is shifting toward forward osmosis (FO). However, the utility of FO in challenging areas is hindered by the lack of suitable FO membranes. Here, the development of innovative FO membranes by depositing weakly magnetic and positively charged FeOxCly nanoparticles on a negatively charged nylon membrane (FeOx‐Nyl) is reported. Remarkably, the FeOx‐Nyl membrane possesses outstanding stability in an aqueous medium and survived in both acidic (pH = 3.3) and basic (pH = 12.2) solutions. Upon varying the loading amount of FeOxCly, the water flux of the FeOx‐Nyl membrane varies from 27.8 to 61.3 LMH (from 5 to 30 mg). Due to its hydrophilic nature, the FeOx‐Nyl membrane exhibits excellent flux recovery rates (FRR), up to ≈70%. The outstanding robustness and high flux of FeOx‐Nyl are exploited in challenging applications like recovering reactive chemical wastes and dehydration of acetic acid.
- 22 October 2024
- Published by Wiley in Advanced Functional Materials
- Vol. 35 (4)
Fabrication of Robust Forward Osmosis Membrane by Assembling FeOxCly Nanoparticles
Owing to its inherent advantages like low‐energy consumption, low‐fouling propensity, and high recovering ability over high‐pressure‐driven membrane processes, the future of membrane technology is shifting toward forward osmosis (FO). However, the utility of FO in challenging areas is hindered by the lack of suitable FO membranes. Here, the development of innovative FO membranes by depositing weakly magnetic and positively charged FeOxCly nanoparticles on a negatively charged nylon membrane (FeOx‐Nyl) is reported. Remarkably, the FeOx‐Nyl membrane possesses outstanding stability in an aqueous medium and survived in both acidic (pH = 3.3) and basic (pH = 12.2) solutions. Upon varying the loading amount of FeOxCly, the water flux of the FeOx‐Nyl membrane varies from 27.8 to 61.3 LMH (from 5 to 30 mg). Due to its hydrophilic nature, the FeOx‐Nyl membrane exhibits excellent flux recovery rates (FRR), up to ≈70%. The outstanding robustness and high flux of FeOx‐Nyl are exploited in challenging applications like recovering reactive chemical wastes and dehydration of acetic acid.
- 21 December 2023
- Published by Elsevier in Chemical Engineering Journal
- Vol. 480
Biomimetic remote handling and sensing devices of multiwalled carbon nanotubes and vanadium pentoxide
- 21 December 2023
- Published by Elsevier in Chemical Engineering Journal
- Vol. 480
Biomimetic remote handling and sensing devices of multiwalled carbon nanotubes and vanadium pentoxide
- Open Access
Novel Approach to Landfill Wastewater Treatment Fouling Mitigation: Air Gap Membrane Distillation with Tin Sulfide-Coated PTFE Membrane
This study addressed the fouling issue in membrane distillation (M.D.) technology, a promising method for water purification and wastewater reclamation. To enhance the anti-fouling properties of the M.D. membrane, a tin sulfide (TS) coating onto polytetrafluoroethylene (PTFE) was proposed and evaluated with air gap membrane distillation (AGMD) using landfill leachate wastewater at high recovery rates (80% and 90%). The presence of TS on the membrane surface was confirmed using various techniques, such as Field Emission Scanning Electron Microscopy (FE-SEM), Fourier Transform Infrared Spectroscopy (FT-IR), Energy Dispersive Spectroscopy (EDS), contact angle measurement, and porosity analysis. The results indicated the TS-PTFE membrane exhibited better anti-fouling properties than the pristine PTFE membrane, and its fouling factors (FFs) were 10.4–13.1% compared to 14.4–16.5% for the PTFE membrane. The fouling was attributed to pore blockage and cake formation of carbonous and nitrogenous compounds. The study also found that physical cleaning with deionized (DI) water effectively restored the water flux, with more than 97% recovered for the TS-PTFE membrane. Additionally, the TS-PTFE membrane showed better water flux and product quality at 55 °C and excellent stability in maintaining the contact angle over time compared to the PTFE membrane.
Open AccessNovel Approach to Landfill Wastewater Treatment Fouling Mitigation: Air Gap Membrane Distillation with Tin Sulfide-Coated PTFE Membrane
This study addressed the fouling issue in membrane distillation (M.D.) technology, a promising method for water purification and wastewater reclamation. To enhance the anti-fouling properties of the M.D. membrane, a tin sulfide (TS) coating onto polytetrafluoroethylene (PTFE) was proposed and evaluated with air gap membrane distillation (AGMD) using landfill leachate wastewater at high recovery rates (80% and 90%). The presence of TS on the membrane surface was confirmed using various techniques, such as Field Emission Scanning Electron Microscopy (FE-SEM), Fourier Transform Infrared Spectroscopy (FT-IR), Energy Dispersive Spectroscopy (EDS), contact angle measurement, and porosity analysis. The results indicated the TS-PTFE membrane exhibited better anti-fouling properties than the pristine PTFE membrane, and its fouling factors (FFs) were 10.4–13.1% compared to 14.4–16.5% for the PTFE membrane. The fouling was attributed to pore blockage and cake formation of carbonous and nitrogenous compounds. The study also found that physical cleaning with deionized (DI) water effectively restored the water flux, with more than 97% recovered for the TS-PTFE membrane. Additionally, the TS-PTFE membrane showed better water flux and product quality at 55 °C and excellent stability in maintaining the contact angle over time compared to the PTFE membrane.
- Open Access
Fouling and Performance Investigation of Membrane Distillation at Elevated Recoveries for Seawater Desalination and Wastewater Reclamation
This study reports on the impact of elevated recovery (i.e., 80%, 85%, and 90%) on the fouling and performance of air gap membrane distillation (AGMD) with real seawater and landfill leachate wastewater samples using polytetrafluoroethylene (PTFE) polymer membranes. Increasing the feed temperature from 55 °C to 65 °C improved the water flux of seawater and wastewater and shortened the operating time by 42.8% for all recoveries. The average water flux in the 80%, 85%, and 90% recovery experiments at the 65 °C feed temperature was 32%, 37.32%, and 36.7% higher than the case of 55 °C for the same recoveries. The water flux decline was more severe at a higher temperature and recovery. The highest flux decline was observed with a 90% recovery at 65 °C feed temperature, followed by an 85% recovery at 65 °C. Close examination of the foulants layer revealed that seawater formed a cake fouling layer made predominantly of metal oxides. In contrast, the landfill leachate fouling was a combination of pore blocking and cake formation, consisting mainly of carbonous and nitrogenous compounds. Physical cleaning with deionized (DI) water at 55 °C and 65 °C and chemical cleaning with hydrogen peroxide (H2O2) were investigated for their efficiency in removing membrane foulants. Analytical results revealed that seawater fouling caused membrane pore blockage while wastewater fouling formed a porous layer on the membrane surface. The results showed that membrane cleaning with hydrogen peroxide restored >97% of the water flux. Interestingly, the fouling factor in seawater tests was 10%, while it was 16% for the wastewater tests.
Open AccessFouling and Performance Investigation of Membrane Distillation at Elevated Recoveries for Seawater Desalination and Wastewater Reclamation
This study reports on the impact of elevated recovery (i.e., 80%, 85%, and 90%) on the fouling and performance of air gap membrane distillation (AGMD) with real seawater and landfill leachate wastewater samples using polytetrafluoroethylene (PTFE) polymer membranes. Increasing the feed temperature from 55 °C to 65 °C improved the water flux of seawater and wastewater and shortened the operating time by 42.8% for all recoveries. The average water flux in the 80%, 85%, and 90% recovery experiments at the 65 °C feed temperature was 32%, 37.32%, and 36.7% higher than the case of 55 °C for the same recoveries. The water flux decline was more severe at a higher temperature and recovery. The highest flux decline was observed with a 90% recovery at 65 °C feed temperature, followed by an 85% recovery at 65 °C. Close examination of the foulants layer revealed that seawater formed a cake fouling layer made predominantly of metal oxides. In contrast, the landfill leachate fouling was a combination of pore blocking and cake formation, consisting mainly of carbonous and nitrogenous compounds. Physical cleaning with deionized (DI) water at 55 °C and 65 °C and chemical cleaning with hydrogen peroxide (H2O2) were investigated for their efficiency in removing membrane foulants. Analytical results revealed that seawater fouling caused membrane pore blockage while wastewater fouling formed a porous layer on the membrane surface. The results showed that membrane cleaning with hydrogen peroxide restored >97% of the water flux. Interestingly, the fouling factor in seawater tests was 10%, while it was 16% for the wastewater tests.
- 7 August 2022
- Published by Elsevier in Journal of Membrane Science
- Vol. 660, 120884
Performance of novel sericin doped reduced graphene oxide membrane for FO based membrane crystallization application
- 7 August 2022
- Published by Elsevier in Journal of Membrane Science
- Vol. 660, 120884
Performance of novel sericin doped reduced graphene oxide membrane for FO based membrane crystallization application