SLStuart R. Leadley

Stuart R. Leadley

*This is an algorithmically generated author record based on publicly available information.

Stuart R. Leadley has a total of 4 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Introduction to reproducible laboratory hard x-ray photoelectron spectroscopy

    by Kateryna Artyushkova, Stuart R. Leadley, Alexander G. Shard

    X-ray sources with a photon energy higher than 2140 eV are increasingly being used for routine x-ray photoelectron spectroscopy (XPS) on laboratory-based instruments. This analytical approach is termed “HAXPES” (hard x-ray photoelectron spectroscopy). This article provides an overview of the current and potential future uses of laboratory-based HAXPES in comparison to routine XPS performed using Al Kα and Mg Kα x-ray sources. The standardization of XPS has occurred over 30 years and many of the procedures and reference works are specific to the use of Al Kα and Mg Kα x-ray sources. In this article, we discuss the translation of standard XPS practices to HAXPES, indicate useful resources for HAXPES users, and highlight areas where there is a need for improved information and guidance.


  • Quantification of aluminium and silicon‐containing materials using Ag Lα X‐rays

    by Stuart R. Leadley

    In recent years, instrument manufacturers have been providing laboratory‐based HAXPES (hard X‐ray photoelectron spectroscopy) instruments that have monochromated silver Lα, chromium Kα and gallium Kα X‐ray sources. To be more than a qualitative tool, two things are required: calibration of the signal intensity as a function of kinetic energy (spectrometer response function) and relative sensitivity factors. This is now possible because of routines being available to generate the spectrometer response functions for dual Al Kα/Ag Lα X‐ray sources and the availability of Cant average matrix relative sensitivity factors (AMRSFs). However, to improve accuracy when using the Cant AMRSF care needs to be taken in the definition of the peak areas being used. This is because they need to include the total intrinsic signal that often extends beyond the main peak. This is a particular challenge when quantifying using the Al 1s peak generated with Ag Lα X‐rays as some of the intrinsic signal overlaps with the Al KLL Auger peak. When materials include both aluminium and silicon atoms, the Si 2s and 2p peaks sit upon extended signals coming from the Al 2s and 2s peaks, respectively. Thus, quantification should be limited to using the main peak area, which necessitates different relative sensitivity factors (RSFs). Using polydimethylsiloxane (PDMS) and sapphire (Al 2 O 3 ) as model systems, experimental RSFs have been determined for use with the main peaks for O 1s, Al 1s, Al2s Al 2p, Si 1s, Si 2s and Si 2p subshells normalized to the RSF of the carbon 1s main peak.


  • Applying monochromated silver X‐rays to the surface characterization of silicon‐containing materials

    by Stuart R. Leadley, Michael B. Clark, Mayank Jhalaria

    Although the use of a monochromated silver X‐ray source for X‐ray photoelectron spectroscopy (XPS) analysis was first reported in the 1980s, it has found limited application. Two important advances have been made in recent years that now enable it to be used more routinely for surface analysis. These advancements are the development of relative sensitivity factors for quantification and the fully motorized dual silver/aluminum X‐ray source, which enables the change to monochromated X‐ray energies in a few minutes versus hours. Silicones are an important class of materials that have unique chemical properties that can vary from liquids to glass‐like materials. XPS, with monochromatic Al Kα X‐rays, is used routinely to characterize silicon‐containing materials and to identify different silicone functional groups. This was aided by the work published on the analysis of Si 2p peaks acquired from polysiloxane materials. The binding energy increases nonlinearly when methyl groups on a silicon atom are replaced by oxygen atoms. This work will now be extended to determine the binding energy shifts in Si 1s, 2s, and Auger spectra, which will allow the identification of silicon chemistry when using monochromated silver X‐rays. The Auger parameters of the different polysiloxanes will be compared to those of other silicon‐containing materials. Comparison of the depth of analysis in silicon‐containing materials when changing from aluminum to silver X‐rays will also be addressed.