Bingyu Gao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Bingyu Gao has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
Ye Zhao
Nu Instruments, Unit 74 Clywedog Road South Wrexham Industrial Estate, Wrexham LL13 9XS, UK
5 shared publications- Jing Wang
Chinese Acad Sci, Inst Geol & Geophys, Key Lab Mineral Resources, Beijing 100029, Peoples R China
4 shared publications - Ben-Xun Su
State Key Laboratory of Lithospheric and Environmental Coevolution, Institute of Geology and Geophysics, Chinese Academy of Sciences, Beijing 100029, China
3 shared publications Wen-Jun Li
Key Laboratory of Mineral Resources, Institute of Geology and Geophysics, Chinese Academy of Sciences, Beijing 100029, China
3 shared publicationsBenxun Su
Key Laboratory of Mineral Resources, Institute of Geology and Geophysics, Chinese Academy of Sciences, Beijing 100029, China
2 shared publicationsDong-Mei Tang
Key Laboratory of Mineral Resources, Institute of Geology and Geophysics, Chinese Academy of Sciences, Beijing 100029, China
2 shared publications
Latest Publications
- 23 January 2023
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 38 (3) , 603-608
Experimental investigation of improved tolerance for concentration mismatch in potassium isotope analysis on a hexapole collision cell MC-ICP-MS (Nu Sapphire)
Effect of K concentration mismatch up to 30% on δ41K value from RF Ref. of 1.05 V.
- 23 January 2023
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 38 (3) , 603-608
Experimental investigation of improved tolerance for concentration mismatch in potassium isotope analysis on a hexapole collision cell MC-ICP-MS (Nu Sapphire)
Effect of K concentration mismatch up to 30% on δ41K value from RF Ref. of 1.05 V.
- 17 January 2023
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 38 (3) , 656-666
High-precision lithium isotopic analysis using the Nu Sapphire MC-ICP-MS
With single-column chemical purification, highly accurate δ 7 Li values for eight international reference materials are presented together with seventeen Chinese geological reference materials from NRCG using the Nu Sapphire.
- 17 January 2023
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 38 (3) , 656-666
High-precision lithium isotopic analysis using the Nu Sapphire MC-ICP-MS
With single-column chemical purification, highly accurate δ 7 Li values for eight international reference materials are presented together with seventeen Chinese geological reference materials from NRCG using the Nu Sapphire.
- 3 October 2022
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 37 (12) , 2589-2598
High-precision copper isotopic analysis using a Nu Sapphire MC-ICP-MS
Here we present an analytical method for Cu isotopic measurement using standard-sample bracketing on a Nu Sapphire multi-collector inductively coupled plasma mass spectrometer. The effects of Cu concentration and HNO3 molarity mismatch between the standard and the sample, as well as the presence of matrix elements have been evaluated. Intermediate precision of better than ±0.030‰ for δ65Cu (2SD) was routinely obtained on NIST SRM 3114 and NWU-Cu-A. Accurate measurements were achieved when CNa/CCu < 0.5, CTi/CCu, CFe/CCu and CCo/CCu < 1, CNi/CCu < 3 and CZn/CCu < 10. High-precision Cu isotopic data were determined for nineteen geological reference materials, including igneous rocks, sedimentary rocks, metamorphic rocks and chalcopyrite, with an overall range of ∼0.44‰ (−0.056‰ to 0.384‰), nearly 15 times the current analytical precision. The Cu isotopic data of these reference materials can be used for future interlaboratory comparisons.
- 3 October 2022
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 37 (12) , 2589-2598
High-precision copper isotopic analysis using a Nu Sapphire MC-ICP-MS
Here we present an analytical method for Cu isotopic measurement using standard-sample bracketing on a Nu Sapphire multi-collector inductively coupled plasma mass spectrometer. The effects of Cu concentration and HNO3 molarity mismatch between the standard and the sample, as well as the presence of matrix elements have been evaluated. Intermediate precision of better than ±0.030‰ for δ65Cu (2SD) was routinely obtained on NIST SRM 3114 and NWU-Cu-A. Accurate measurements were achieved when CNa/CCu < 0.5, CTi/CCu, CFe/CCu and CCo/CCu < 1, CNi/CCu < 3 and CZn/CCu < 10. High-precision Cu isotopic data were determined for nineteen geological reference materials, including igneous rocks, sedimentary rocks, metamorphic rocks and chalcopyrite, with an overall range of ∼0.44‰ (−0.056‰ to 0.384‰), nearly 15 times the current analytical precision. The Cu isotopic data of these reference materials can be used for future interlaboratory comparisons.
- 21 September 2022
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 37 (10) , 2111-2121
High-precision analysis of calcium isotopes using a Nu Sapphire collision cell (CC)-MC-ICP-MS
This study presents high-precision analyses of calcium (Ca) isotope ratios using a collision-cell multi-collector inductively coupled plasma mass spectrometer (CC-MC-ICP-MS, Nu Sapphire). This instrument allows Ca isotope measurement in the low resolution mode, requiring much less sample compared with TIMS and conventional MC-ICP-MS, and has additional measurement capability of both radiogenic (ε40Ca) and stable isotope ratios (δ44/40Ca and δ44/42Ca). The effects of several factors on the precision and accuracy of Ca isotopic data were evaluated, including the total Ca concentration, Ca intensity mismatch between the sample and standard, HNO3 molarity mismatch between the sample and standard, and the presence of matrix elements. High precision was obtained on 100 ng g−1 Ca samples (i.e., for 6 replicates ∼600 ng of Ca). Accurate measurements require the following conditions: (1) Ca intensities matched within 3% between the sample and standard, (2) low contents of Sr, Mg and Cr (Sr/Ca, Mg/Ca and Cr/Ca ratios need to be lower than 0.01%, and K/Ca, Al/Ca, Ti/Ca and Cr/Ca ratios δ44/40Ca and higher than 0.05‰ (2 SD) for δ44/42Ca. The slope of the fractionation line between δ44/40Ca and δ44/42Ca is 1.9616 ± 0.0794, within the error of the slope value from the exponential law.
- 21 September 2022
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 37 (10) , 2111-2121
High-precision analysis of calcium isotopes using a Nu Sapphire collision cell (CC)-MC-ICP-MS
This study presents high-precision analyses of calcium (Ca) isotope ratios using a collision-cell multi-collector inductively coupled plasma mass spectrometer (CC-MC-ICP-MS, Nu Sapphire). This instrument allows Ca isotope measurement in the low resolution mode, requiring much less sample compared with TIMS and conventional MC-ICP-MS, and has additional measurement capability of both radiogenic (ε40Ca) and stable isotope ratios (δ44/40Ca and δ44/42Ca). The effects of several factors on the precision and accuracy of Ca isotopic data were evaluated, including the total Ca concentration, Ca intensity mismatch between the sample and standard, HNO3 molarity mismatch between the sample and standard, and the presence of matrix elements. High precision was obtained on 100 ng g−1 Ca samples (i.e., for 6 replicates ∼600 ng of Ca). Accurate measurements require the following conditions: (1) Ca intensities matched within 3% between the sample and standard, (2) low contents of Sr, Mg and Cr (Sr/Ca, Mg/Ca and Cr/Ca ratios need to be lower than 0.01%, and K/Ca, Al/Ca, Ti/Ca and Cr/Ca ratios δ44/40Ca and higher than 0.05‰ (2 SD) for δ44/42Ca. The slope of the fractionation line between δ44/40Ca and δ44/42Ca is 1.9616 ± 0.0794, within the error of the slope value from the exponential law.
- 30 July 2022
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 37 (9) , 1869-1875
High-precision iron isotopic measurements in low resolution using collision cell (CC)-MC-ICP-MS
Here we present an analytical method for Fe isotopic measurements in low resolution mode, using a Nu Sapphire collision cell-equipped multi-collector inductively coupled plasma mass spectrometer by standard-sample bracketing. High Fe sensitivity was obtained through reducing Ar based interference by over 9 orders of magnitude whilst other analytes remained unaffected. The effects of Fe concentration, Fe beam intensity and HNO3 molarity mismatch between the standard and sample and the presence of matrix elements have been evaluated. The long-term analyses of JMC Fe and BCR-2 indicate that the obtained isotopic ratios are highly reproducible, with precisions of better than ±0.03‰ for δ56Fe (2SD). Such accurate and precise data could be acquired via 3 to 6 repeat measurements consuming 50–100 ng Fe, which has improved by a factor 40 compared to those previously reported on other instruments. Accurate measurements were achieved by closely matching Fe intensities between the sample and standard (a 5% mismatch would create a 0.02‰ offset in the 56Fe/54Fe ratio). On the other hand, the ratio of the concentration between the matrix elements and Fe, such as CNa/CFe, CMg/CFe, CCa/CFe, CTi/CFe and CNi/CFe, should be kept under 0.1, CK/CFe under 0.3, CAl/CFe and CCu/CFe under 1, and CCo/CFe and CZn/CFe under 2 to avoid any matrix effect. In addition, high precision Fe isotopic data were obtained on twenty-one geological reference materials and were highly consistent with the literature values. Furthermore, we obtained δ56Fe of standard chalcopyrite (XTC) for the first time: 0.127 ± 0.027‰ (2SD, n = 3).
- 30 July 2022
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 37 (9) , 1869-1875
High-precision iron isotopic measurements in low resolution using collision cell (CC)-MC-ICP-MS
Here we present an analytical method for Fe isotopic measurements in low resolution mode, using a Nu Sapphire collision cell-equipped multi-collector inductively coupled plasma mass spectrometer by standard-sample bracketing. High Fe sensitivity was obtained through reducing Ar based interference by over 9 orders of magnitude whilst other analytes remained unaffected. The effects of Fe concentration, Fe beam intensity and HNO3 molarity mismatch between the standard and sample and the presence of matrix elements have been evaluated. The long-term analyses of JMC Fe and BCR-2 indicate that the obtained isotopic ratios are highly reproducible, with precisions of better than ±0.03‰ for δ56Fe (2SD). Such accurate and precise data could be acquired via 3 to 6 repeat measurements consuming 50–100 ng Fe, which has improved by a factor 40 compared to those previously reported on other instruments. Accurate measurements were achieved by closely matching Fe intensities between the sample and standard (a 5% mismatch would create a 0.02‰ offset in the 56Fe/54Fe ratio). On the other hand, the ratio of the concentration between the matrix elements and Fe, such as CNa/CFe, CMg/CFe, CCa/CFe, CTi/CFe and CNi/CFe, should be kept under 0.1, CK/CFe under 0.3, CAl/CFe and CCu/CFe under 1, and CCo/CFe and CZn/CFe under 2 to avoid any matrix effect. In addition, high precision Fe isotopic data were obtained on twenty-one geological reference materials and were highly consistent with the literature values. Furthermore, we obtained δ56Fe of standard chalcopyrite (XTC) for the first time: 0.127 ± 0.027‰ (2SD, n = 3).
- Open Access
- 8 September 2020
- Published by MDPI AG in Applied Sciences
- Vol. 10 (18) , 6218
The Implications of HClO4 for Dissolving Large Masses of Low Level Os in Metal Sulfides and Factors that Influence Re-Os Dating
In general, no more than 1 g of metal sulfide can be completely digested in 20 mL of inverse aqua regia using the Carius tube technique. In this study, the sample weight increased after adding HClO4 to inverse aqua regia while the volume of acid concurrently decreased significantly. Three grams of metal sulfide were digested in 12 mL of acid (3 mL of HClO4 and 9 mL of inverse aqua regia) via the HClO4-inverse aqua regia method. The results using molybdenite reference materials JDC and HLP mixed with 3 g of pyrite were consistent with certified values. Compared to the traditional method, the HClO4-inverse aqua regia method could dissolve a larger sample mass (3 g) with a smaller volume of acids (12 mL). We simultaneously found that the oxidation of digestion acids greatly affected the Os signal but had no influence on the equilibrium of isotope exchange between 185Re and 190Os spikes in Re and Os samples. Remarkably, the heating temperature was the most significant factor influencing the equilibrium of isotope exchange, and the Os in a sample was not equilibrated with the spike until the heating temperature reached 190 °C.
- 8 September 2020
- Published by MDPI AG in Applied Sciences
- Vol. 10 (18) , 6218
Open AccessThe Implications of HClO4 for Dissolving Large Masses of Low Level Os in Metal Sulfides and Factors that Influence Re-Os Dating
In general, no more than 1 g of metal sulfide can be completely digested in 20 mL of inverse aqua regia using the Carius tube technique. In this study, the sample weight increased after adding HClO4 to inverse aqua regia while the volume of acid concurrently decreased significantly. Three grams of metal sulfide were digested in 12 mL of acid (3 mL of HClO4 and 9 mL of inverse aqua regia) via the HClO4-inverse aqua regia method. The results using molybdenite reference materials JDC and HLP mixed with 3 g of pyrite were consistent with certified values. Compared to the traditional method, the HClO4-inverse aqua regia method could dissolve a larger sample mass (3 g) with a smaller volume of acids (12 mL). We simultaneously found that the oxidation of digestion acids greatly affected the Os signal but had no influence on the equilibrium of isotope exchange between 185Re and 190Os spikes in Re and Os samples. Remarkably, the heating temperature was the most significant factor influencing the equilibrium of isotope exchange, and the Os in a sample was not equilibrated with the spike until the heating temperature reached 190 °C.
- 4 November 2015
- Published by Springer Nature in International Journal of Earth Sciences
- Vol. 105 (2) , 507-519
Geochronology and geochemistry of the Badaguan porphyry Cu–Mo deposit in Derbugan metallogenic belt of the NE China, and their geological significances
- 4 November 2015
- Published by Springer Nature in International Journal of Earth Sciences
- Vol. 105 (2) , 507-519
Geochronology and geochemistry of the Badaguan porphyry Cu–Mo deposit in Derbugan metallogenic belt of the NE China, and their geological significances