Shruthi Raghavendra
Research Subjects
Shruthi Raghavendra has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Chin-Tuan Tan
Department of Electrical and Computer Engineering, The University of Texas at Dallas, Richardson, TX 75080, USA
2 shared publications - Jaya Eripilla
Independent Researcher
2 shared publications - Ram Ghadiyaram
Independent Researcher
2 shared publications - Sungmin Lee
Department of Speech-Language Pathology and Aural rehabilitation Tongmyong University Busan Korea
2 shared publications Brett A. Martin
Department of Electrical and Computer Engineering, University of Texas at Dallas, Richardson, TX, United States
1 shared publicationChin-Tuan Tan
Department of Electrical and Computer Engineering, University of Texas at Dallas, Richardson, TX, United States
1 shared publication
Latest Publications
- 3 June 2026
- Published by Springer Nature
- p. 394-405
Audio Analysis of the Gayatri Mantra: A Novel AI/ML Study with Cultural Insights
- 3 June 2026
- Published by Springer Nature
- p. 394-405
Audio Analysis of the Gayatri Mantra: A Novel AI/ML Study with Cultural Insights
- Open Access
- 6 December 2025
- Published by MDPI AG in Journal of Otorhinolaryngology, Hearing and Balance Medicine
- Vol. 6 (2) , 24
Pupillometry as an Objective Measure of Auditory Perception and Listening Effort Across the Lifespan: A Review
Background/Objectives: This narrative review aims to evaluate the use of pupillometry as an objective measure of auditory perception and listening effort across the lifespan. Specifically, it synthesizes research examining pupillary responses in individuals with and without hearing impairment across pediatric, adult, and older adult populations. The review addresses methodological practices and clinical implications for integrating pupillometry into routine audiological assessment. Methods: 12 peer-reviewed studies published between 2010 and 2025 were selected through a systematic search of databases including PubMed, Scopus, Web of Science, and Google Scholar. Inclusion criteria required empirical use of pupillometry in auditory tasks involving human participants with normal hearing or hearing impairment. Studies were analyzed for population characteristics, experimental paradigms, pupillometric metrics (e.g., peak pupil dilation), level of evidence, and relevance to clinical audiology. This article uses a narrative review approach to organize and interpret findings. Results: Across age groups and hearing conditions, pupillometry consistently demonstrated sensitivity to cognitive load and listening effort, particularly in noisy environments or during complex auditory tasks. Pediatric studies revealed its potential as a non-invasive tool for preverbal children. Adult and older adult studies confirmed that pupillary responses reflect device performance (e.g., hearing aids, cochlear implants) and cognitive–linguistic demands. Methodological variability and individual differences in pupil response patterns were noted as limitations. Conclusions: The findings support the use of pupillometry as a valuable adjunct to behavioral audiometry, offering objective insight into auditory–cognitive load. Its application holds promise for pediatric diagnostics, hearing technology evaluation, and geriatric audiology. Standardization of measurement protocols and development of normative data are necessary to enhance clinical applicability and generalizability.
- 6 December 2025
- Published by MDPI AG in Journal of Otorhinolaryngology, Hearing and Balance Medicine
- Vol. 6 (2) , 24
Open AccessPupillometry as an Objective Measure of Auditory Perception and Listening Effort Across the Lifespan: A Review
Background/Objectives: This narrative review aims to evaluate the use of pupillometry as an objective measure of auditory perception and listening effort across the lifespan. Specifically, it synthesizes research examining pupillary responses in individuals with and without hearing impairment across pediatric, adult, and older adult populations. The review addresses methodological practices and clinical implications for integrating pupillometry into routine audiological assessment. Methods: 12 peer-reviewed studies published between 2010 and 2025 were selected through a systematic search of databases including PubMed, Scopus, Web of Science, and Google Scholar. Inclusion criteria required empirical use of pupillometry in auditory tasks involving human participants with normal hearing or hearing impairment. Studies were analyzed for population characteristics, experimental paradigms, pupillometric metrics (e.g., peak pupil dilation), level of evidence, and relevance to clinical audiology. This article uses a narrative review approach to organize and interpret findings. Results: Across age groups and hearing conditions, pupillometry consistently demonstrated sensitivity to cognitive load and listening effort, particularly in noisy environments or during complex auditory tasks. Pediatric studies revealed its potential as a non-invasive tool for preverbal children. Adult and older adult studies confirmed that pupillary responses reflect device performance (e.g., hearing aids, cochlear implants) and cognitive–linguistic demands. Methodological variability and individual differences in pupil response patterns were noted as limitations. Conclusions: The findings support the use of pupillometry as a valuable adjunct to behavioral audiometry, offering objective insight into auditory–cognitive load. Its application holds promise for pediatric diagnostics, hearing technology evaluation, and geriatric audiology. Standardization of measurement protocols and development of normative data are necessary to enhance clinical applicability and generalizability.
- Open Access
- 18 November 2025
- Published by MDPI AG in Audiology Research
- Vol. 15 (6) , 158
Classification of Speech and Associated EEG Responses from Normal-Hearing and Cochlear Implant Talkers Using Support Vector Machines
Background/Objectives: Speech produced by individuals with hearing loss differs notably from that of normal-hearing (NH) individuals. Although cochlear implants (CIs) provide sufficient auditory input to support speech acquisition and control, there remains considerable variability in speech intelligibility among CI users. As a result, speech produced by CI talkers often exhibits distinct acoustic characteristics compared to that of NH individuals. Methods: Speech data were obtained from eight cochlear-implant (CI) and eight normal-hearing (NH) talkers, while electroencephalogram (EEG) responses were recorded from 11 NH listeners exposed to the same speech stimuli. Support Vector Machine (SVM) classifiers employing 3-fold cross-validation were evaluated using classification accuracy as the performance metric. This study evaluated the efficacy of Support Vector Machine (SVM) algorithms using four kernel functions (Linear, Polynomial, Gaussian, and Radial Basis Function) to classify speech produced by NH and CI talkers. Six acoustic features—Log Energy, Zero-Crossing Rate (ZCR), Pitch, Linear Predictive Coefficients (LPC), Mel-Frequency Cepstral Coefficients (MFCCs), and Perceptual Linear Predictive Cepstral Coefficients (PLP-CC)—were extracted. These same features were also extracted from electroencephalogram (EEG) recordings of NH listeners who were exposed to the speech stimuli. The EEG analysis leveraged the assumption of quasi-stationarity over short time windows. Results: Classification of speech signals using SVMs yielded the highest accuracies of 100% and 94% for the Energy and MFCC features, respectively, using Gaussian and RBF kernels. EEG responses to speech achieved classification accuracies exceeding 70% for ZCR and Pitch features using the same kernels. Other features such as LPC and PLP-CC yielded moderate to low classification performance. Conclusions: The results indicate that both speech-derived and EEG-derived features can effectively differentiate between CI and NH talkers. Among the tested kernels, Gaussian and RBF provided superior performance, particularly when using Energy and MFCC features. These findings support the application of SVMs for multimodal classification in hearing research, with potential applications in improving CI speech processing and auditory rehabilitation.
- 18 November 2025
- Published by MDPI AG in Audiology Research
- Vol. 15 (6) , 158
Open AccessClassification of Speech and Associated EEG Responses from Normal-Hearing and Cochlear Implant Talkers Using Support Vector Machines
Background/Objectives: Speech produced by individuals with hearing loss differs notably from that of normal-hearing (NH) individuals. Although cochlear implants (CIs) provide sufficient auditory input to support speech acquisition and control, there remains considerable variability in speech intelligibility among CI users. As a result, speech produced by CI talkers often exhibits distinct acoustic characteristics compared to that of NH individuals. Methods: Speech data were obtained from eight cochlear-implant (CI) and eight normal-hearing (NH) talkers, while electroencephalogram (EEG) responses were recorded from 11 NH listeners exposed to the same speech stimuli. Support Vector Machine (SVM) classifiers employing 3-fold cross-validation were evaluated using classification accuracy as the performance metric. This study evaluated the efficacy of Support Vector Machine (SVM) algorithms using four kernel functions (Linear, Polynomial, Gaussian, and Radial Basis Function) to classify speech produced by NH and CI talkers. Six acoustic features—Log Energy, Zero-Crossing Rate (ZCR), Pitch, Linear Predictive Coefficients (LPC), Mel-Frequency Cepstral Coefficients (MFCCs), and Perceptual Linear Predictive Cepstral Coefficients (PLP-CC)—were extracted. These same features were also extracted from electroencephalogram (EEG) recordings of NH listeners who were exposed to the speech stimuli. The EEG analysis leveraged the assumption of quasi-stationarity over short time windows. Results: Classification of speech signals using SVMs yielded the highest accuracies of 100% and 94% for the Energy and MFCC features, respectively, using Gaussian and RBF kernels. EEG responses to speech achieved classification accuracies exceeding 70% for ZCR and Pitch features using the same kernels. Other features such as LPC and PLP-CC yielded moderate to low classification performance. Conclusions: The results indicate that both speech-derived and EEG-derived features can effectively differentiate between CI and NH talkers. Among the tested kernels, Gaussian and RBF provided superior performance, particularly when using Energy and MFCC features. These findings support the application of SVMs for multimodal classification in hearing research, with potential applications in improving CI speech processing and auditory rehabilitation.
- Open Access
- 13 November 2025
- Published by MDPI AG in Preprints.org
Pupillometry as an Objective Measure of Auditory Perception and Listening Effort Across the Lifespan: A Review
Background/Objectives: This narrative review aims to evaluate the use of pupillometry as an objective measure of auditory perception and listening effort across the lifespan. Specifically, it synthesizes research examining pupillary responses in indi-viduals with and without hearing impairment across pediatric, adult, and older adult populations. The review addresses methodological practices and clinical implications for integrating pupillometry into routine audiological assessment. Methods: Eleven peer-reviewed studies published between 2010 and 2025 were selected through a sys-tematic search of databases including PubMed, Scopus, Web of Science, and Google Scholar. Inclusion criteria required empirical use of pupillometry in auditory tasks in-volving human participants with normal hearing or hearing impairment. Studies were analyzed for population characteristics, experimental paradigms, pupillometric metrics (e.g., peak pupil dilation), level of evidence, and relevance to clinical audiology. This article uses a narrative review approach to organize and interpret findings. Results: Across age groups and hearing conditions, pupillometry consistently demonstrated sensitivity to cognitive load and listening effort, particularly in noisy environments or during complex auditory tasks. Pediatric studies revealed its potential as a non-invasive tool for preverbal children. Adult and older adult studies confirmed that pupillary re-sponses reflect device performance (e.g., hearing aids, cochlear implants) and cogni-tive-linguistic demands. Methodological variability and individual differences in pupil response patterns were noted as limitations. Conclusions: The findings support the use of pupillometry as a valuable adjunct to behavioral audiometry, offering objective insight into auditory-cognitive load. Its application holds promise for pediatric diagnostics, hearing technology evaluation, and geriatric audiology. Standardization of measurement protocols and development of normative data are necessary to enhance clinical applica-bility and generalizability.
- 13 November 2025
- Published by MDPI AG in Preprints.org
Open AccessPupillometry as an Objective Measure of Auditory Perception and Listening Effort Across the Lifespan: A Review
Background/Objectives: This narrative review aims to evaluate the use of pupillometry as an objective measure of auditory perception and listening effort across the lifespan. Specifically, it synthesizes research examining pupillary responses in indi-viduals with and without hearing impairment across pediatric, adult, and older adult populations. The review addresses methodological practices and clinical implications for integrating pupillometry into routine audiological assessment. Methods: Eleven peer-reviewed studies published between 2010 and 2025 were selected through a sys-tematic search of databases including PubMed, Scopus, Web of Science, and Google Scholar. Inclusion criteria required empirical use of pupillometry in auditory tasks in-volving human participants with normal hearing or hearing impairment. Studies were analyzed for population characteristics, experimental paradigms, pupillometric metrics (e.g., peak pupil dilation), level of evidence, and relevance to clinical audiology. This article uses a narrative review approach to organize and interpret findings. Results: Across age groups and hearing conditions, pupillometry consistently demonstrated sensitivity to cognitive load and listening effort, particularly in noisy environments or during complex auditory tasks. Pediatric studies revealed its potential as a non-invasive tool for preverbal children. Adult and older adult studies confirmed that pupillary re-sponses reflect device performance (e.g., hearing aids, cochlear implants) and cogni-tive-linguistic demands. Methodological variability and individual differences in pupil response patterns were noted as limitations. Conclusions: The findings support the use of pupillometry as a valuable adjunct to behavioral audiometry, offering objective insight into auditory-cognitive load. Its application holds promise for pediatric diagnostics, hearing technology evaluation, and geriatric audiology. Standardization of measurement protocols and development of normative data are necessary to enhance clinical applica-bility and generalizability.
- Open Access
- 13 November 2025
- Published by MDPI AG in Preprints.org
Classification of Speech And Associated Eeg Responses from Normal-Hearing and Cochlear Implant Talkers Using Support Vector Machines
Background/Objectives : Speech produced by individuals with hearing loss differs notably from that of normal-hearing (NH) individuals. Although cochlear implants (CIs) provide sufficient auditory input to support speech acquisition and control, there remains considerable variability in speech intelligibility among CI users. As a result, speech produced by CI talkers often exhibits distinct acoustic characteristics compared to that of NH individuals. Methods: Speech data were obtained from 8 cochlear-implant (CI) and 8 normal-hearing (NH) talkers, while EEG responses were recorded from 11 NH listeners exposed to the same speech stimuli. Support Vector Machine (SVM) classifiers employing 3-fold cross-validation were evaluated using classification accuracy as the performance metric. This study evaluated the efficacy of Support Vector Machine (SVM) algorithms using four kernel functions (Linear, Polynomial, Gaussian, and Radial Basis Function) to classify speech produced by NH and CI talkers. Six acoustic features—Log Energy, Zero-Crossing Rate (ZCR), Pitch, Linear Predictive Coefficients (LPC), Mel-Frequency Cepstral Coefficients (MFCCs), and Perceptual Linear Predictive Cepstral Coefficients (PLP-CC)—were extracted. These same features were also extracted from electroencephalogram (EEG) recordings of NH listeners who were exposed to the speech stimuli. The EEG analysis leveraged the assumption of quasi-stationarity over short time windows. Results: Classification of speech signals using SVMs yielded the highest accuracies of 100% and 94% for the Energy and MFCC features, respectively, using Gaussian and RBF kernels. EEG responses to speech achieved classification accuracies exceeding 70% for ZCR and Pitch features using the same kernels. Other features such as LPC and PLP-CC yielded moderate to low classification performance. Conclusions: The results indicate that both speech-derived and EEG-derived features can effectively differentiate between CI and NH talkers. Among the tested kernels, Gaussian and RBF provided superior performance, particularly when using Energy and MFCC features. These findings support the application of SVMs for multimodal classification in hearing research, with potential applications in improving CI speech processing and auditory rehabilitation.
- 13 November 2025
- Published by MDPI AG in Preprints.org
Open AccessClassification of Speech And Associated Eeg Responses from Normal-Hearing and Cochlear Implant Talkers Using Support Vector Machines
Background/Objectives : Speech produced by individuals with hearing loss differs notably from that of normal-hearing (NH) individuals. Although cochlear implants (CIs) provide sufficient auditory input to support speech acquisition and control, there remains considerable variability in speech intelligibility among CI users. As a result, speech produced by CI talkers often exhibits distinct acoustic characteristics compared to that of NH individuals. Methods: Speech data were obtained from 8 cochlear-implant (CI) and 8 normal-hearing (NH) talkers, while EEG responses were recorded from 11 NH listeners exposed to the same speech stimuli. Support Vector Machine (SVM) classifiers employing 3-fold cross-validation were evaluated using classification accuracy as the performance metric. This study evaluated the efficacy of Support Vector Machine (SVM) algorithms using four kernel functions (Linear, Polynomial, Gaussian, and Radial Basis Function) to classify speech produced by NH and CI talkers. Six acoustic features—Log Energy, Zero-Crossing Rate (ZCR), Pitch, Linear Predictive Coefficients (LPC), Mel-Frequency Cepstral Coefficients (MFCCs), and Perceptual Linear Predictive Cepstral Coefficients (PLP-CC)—were extracted. These same features were also extracted from electroencephalogram (EEG) recordings of NH listeners who were exposed to the speech stimuli. The EEG analysis leveraged the assumption of quasi-stationarity over short time windows. Results: Classification of speech signals using SVMs yielded the highest accuracies of 100% and 94% for the Energy and MFCC features, respectively, using Gaussian and RBF kernels. EEG responses to speech achieved classification accuracies exceeding 70% for ZCR and Pitch features using the same kernels. Other features such as LPC and PLP-CC yielded moderate to low classification performance. Conclusions: The results indicate that both speech-derived and EEG-derived features can effectively differentiate between CI and NH talkers. Among the tested kernels, Gaussian and RBF provided superior performance, particularly when using Energy and MFCC features. These findings support the application of SVMs for multimodal classification in hearing research, with potential applications in improving CI speech processing and auditory rehabilitation.
- 3 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-9
Enhancing Wireless Sensor Network Security with Quantum-Enabled Elliptic Curve Cryptography
Wireless sensor networks (WSNs) are systems made up of sensor nodes that communicate wirelessly over short distances, with adaptability and functionality at their coreessence. These networks have traits. Face challenges in devising effective strategies for identifying and thwarting attacks due to limitations, in individual sensor node processing power and the essence of wireless communication. Securing WSN poses a challenge given the constrained processing abilities of sensor nodes and the inherent nature of communication while facing various security threats that have emerged alongside the widespread adoption of these networks. To protect against these dangers it's crucial to put in place the security measures Encryption's key, to keeping data safe from unauthorized users Nevertheless not all encryption methods are equally strong as some are vulnerable Elliptic Curve Cryptography (ECC) is considered the best option due to its smaller key sizes offering strong security with efficiency in space and energy As technology advances conventional encryption techniques are seen as inadequate, for ensuring data privacy and security Utilizing principles from physics to ensure data transmission, between the sender and receiver is a groundbreaking advancement in network security known as quantum cryptography. Quantum Key Distribution (QKD) combined with ECC is highlighted in this study, for authentication processes, key management and energy efficiency. A novel method called QKD ECC has been put into practice. Compared against ECC and other encryption methods to bolster the security of WSN and safeguard the confidentiality of data exchange.
- 3 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-9
Enhancing Wireless Sensor Network Security with Quantum-Enabled Elliptic Curve Cryptography
Wireless sensor networks (WSNs) are systems made up of sensor nodes that communicate wirelessly over short distances, with adaptability and functionality at their coreessence. These networks have traits. Face challenges in devising effective strategies for identifying and thwarting attacks due to limitations, in individual sensor node processing power and the essence of wireless communication. Securing WSN poses a challenge given the constrained processing abilities of sensor nodes and the inherent nature of communication while facing various security threats that have emerged alongside the widespread adoption of these networks. To protect against these dangers it's crucial to put in place the security measures Encryption's key, to keeping data safe from unauthorized users Nevertheless not all encryption methods are equally strong as some are vulnerable Elliptic Curve Cryptography (ECC) is considered the best option due to its smaller key sizes offering strong security with efficiency in space and energy As technology advances conventional encryption techniques are seen as inadequate, for ensuring data privacy and security Utilizing principles from physics to ensure data transmission, between the sender and receiver is a groundbreaking advancement in network security known as quantum cryptography. Quantum Key Distribution (QKD) combined with ECC is highlighted in this study, for authentication processes, key management and energy efficiency. A novel method called QKD ECC has been put into practice. Compared against ECC and other encryption methods to bolster the security of WSN and safeguard the confidentiality of data exchange.
- Open Access
- 9 August 2022
- Published by Frontiers Media SA in Frontiers in Neuroscience
- Vol. 16, 927872
Cortical entrainment to speech produced by cochlear implant talkers and normal-hearing talkers
Cochlear implants (CIs) are commonly used to restore the ability to hear in those with severe or profound hearing loss. CIs provide the necessary auditory feedback for them to monitor and control speech production. However, the speech produced by CI users may not be fully restored to achieve similar perceived sound quality to that produced by normal-hearing talkers and this difference is easily noticeable in their daily conversation. In this study, we attempt to address this difference as perceived by normal-hearing listeners, when listening to continuous speech produced by CI talkers and normal-hearing talkers. We used a regenerative model to decode and reconstruct the speech envelope from the single-trial electroencephalogram (EEG) recorded on the scalp of the normal-hearing listeners. Bootstrap Spearman correlation between the actual speech envelope and the envelope reconstructed from the EEG was computed as a metric to quantify the difference in response to the speech produced by the two talker groups. The same listeners were asked to rate the perceived sound quality of the speech produced by the two talker groups as a behavioral sound quality assessment. The results show that both the perceived sound quality ratings and the computed metric, which can be seen as the degree of cortical entrainment to the actual speech envelope across the normal-hearing listeners, were higher in value for speech produced by normal hearing talkers than that for CI talkers. The first purpose of the study was to determine how well the envelope of speech is represented neurophysiologically via its similarity to the envelope reconstructed from EEG. The second purpose was to show how well this representation of speech for both CI and normal hearing talker groups differentiates in term of perceived sound quality.
- 9 August 2022
- Published by Frontiers Media SA in Frontiers in Neuroscience
- Vol. 16, 927872
Open AccessCortical entrainment to speech produced by cochlear implant talkers and normal-hearing talkers
Cochlear implants (CIs) are commonly used to restore the ability to hear in those with severe or profound hearing loss. CIs provide the necessary auditory feedback for them to monitor and control speech production. However, the speech produced by CI users may not be fully restored to achieve similar perceived sound quality to that produced by normal-hearing talkers and this difference is easily noticeable in their daily conversation. In this study, we attempt to address this difference as perceived by normal-hearing listeners, when listening to continuous speech produced by CI talkers and normal-hearing talkers. We used a regenerative model to decode and reconstruct the speech envelope from the single-trial electroencephalogram (EEG) recorded on the scalp of the normal-hearing listeners. Bootstrap Spearman correlation between the actual speech envelope and the envelope reconstructed from the EEG was computed as a metric to quantify the difference in response to the speech produced by the two talker groups. The same listeners were asked to rate the perceived sound quality of the speech produced by the two talker groups as a behavioral sound quality assessment. The results show that both the perceived sound quality ratings and the computed metric, which can be seen as the degree of cortical entrainment to the actual speech envelope across the normal-hearing listeners, were higher in value for speech produced by normal hearing talkers than that for CI talkers. The first purpose of the study was to determine how well the envelope of speech is represented neurophysiologically via its similarity to the envelope reconstructed from EEG. The second purpose was to show how well this representation of speech for both CI and normal hearing talker groups differentiates in term of perceived sound quality.