Xinnian Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Xinnian Li has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Qinghua Li
Research Center of Space Control and Inertial Technology, Harbin Institute of Technology, Harbin, China
5 shared publications - Ao Shen
Research Center of Space Control and Inertial Technology, Harbin Institute of Technology, Harbin, China
2 shared publications - Changhong Wang
Space Control and Inertial Technology Research Center, Harbin Institute of Technology, Harbin, China
2 shared publications - Hao Wang
Research Center of Space Control and Inertial Technology, Harbin Institute of Technology, Harbin, China
2 shared publications - Jingyang Sun
Research Center of Space Control and Inertial Technology, Harbin Institute of Technology, Harbin, China
2 shared publications - Qingshuang Zeng
Harbin Institute of Technology
2 shared publications
Latest Publications
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Internet of Things Journal
- Vol. 13 (21) , 50883-50894
Cooperative Target Localization Method Based on IMM-MEE-EKF
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Internet of Things Journal
- Vol. 13 (21) , 50883-50894
Cooperative Target Localization Method Based on IMM-MEE-EKF
- Open Access
- 20 October 2026
- Published by Elsevier in SSRN Electronic Journal
A Centroid-Referenced Single-Scale Model with Jacobian Equilibration for Iterative MAGCOM
This paper shows that its dual-scale affine model suffers from two defects. The anisotropic scale parameter mixes a stretch component into the rotation sensitivity, and under a locally uniform gradient its sensitivity column lies in the span of the isotropic-scale and rotation columns, so the anisotropic scale parameter is locally unidentifiable. The proposed DP-IMAGCOM therefore adopts a centroid-referenced single-scale model, whose isotropic scale removes the anisotropic scale parameter and whose centroid origin cancels the constant-gradient coupling term; Jacobian column equilibration then scales each column by its $L_2$ norm, counteracting column-magnitude imbalance and its condition-number inflation, and permits a stopping threshold referenced to the a priori standard deviation of geomagnetic measurement error. Across 100 Monte Carlo trials at each of three noise levels it attains pooled RMSE values of 83.88 m at 2 nT and 107.80 m at 5 nT, while a fixed-wing flight segment gives RMSE 87.57 m after 32 iterations.- 20 October 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessA Centroid-Referenced Single-Scale Model with Jacobian Equilibration for Iterative MAGCOM
This paper shows that its dual-scale affine model suffers from two defects. The anisotropic scale parameter mixes a stretch component into the rotation sensitivity, and under a locally uniform gradient its sensitivity column lies in the span of the isotropic-scale and rotation columns, so the anisotropic scale parameter is locally unidentifiable. The proposed DP-IMAGCOM therefore adopts a centroid-referenced single-scale model, whose isotropic scale removes the anisotropic scale parameter and whose centroid origin cancels the constant-gradient coupling term; Jacobian column equilibration then scales each column by its $L_2$ norm, counteracting column-magnitude imbalance and its condition-number inflation, and permits a stopping threshold referenced to the a priori standard deviation of geomagnetic measurement error. Across 100 Monte Carlo trials at each of three noise levels it attains pooled RMSE values of 83.88 m at 2 nT and 107.80 m at 5 nT, while a fixed-wing flight segment gives RMSE 87.57 m after 32 iterations. - 4 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-10
An Ellipse-Fitting Positioning Method Based on Ultralow-Frequency Magnetic Field-Based Positioning Systems
This paper presents a novel positioning method based on ultra-low-frequency magnetic field-based positioning systems (ULF-MPSs) in non-line-of-sight (NLOS) environments. The system for easy deployment is implemented with the rotating permanent magnet, two three-axis magnetometers and a three-axis accelerometer. Due to the high penetration and absence of accumulated errors, ULF-MPSs have emerged as a research point for precise positioning in NLOS environments. However, it is challenging for ULF-MPSs to achieve rapid and accurate positioning of the target, with its performance significantly influenced by attitude errors in both the magnetic source and sensors relative to the global coordinate system. In this paper, an ellipse-fitting method is proposed to estimate the position of the target rapidly, derived from the elliptical relationship among the components of magnetic flux density. A two-step method is developed to enhance the robustness of the proposed positioning method against the attitude errors. The realized system exhibits the mean and maximum relative errors of less than 1.17% and 2.82% respectively in the presence of attitude errors in both magnetic source and sensors within a 15 m × 15 m woodland area. Similar performance is obtained in a 10 m × 5 m underground environment. Additionally, the method’s high computational efficiency offers significant advantages in terms of real-time performance.
- 4 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-10
An Ellipse-Fitting Positioning Method Based on Ultralow-Frequency Magnetic Field-Based Positioning Systems
This paper presents a novel positioning method based on ultra-low-frequency magnetic field-based positioning systems (ULF-MPSs) in non-line-of-sight (NLOS) environments. The system for easy deployment is implemented with the rotating permanent magnet, two three-axis magnetometers and a three-axis accelerometer. Due to the high penetration and absence of accumulated errors, ULF-MPSs have emerged as a research point for precise positioning in NLOS environments. However, it is challenging for ULF-MPSs to achieve rapid and accurate positioning of the target, with its performance significantly influenced by attitude errors in both the magnetic source and sensors relative to the global coordinate system. In this paper, an ellipse-fitting method is proposed to estimate the position of the target rapidly, derived from the elliptical relationship among the components of magnetic flux density. A two-step method is developed to enhance the robustness of the proposed positioning method against the attitude errors. The realized system exhibits the mean and maximum relative errors of less than 1.17% and 2.82% respectively in the presence of attitude errors in both magnetic source and sensors within a 15 m × 15 m woodland area. Similar performance is obtained in a 10 m × 5 m underground environment. Additionally, the method’s high computational efficiency offers significant advantages in terms of real-time performance.
- 29 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-9
A Rotating Permanent Magnets Positioning System for Laying Underground Pipelines
This study presents a novel system for accurately positioning underground pipelines by applying rotating permanent magnets, addressing the limitations of traditional wireless systems in effectively penetrating both the pipe and surrounding soil. The system is realized with the improved fingerprint matching algorithm, which is composed of a rotating structure, a permanent magnet, a magnetic sensor, an A/D module, and a positioning solution module. Under the boundary conditions, a continuous propagation model of the magnetic field is analyzed for the medium of different magnetic permeability, which is the basis of the positioning method in the pipelines. To solve the problem of difficulty in obtaining an accurate dense database, a methodology involving measurement and virtual reference points is developed. A matching method based on cluster analysis is applied in the system to improve the matching efficiency, which includes cluster selection, coarse matching, and fine positioning. The realized prototype is used to verify the proposed approach in long metal pipelines, which have a maximum positioning error of less than 0.15m, a mean value of 0.0974m, and a standard deviation of 0.0106m in a factory environment. This affirms the effectiveness of the developed system in addressing issues related to accurate pipeline localization.
- 29 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-9
A Rotating Permanent Magnets Positioning System for Laying Underground Pipelines
This study presents a novel system for accurately positioning underground pipelines by applying rotating permanent magnets, addressing the limitations of traditional wireless systems in effectively penetrating both the pipe and surrounding soil. The system is realized with the improved fingerprint matching algorithm, which is composed of a rotating structure, a permanent magnet, a magnetic sensor, an A/D module, and a positioning solution module. Under the boundary conditions, a continuous propagation model of the magnetic field is analyzed for the medium of different magnetic permeability, which is the basis of the positioning method in the pipelines. To solve the problem of difficulty in obtaining an accurate dense database, a methodology involving measurement and virtual reference points is developed. A matching method based on cluster analysis is applied in the system to improve the matching efficiency, which includes cluster selection, coarse matching, and fine positioning. The realized prototype is used to verify the proposed approach in long metal pipelines, which have a maximum positioning error of less than 0.15m, a mean value of 0.0974m, and a standard deviation of 0.0106m in a factory environment. This affirms the effectiveness of the developed system in addressing issues related to accurate pipeline localization.
- 8 August 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-10
An Inertial Magneto-Inductive Positioning System Based on GWO-PF Algorithm
This article describes the technology and realization of an inertial magneto-inductive positioning system (MPS) with the improved GWO-PF algorithm. The system is implemented with a dual-axis magnetic beacon (MB), a three-axis magnetic sensor, and an inertial measurement unit (IMU). Unfortunately, the performance of the magnetic-based PSs is severely impaired by the attitude errors of the magnetic sensor that is directly obtained from IMU. In this article, a positioning method of inertial magneto-inductive is presented to solve the above problem, which is not affected by the attitude errors of the sensors. Furthermore, a particle filter (PF) based on the improved grey wolf optimizer (GWO-PF) algorithm is developed to improve the positioning performance proposed of the moving target. The realized prototype exhibits a maximum positioning error lower than 0.15 m for the static target in an indoor environment with a medium area of 8.4 m $\times $ 6.5 m. The performance of tracking moving target is verified by simulation and the cumulative probability distribution (CPD) indicates that 99% of positioning errors are lower than 0.83 m.
- 8 August 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-10
An Inertial Magneto-Inductive Positioning System Based on GWO-PF Algorithm
This article describes the technology and realization of an inertial magneto-inductive positioning system (MPS) with the improved GWO-PF algorithm. The system is implemented with a dual-axis magnetic beacon (MB), a three-axis magnetic sensor, and an inertial measurement unit (IMU). Unfortunately, the performance of the magnetic-based PSs is severely impaired by the attitude errors of the magnetic sensor that is directly obtained from IMU. In this article, a positioning method of inertial magneto-inductive is presented to solve the above problem, which is not affected by the attitude errors of the sensors. Furthermore, a particle filter (PF) based on the improved grey wolf optimizer (GWO-PF) algorithm is developed to improve the positioning performance proposed of the moving target. The realized prototype exhibits a maximum positioning error lower than 0.15 m for the static target in an indoor environment with a medium area of 8.4 m $\times $ 6.5 m. The performance of tracking moving target is verified by simulation and the cumulative probability distribution (CPD) indicates that 99% of positioning errors are lower than 0.83 m.