MCMarie-Anne Chevallier

Marie-Anne Chevallier

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Marie-Anne Chevallier has a total of 34 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Revision of the 21909 standard on passive personal neutron dosemeters

    by Marie-Anne Chevallier, François Quéinnec

    Since 2012, International Standardization Organization TC85/SC2 Working Group 19 dealing with ‘Individual monitoring for external radiations’ has been conducting important work revising the 21909 standard on passive personal neutron dosemeters. A consensus in the community acted that the 2005 version( 1) needed to be revised for two main reasons: (1) to achieve a document applicable to all systems irrespectively to the considered techniques and (2) to reach harmonisation between performance tests and conditions of use at the workplaces. The document was completely rewritten to be binding enough to ensure that any neutron dosimetry system fulfilling the criteria would be reliable in most of the usual work situations, in terms of dose level, energy and direction distributions of the neutron fluence. This paper explains the reasons behind the revision and the new philosophy of the series published in 2021, so that Individual Monitoring Services may better understand how to apply the requirements in practice.


  • Analysis of EURADOS neutron intercomparison results according to new ISO standards criteria

    by M-A Chevallier, E Fantuzzi, M Hajek, S Mayer, R Tanner, D J Thomas, F Vanhavere

    The European Radiation Dosimetry Group has carried out several different types of intercomparison (IC) exercises in the past that qualify as proficiency tests for different dosimetry systems and types of radiation. The first neutron dosemeter IC was held in 2012 (IC2012n) and was followed by a second in 2017/2018 (IC2017n). In sum, 31 Individual Monitoring Services (IMSs) entered 34 dosimetry systems in IC2012n, and 32 IMSs entered 33 dosimetry systems for IC2017n. Such exercises provided a rare opportunity to see how neutron dosemeters perform. For the IC2012n exercise, there were no applicable performance standards for neutron personal dosemeters. ISO/TC85/SC2 updated the ISO Standard 14146 in 2018 (ISO 14146:2018. Radiation protection—Criteria and performance limits for the periodic evaluation of dosimetry services) to include neutron dosimetry. It was thus possible to analyse the IC2017n exercise in accordance with the requirements given by this new standard. It is now of interest to reanalyse the results of IC2012n to quantify any modifications to the conclusions.


  • 25 years of EURADOS working group 2 ‘harmonisation of individual monitoring in Europe’

    by Marie-Anne Chevallier, Oliver Hupe, João Alves, Janwillem van Dijk, David T Bartlett, Elena Fantuzzi, Phil Gilvin, Hannes Stadtmann, Vasiliki Kamenopoulou, Raul M Garcia

    April 2022: The International Conference on Individual Monitoring of Ionising Radiation (IM2022), the first live conference after the COVID pandemic, provided a renewed opportunity to discuss again with colleagues and share new information about individual monitoring, how we solve our common problems by research studies, new methodologies... This desire, this need to share common problems around this theme does not date from yesterday. It was born 25 y ago in Brussels on 28 April 1997, during the first plenary meeting of a concerted EURADOS action called ‘Harmonisation and dosimetric quality assurance in individual monitoring for external radiation’. That event represented the start of a new working group in EURADOS: WG2, which aims to foster harmonisation in individual monitoring for external radiation. EURADOS, in December 1996, set up an Action entitled ‘Harmonisation and Dosimetric Quality Assurance in Individual Monitoring for External Radiation’. The main objectives of this Action were to assist the consolidation within the EU of the quality of individual monitoring using personal dosemeters and to facilitate harmonised procedures. In order to meet these objectives an Action Group was set up, chaired by David Bartlett (NRPB) and comprising members from each of the EU Member States plus Switzerland. Sub-groups were formed to carry out each of three tasks and prepare a report, assisted by all members of the Action Group. The meetings of the EURADOS Action Group were supported by the European Commission, Directorate General XII, Science Research and Development, under the Nuclear Fission Safety—Reactor Safety, Waste Management and Radiation Protection, Framework Programme (FP) 1994–1998, contract number F14P-CT96-0061


  • Open Access

    Neutron personal dosimetry using polyallyl diglycol carbonate (PADC): Current status, best practices and proposed research

    by M. Bolzonella, I. Ambrožová, M. Caresana, N. Gibbens, P. Gilvin, F. Mariotti, A. Savary, A. Stabilini, F.A. Vittoria, E.G. Yukihara, et al.


  • EURADOS IC2012N: FURTHER INFORMATION DERIVED FROM AN EURADOS INTERNATIONAL COMPARISON OF NEUTRON PERSONAL DOSEMETERS

    by M.-A. Chevallier, E. Fantuzzi, R. Cruz-Suarez, M. Luszik-Bhadra, S. Mayer, D. J. Thomas, R. Tanner, F. Vanhavere

    In 2012, the European Radiation Dosimetry Group (EURADOS) performed an intercomparison for neutron dosemeters that are intended to measure personal dose equivalent, Hp(10). A total of 31 participants registered with 34 dosimetry systems. The irradiation tests were chosen to provide the participants with useful information on their dosimetry systems, i.e. linearity, reproducibility, responses for different energies and angles and to simulated workplace fields. This paper gives details of the extensive information derived from the exercise.


  • Risk of eye lens radiation exposure for members of the public

    by M.-A. Chevallier, A. Rannou, C. Villagrasa, I. Clairand

    In 2011, the International Commission on Radiological Protection (ICRP) reviewed its recommendation concerning the equivalent dose limit for the eye lens, lowering it to 20 mSv in a year, for occupational exposure in planned exposure situations. The ICRP's statement does not contain any explicit recommendations regarding the organ dose limit for the eye lens for public exposure. For the moment, no change is proposed. But, to be coherent in the overall approach, the current equivalent limit for the public might be lowered. A similar yardstick than in the former recommendation may be used, that is to say a reduction of 10 times lower than that for occupational exposure. In this context, additional data on potential scenarios for public exposure of the eye lens are necessary. This paper, mainly based on a literature study, aims to provide, as far as possible, an exhaustive list of the situations in which members of the public can be exposed at the level of the eye lens. Once these situations have been defined, some calculations, made to assess the associated doses to the eye lens, are presented. This literature study did not reveal any current situations where members of the public would receive significant radiation doses to the eye lens. Indeed, the situations in which the dose to the eye lens might reach around 1 mSv per year for the public are extremely rare.


  • EURADOS IC2012N: EURADOS 2012 intercomparison for whole-body neutron dosimetry

    by E. Fantuzzi, M.- A. Chevallier, R. Cruz-Suarez, M. Luszik-Bhadra, S. Mayer, D. J. Thomas, R. Tanner, F. Vanhavere

    The European Radiation Dosimetry Group (EURADOS) IC2012n intercomparison for neutron dosemeters intended to measure personal dose equivalent, Hp(10), was performed in 2012. A total of 31 participants (27 individual monitoring services from Europe, 2 from Japan, 1 from Israel and 1 from USA) registered with 34 dosimetry systems. Participation was restricted to passive or active neutron dosemeters routinely used in individual monitoring of radiation workers. The dosimetry systems were based on thermoluminescence, polyallyldiglycol carbonate, optically stimulated luminescence, fission track detection and silicon diodes (electronic devices). The irradiation tests were chosen to provide the participants with useful information on their dosimetry systems, i.e. linearity, reproducibility, responses for different energies and angles and to simulated workplace fields. The paper will report and discuss the first analysis of the results of the EURADOS IC2012n intercomparison.