Murad A. Muradov
Research Subjects
Research Interests
Murad A. Muradov has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Alexander Nikolaevich Ryakhovsky
Central Research Institute of Dentistry and Maxillofacial Surgery
2 shared publications - Vladislav Alekseevich Erokhin
Samara State Medical University
2 shared publications - A.A. Karapetyan
Research Institute of Dental and Maxillofacial Surgery
1 shared publication A.N. Ryahovsky
Research Institute of Dental and Maxillofacial Surgery
1 shared publication- Dmitrii A. Trunin
Samara State Medical University
1 shared publication - V.A. Chkalin
Research Institute of Dental and Maxillofacial Surgery
1 shared publication
Latest Publications
- Open Access
- 1 March 2025
- Published by ECO-Vector LLC in Russian Journal of Dentistry
- Vol. 29 (1) , 55-62
Method for measuring and correcting the fit of fixed dental prostheses
BACKGROUND: One of the key indicators of the quality of fixed prostheses is their precise fit to the prosthetic bed. Errors occurring at clinical and laboratory stages during prosthesis fabrication often lead to variations in the degree of fit of the final prosthesis. Most existing methods for evaluating prosthesis fit are primarily of scientific interest and have not gained widespread clinical application due to their complexity and inconvenience in practical use. AIM: To improve the effectiveness of prosthetic treatment by enhancing the fit of fixed dental prostheses. MATERIALS AND METHODS: The fit of completed prostheses was assessed using a silicone test and a specialized device — a calibrator — which enables the clinician to quickly and accurately measure the thickness of the silicone film. RESULTS: It was found that all prostheses received from the dental laboratory exhibited varying degrees of fit. The measured values ranged from 20 to 200 µm, with 50% of the prostheses exceeding 100 µm. Adjustments made to crowns using the proposed method improved their fit by an average of 59.28%. CONCLUSION: The proposed clinical method for assessing and correcting the marginal fit of fixed dental prostheses allows clinicians to monitor this parameter effectively and achieve clinically acceptable values.
- 1 March 2025
- Published by ECO-Vector LLC in Russian Journal of Dentistry
- Vol. 29 (1) , 55-62
Open AccessMethod for measuring and correcting the fit of fixed dental prostheses
BACKGROUND: One of the key indicators of the quality of fixed prostheses is their precise fit to the prosthetic bed. Errors occurring at clinical and laboratory stages during prosthesis fabrication often lead to variations in the degree of fit of the final prosthesis. Most existing methods for evaluating prosthesis fit are primarily of scientific interest and have not gained widespread clinical application due to their complexity and inconvenience in practical use. AIM: To improve the effectiveness of prosthetic treatment by enhancing the fit of fixed dental prostheses. MATERIALS AND METHODS: The fit of completed prostheses was assessed using a silicone test and a specialized device — a calibrator — which enables the clinician to quickly and accurately measure the thickness of the silicone film. RESULTS: It was found that all prostheses received from the dental laboratory exhibited varying degrees of fit. The measured values ranged from 20 to 200 µm, with 50% of the prostheses exceeding 100 µm. Adjustments made to crowns using the proposed method improved their fit by an average of 59.28%. CONCLUSION: The proposed clinical method for assessing and correcting the marginal fit of fixed dental prostheses allows clinicians to monitor this parameter effectively and achieve clinically acceptable values.
- 23 April 2024
- Published by Media Sphere Publishing Group in Stomatologiya
- Vol. 103 (3) , 26-30
Study on the pressure on ceramic veneers during cementation
Objective. The aim of the study is measuring the magnitude and determining the method of finger pressure exerted by doctors on ceramic veneers during their fixation. Material and methods. A simulation model was designed in order to measure the volume of finger pressure. Veneers were produced for 2 central incisors. Doctors alternately placed veneers on the model and applied pressure on them for 20 seconds simulating the clinical stage of cementing. The operator recorded the maximum readings of the scales and entered the result on the research protocol. In addition, it was recorded which finger the doctor exerts on the veneer during its cementing to ensure a tight fit: thumb or index finger. Results. The values obtained during cementation of 54% doctors ranged up to 1 kg, 27% of doctors from 1 to 2 kg and only 19% more than 2 kg. 80% of doctors applied the main pressure on the veneer using their thumb, while the pressure force was 1.4 kg. For those doctors who pressed the veneer to the tooth with their index finger, the impact value was 0.8 kg. Conclusion. The finger pressure on the veneer during cementation applied by dentists varies, the average pressure on the veneers was about 1.5 kg. The amount of pressure on cement during laboratory tests of cements for fixing veneers differs from clinical values many times. The development of a veneers fixation protocol, taking into account the conducted research, will ensure a reliable and accurate fit of the veneer at the stage of its cementing.
- 23 April 2024
- Published by Media Sphere Publishing Group in Stomatologiya
- Vol. 103 (3) , 26-30
Study on the pressure on ceramic veneers during cementation
Objective. The aim of the study is measuring the magnitude and determining the method of finger pressure exerted by doctors on ceramic veneers during their fixation. Material and methods. A simulation model was designed in order to measure the volume of finger pressure. Veneers were produced for 2 central incisors. Doctors alternately placed veneers on the model and applied pressure on them for 20 seconds simulating the clinical stage of cementing. The operator recorded the maximum readings of the scales and entered the result on the research protocol. In addition, it was recorded which finger the doctor exerts on the veneer during its cementing to ensure a tight fit: thumb or index finger. Results. The values obtained during cementation of 54% doctors ranged up to 1 kg, 27% of doctors from 1 to 2 kg and only 19% more than 2 kg. 80% of doctors applied the main pressure on the veneer using their thumb, while the pressure force was 1.4 kg. For those doctors who pressed the veneer to the tooth with their index finger, the impact value was 0.8 kg. Conclusion. The finger pressure on the veneer during cementation applied by dentists varies, the average pressure on the veneers was about 1.5 kg. The amount of pressure on cement during laboratory tests of cements for fixing veneers differs from clinical values many times. The development of a veneers fixation protocol, taking into account the conducted research, will ensure a reliable and accurate fit of the veneer at the stage of its cementing.
- 1 January 2022
- Published by Media Sphere Publishing Group in Stomatologiya
- Vol. 101 (4) , 53-60
Lower jaw virtual reposition accuracy research
The aim is to study of the accuracy of the virtual reposition of the mandible (LF) by comparing the virtual and real position of the LF heads, as well as the analysis of factors contributing to the occurrence of errors. An experimental model of a human skull with a movable LF was made of radiopaque material. The resulting computed tomogram (CT) of the upper and lower jaws and temporomandibular joint (TMJ) was combined with dental scans of dental rows and CT scans and a report on the position of the heads of the LF was obtained. Then the LF was shifted to another position and this position was fixed. Optical bite recorders were obtained using an intraoral scanner. An experimental model with a fixed new position of the LF was placed in a tomograph and repeated CT was obtained. In the program, according to optical registers, a virtual reposition of the LF was carried out. The correspondence of the virtual and real position of the mandibular heads was compared. The absolute difference of glenoid fossa space between the actual and virtual reconstruction was 0.542±0.3354 mm in the anterior joint section (M±δ, M - average mean, δ - standard deviation); for the upper joint section - 0.309±0.2246 mm; and 0.260±0.1862 mm for the posterior section. The integral indicator of surface coincidence (q) when the virtual and actual position are directly compared was 0.296±0.1254 (s.u.). The total margin of error depends on the following factors: repeated scanning error (teeth arches and bite scans), repeated CBCT error, a combination of scan and CBCT error, a combination of teeth arch scan and bite scan error, error of TMJ separation. The latter two factors were the most significant.
- 1 January 2022
- Published by Media Sphere Publishing Group in Stomatologiya
- Vol. 101 (4) , 53-60
Lower jaw virtual reposition accuracy research
The aim is to study of the accuracy of the virtual reposition of the mandible (LF) by comparing the virtual and real position of the LF heads, as well as the analysis of factors contributing to the occurrence of errors. An experimental model of a human skull with a movable LF was made of radiopaque material. The resulting computed tomogram (CT) of the upper and lower jaws and temporomandibular joint (TMJ) was combined with dental scans of dental rows and CT scans and a report on the position of the heads of the LF was obtained. Then the LF was shifted to another position and this position was fixed. Optical bite recorders were obtained using an intraoral scanner. An experimental model with a fixed new position of the LF was placed in a tomograph and repeated CT was obtained. In the program, according to optical registers, a virtual reposition of the LF was carried out. The correspondence of the virtual and real position of the mandibular heads was compared. The absolute difference of glenoid fossa space between the actual and virtual reconstruction was 0.542±0.3354 mm in the anterior joint section (M±δ, M - average mean, δ - standard deviation); for the upper joint section - 0.309±0.2246 mm; and 0.260±0.1862 mm for the posterior section. The integral indicator of surface coincidence (q) when the virtual and actual position are directly compared was 0.296±0.1254 (s.u.). The total margin of error depends on the following factors: repeated scanning error (teeth arches and bite scans), repeated CBCT error, a combination of scan and CBCT error, a combination of teeth arch scan and bite scan error, error of TMJ separation. The latter two factors were the most significant.