Jingxuan Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jingxuan Wang has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Peter Martinus Adranius van Ooijen
University of Groningen, University Medical Center Groningen, Department of Radiation Oncology, Groningen, the Netherlands
6 shared publications Rozemarijn Vliegenthart
Department of Radiology, University of Groningen, University Medical Center of Groningen, Groningen, The Netherlands
4 shared publicationsMarcel van Tuinen
Department of Radiology, University of Groningen, University Medical Center of Groningen, Groningen, The Netherlands
2 shared publicationsNikos Sourlos
Department of Radiology, University of Groningen, University Medical Center of Groningen, Groningen, The Netherlands
2 shared publications- Nikos Sourlos
University Medical Center Groningen (UMCG)
2 shared publications - Rozemarijn Vliegenthart
Department of Radiology, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands
2 shared publications
Latest Publications
- Open Access
- 27 June 2025
- Published by Springer Nature in Insights into Imaging
- Vol. 16 (1) , 1-10
A multi-view CNN model to predict resolving of new lung nodules on follow-up low-dose chest CT
Objective: New, intermediate-sized nodules in lung cancer screening undergo follow-up CT, but some of these will resolve. We evaluated the performance of a multi-view convolutional neural network (CNN) in distinguishing resolving and non-resolving new, intermediate-sized lung nodules. Materials and methods: This retrospective study utilized data on 344 intermediate-sized nodules (50–500 mm3) in 250 participants from the NELSON (Dutch-Belgian Randomized Lung Cancer Screening) trial. We implemented four-fold cross-validation for model training and testing. A multi-view CNN model was developed by combining three two-dimensional (2D) CNN models and one three-dimensional (3D) CNN model. We used 2D, 2.5D, and 3D models for comparison. The models’ performance was evaluated using sensitivity, specificity, and area under the ROC curve (AUC). Specificity, indicating what percentage of non-resolving nodules requiring follow-up can be correctly predicted, was maximized. Results: Among all nodules, 18.3% (63) were resolving. The multi-view CNN model achieved an AUC of 0.81, with a mean sensitivity of 0.63 (SD, 0.15) and a mean specificity of 0.93 (SD, 0.02). The model significantly improved performance compared to 2D, 2.5D, or 3D models (p < 0.05). Under the premise of specificity greater than 90% (meaning < 10% of non-resolving nodules are incorrectly identified as resolving), follow-up CT in 14% of individuals could be prevented. Conclusion: The multi-view CNN model achieved high specificity in discriminating new intermediate nodules that would need follow-up CT by identifying non-resolving nodules. After further validation and optimization, this model may assist with decision-making when new intermediate nodules are found in lung cancer screening. Critical relevance statement: The multi-view CNN-based model has the potential to reduce unnecessary follow-up scans when new nodules are detected, aiding radiologists in making earlier, more informed decisions. Key Points: Predicting the resolution of new intermediate lung nodules in lung cancer screening CT is a challenge. Our multi-view CNN model showed an AUC of 0.81, a specificity of 0.93, and a sensitivity of 0.63 at the nodule level. The multi-view model demonstrated a significant improvement in AUC compared to the three 2D models, one 2.5D model, and one 3D model. Graphical
- 27 June 2025
- Published by Springer Nature in Insights into Imaging
- Vol. 16 (1) , 1-10
Open AccessA multi-view CNN model to predict resolving of new lung nodules on follow-up low-dose chest CT
Objective: New, intermediate-sized nodules in lung cancer screening undergo follow-up CT, but some of these will resolve. We evaluated the performance of a multi-view convolutional neural network (CNN) in distinguishing resolving and non-resolving new, intermediate-sized lung nodules. Materials and methods: This retrospective study utilized data on 344 intermediate-sized nodules (50–500 mm3) in 250 participants from the NELSON (Dutch-Belgian Randomized Lung Cancer Screening) trial. We implemented four-fold cross-validation for model training and testing. A multi-view CNN model was developed by combining three two-dimensional (2D) CNN models and one three-dimensional (3D) CNN model. We used 2D, 2.5D, and 3D models for comparison. The models’ performance was evaluated using sensitivity, specificity, and area under the ROC curve (AUC). Specificity, indicating what percentage of non-resolving nodules requiring follow-up can be correctly predicted, was maximized. Results: Among all nodules, 18.3% (63) were resolving. The multi-view CNN model achieved an AUC of 0.81, with a mean sensitivity of 0.63 (SD, 0.15) and a mean specificity of 0.93 (SD, 0.02). The model significantly improved performance compared to 2D, 2.5D, or 3D models (p < 0.05). Under the premise of specificity greater than 90% (meaning < 10% of non-resolving nodules are incorrectly identified as resolving), follow-up CT in 14% of individuals could be prevented. Conclusion: The multi-view CNN model achieved high specificity in discriminating new intermediate nodules that would need follow-up CT by identifying non-resolving nodules. After further validation and optimization, this model may assist with decision-making when new intermediate nodules are found in lung cancer screening. Critical relevance statement: The multi-view CNN-based model has the potential to reduce unnecessary follow-up scans when new nodules are detected, aiding radiologists in making earlier, more informed decisions. Key Points: Predicting the resolution of new intermediate lung nodules in lung cancer screening CT is a challenge. Our multi-view CNN model showed an AUC of 0.81, a specificity of 0.93, and a sensitivity of 0.63 at the nodule level. The multi-view model demonstrated a significant improvement in AUC compared to the three 2D models, one 2.5D model, and one 3D model. Graphical
- Open Access
- 11 April 2025
- Published by Elsevier in Computerized Medical Imaging and Graphics
- Vol. 123, 102553
A comparison of an integrated and image-only deep learning model for predicting the disappearance of indeterminate pulmonary nodules
- 11 April 2025
- Published by Elsevier in Computerized Medical Imaging and Graphics
- Vol. 123, 102553
Open AccessA comparison of an integrated and image-only deep learning model for predicting the disappearance of indeterminate pulmonary nodules
- Open Access
- 22 December 2023
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 169, 107871
Explainable machine learning model based on clinical factors for predicting the disappearance of indeterminate pulmonary nodules
- 22 December 2023
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 169, 107871
Open AccessExplainable machine learning model based on clinical factors for predicting the disappearance of indeterminate pulmonary nodules
- 29 August 2023
- Published by Morressier GmbH
Predicting the disappearance of indeterminate pulmonary nodules on CT scans based on CNN
Background Lung nodules are a common finding on computed tomography (CT) scans. The indeterminate pulmonary nodules (IPN) may disappear | POSTER
- 29 August 2023
- Published by Morressier GmbH
Predicting the disappearance of indeterminate pulmonary nodules on CT scans based on CNN
Background Lung nodules are a common finding on computed tomography (CT) scans. The indeterminate pulmonary nodules (IPN) may disappear | POSTER
- 20 September 2022
- Published by Morressier GmbH
Possible bias in supervised deep learning algorithms for CT lung nodule detection and classification
Artificial Intelligence (AI) algorithms for automatic lung nodule detection and classification can assist radiologists in their daily routine of |
- 20 September 2022
- Published by Morressier GmbH
Possible bias in supervised deep learning algorithms for CT lung nodule detection and classification
Artificial Intelligence (AI) algorithms for automatic lung nodule detection and classification can assist radiologists in their daily routine of |
- Open Access
Possible Bias in Supervised Deep Learning Algorithms for CT Lung Nodule Detection and Classification
Artificial Intelligence (AI) algorithms for automatic lung nodule detection and classification can assist radiologists in their daily routine of chest CT evaluation. Even though many AI algorithms for these tasks have already been developed, their implementation in the clinical workflow is still largely lacking. Apart from the significant number of false-positive findings, one of the reasons for that is the bias that these algorithms may contain. In this review, different types of biases that may exist in chest CT AI nodule detection and classification algorithms are listed and discussed. Examples from the literature in which each type of bias occurs are presented, along with ways to mitigate these biases. Different types of biases can occur in chest CT AI algorithms for lung nodule detection and classification. Mitigation of them can be very difficult, if not impossible to achieve completely.
Open AccessPossible Bias in Supervised Deep Learning Algorithms for CT Lung Nodule Detection and Classification
Artificial Intelligence (AI) algorithms for automatic lung nodule detection and classification can assist radiologists in their daily routine of chest CT evaluation. Even though many AI algorithms for these tasks have already been developed, their implementation in the clinical workflow is still largely lacking. Apart from the significant number of false-positive findings, one of the reasons for that is the bias that these algorithms may contain. In this review, different types of biases that may exist in chest CT AI nodule detection and classification algorithms are listed and discussed. Examples from the literature in which each type of bias occurs are presented, along with ways to mitigate these biases. Different types of biases can occur in chest CT AI algorithms for lung nodule detection and classification. Mitigation of them can be very difficult, if not impossible to achieve completely.