Zhigang Gao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Zhigang Gao has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Hailiang Chen
Yanshan University
6 shared publications - Shuguang Li
Yanshan University
2 shared publications Bangjian Wang
Xi’an University of Science and Technology
1 shared publicationBiao Wu
1 shared publicationChaoyi Liu
1 shared publicationChun Wang
State Key Laboratory of Metastable Materials Science and Technology and the Key Laboratory for Microstructural Material Physics of Hebei Province, School of Science, Yanshan University, Qinhuangdao, China
1 shared publication
Latest Publications
- 5 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-7
Label-Free In Situ Detection of DNA Hybridization Based on Long-Range Surface Plasmon Resonance in Microstructured Optical Fiber
Deoxyribonucleic acid (DNA), which is considered to be the gene code relating to some serious diseases such as breast cancer, lymph cancer, leukemia, intestinal cancer and lung cancer, is difficult to detect due to its low concentration in the early stage of diseases. In this paper, we propose a composite film of Au/MgF2 coated pomelo-type microstructured optical fiber (MOF) to detect the low concentration DNA. The dielectric film of MgF2 helped to enhance the penetration depth of surface plasmon polaritons and to achieve the long-range surface plasmon resonance (LRSPR) which was utilized to detect the micron-size molecule of DNA. The composite film-coated MOF immersed in mercaptoethylamine (MEA) solution to aminate and then functionalized with COOH-modified probe DNA (pDNA) to fabricate the sensing probe. Experimental results showed that the fabricated sensing probe was sensitive to the target DNA (tDNA) with an ultra-low concentration of 2 μ M, but insensitive to the non-target DNA (nonDNA). The proposed sensor, showing the merits of label-free, in-situ, real-time, specificity, stability, and high sensitivity, could be a competitive candidate in DNA detection.
- 5 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-7
Label-Free In Situ Detection of DNA Hybridization Based on Long-Range Surface Plasmon Resonance in Microstructured Optical Fiber
Deoxyribonucleic acid (DNA), which is considered to be the gene code relating to some serious diseases such as breast cancer, lymph cancer, leukemia, intestinal cancer and lung cancer, is difficult to detect due to its low concentration in the early stage of diseases. In this paper, we propose a composite film of Au/MgF2 coated pomelo-type microstructured optical fiber (MOF) to detect the low concentration DNA. The dielectric film of MgF2 helped to enhance the penetration depth of surface plasmon polaritons and to achieve the long-range surface plasmon resonance (LRSPR) which was utilized to detect the micron-size molecule of DNA. The composite film-coated MOF immersed in mercaptoethylamine (MEA) solution to aminate and then functionalized with COOH-modified probe DNA (pDNA) to fabricate the sensing probe. Experimental results showed that the fabricated sensing probe was sensitive to the target DNA (tDNA) with an ultra-low concentration of 2 μ M, but insensitive to the non-target DNA (nonDNA). The proposed sensor, showing the merits of label-free, in-situ, real-time, specificity, stability, and high sensitivity, could be a competitive candidate in DNA detection.
- 22 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. 42 (17) , 6099-6107
Study of Cryogenic Temperature Sensing Based on an All-Fiber Sagnac Loop With High Sensitivity and Wide Measurement Range
Fiber optic-based cryogenic temperature sensing has vital applications in aerospace, biomedicines, food, and energy storage. However, the current fiber optic-based cryogenic temperature sensors have the problems of low sensitivity and narrow sensing range. In this study, we experimentally investigated the cryogenic temperature sensing based on an all-fiber Sagnac loop using a panda polarization maintaining fiber (PPMF) and a fiber Bragg grating (FBG). Modeling simulation of PPMF under cryogenic temperature proved that it could be used for cryogenic temperature sensing in Sagnac loop. FBG, which showed a low but linear temperature response, was used to mark the dip wavelength in Sagnac loop as the movement of dip wavelength exceeding a free spectrum range ( FSR ). The proposed sensor showed a temperature measurement sensitivity of 0.943 nm/°C and a wide measurement range of −103.15–46.85 °C. Furthermore, the proposed sensor also depicted good hysteresis and stability. The study in this paper, which provides an idea to detect cryogenic temperature with high sensitivity and wide measurement range, offers a choice for remote and precise monitoring of cryogenic temperature.
- 22 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. 42 (17) , 6099-6107
Study of Cryogenic Temperature Sensing Based on an All-Fiber Sagnac Loop With High Sensitivity and Wide Measurement Range
Fiber optic-based cryogenic temperature sensing has vital applications in aerospace, biomedicines, food, and energy storage. However, the current fiber optic-based cryogenic temperature sensors have the problems of low sensitivity and narrow sensing range. In this study, we experimentally investigated the cryogenic temperature sensing based on an all-fiber Sagnac loop using a panda polarization maintaining fiber (PPMF) and a fiber Bragg grating (FBG). Modeling simulation of PPMF under cryogenic temperature proved that it could be used for cryogenic temperature sensing in Sagnac loop. FBG, which showed a low but linear temperature response, was used to mark the dip wavelength in Sagnac loop as the movement of dip wavelength exceeding a free spectrum range ( FSR ). The proposed sensor showed a temperature measurement sensitivity of 0.943 nm/°C and a wide measurement range of −103.15–46.85 °C. Furthermore, the proposed sensor also depicted good hysteresis and stability. The study in this paper, which provides an idea to detect cryogenic temperature with high sensitivity and wide measurement range, offers a choice for remote and precise monitoring of cryogenic temperature.
- 4 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (22) , 28075-28083
A Dual-Channel Sensor Based on Long-Range Surface Plasmon Resonance for BSA Concentration and Temperature Measurement
Temperature greatly influences the activity of biological materials. Therefore, it is necessary to simultaneously monitor the temperature and concentration of biological materials. Long-range surface plasmon resonance (LRSPR) sensor has high sensitivity and can detect biomolecules. In this paper, we proposed a dual-channel LRSPR sensor that can measure both bovine serum albumin (BSA) concentration and ambient temperature. The proposed sensor utilized a no-core fiber (NCF) with two channels. One channel was used to deposit magnesium fluoride and silver films on NCF for BSA detection, while the other channel was used to deposit three layers of films (magnesium fluoride, silver, and polydimethylsiloxane (PDMS)) on NCF for temperature detection. The sensitivity of the sensor to detect BSA concentration and temperature is 1.02 nm/(mg/ml) and -2.82 nm/ °C respectively. Cross-sensitivity between the two parameters is solved using a matrix. The sensor offers the advantages of simultaneously monitoring two parameters, having a simple structure, and possessing high sensitivity, which makes it promising for a broad range of applications in monitoring BSA concentration and temperature.
- 4 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (22) , 28075-28083
A Dual-Channel Sensor Based on Long-Range Surface Plasmon Resonance for BSA Concentration and Temperature Measurement
Temperature greatly influences the activity of biological materials. Therefore, it is necessary to simultaneously monitor the temperature and concentration of biological materials. Long-range surface plasmon resonance (LRSPR) sensor has high sensitivity and can detect biomolecules. In this paper, we proposed a dual-channel LRSPR sensor that can measure both bovine serum albumin (BSA) concentration and ambient temperature. The proposed sensor utilized a no-core fiber (NCF) with two channels. One channel was used to deposit magnesium fluoride and silver films on NCF for BSA detection, while the other channel was used to deposit three layers of films (magnesium fluoride, silver, and polydimethylsiloxane (PDMS)) on NCF for temperature detection. The sensitivity of the sensor to detect BSA concentration and temperature is 1.02 nm/(mg/ml) and -2.82 nm/ °C respectively. Cross-sensitivity between the two parameters is solved using a matrix. The sensor offers the advantages of simultaneously monitoring two parameters, having a simple structure, and possessing high sensitivity, which makes it promising for a broad range of applications in monitoring BSA concentration and temperature.
- 18 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-6
Refractive Index and Temperature Sensing System With High Sensitivity and Large Measurement Range Using an Optical Fiber
In this paper, a temperature and refractive index sensing probe based on a photonic crystal fiber (PCF) with a silver film coating is proposed. We suggested a simple method for coating silver films, and a silver film was coated on the periphery of the PCF that solve the previous difficulties of coating metal film inside the air holes or polishing a flat surface. The sensing probe has achieved dual-parameters sensing of refractive index and temperature by employing Polydimethylsiloxane (PDMS) as the temperature-sensitive material. The results of the experiment demonstrated that the wide measurement range and high sensitivity of the sensing probe. It has a refractive index sensitivity of 3341.65 nm/RIU in the range of 1.333–1.3953 and a temperature sensitivity of 2.02 nm/°C in the range of 50–100 °C. The features of the suggested sensing probe, including its simple structure and ease of production, indicate potential application in the field of biochemical sensing.
- 18 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-6
Refractive Index and Temperature Sensing System With High Sensitivity and Large Measurement Range Using an Optical Fiber
In this paper, a temperature and refractive index sensing probe based on a photonic crystal fiber (PCF) with a silver film coating is proposed. We suggested a simple method for coating silver films, and a silver film was coated on the periphery of the PCF that solve the previous difficulties of coating metal film inside the air holes or polishing a flat surface. The sensing probe has achieved dual-parameters sensing of refractive index and temperature by employing Polydimethylsiloxane (PDMS) as the temperature-sensitive material. The results of the experiment demonstrated that the wide measurement range and high sensitivity of the sensing probe. It has a refractive index sensitivity of 3341.65 nm/RIU in the range of 1.333–1.3953 and a temperature sensitivity of 2.02 nm/°C in the range of 50–100 °C. The features of the suggested sensing probe, including its simple structure and ease of production, indicate potential application in the field of biochemical sensing.
- 27 November 2022
- Published by Elsevier in Optics & Laser Technology
- Vol. 159
Sagnac interferometer-based optical fiber strain sensor with exceeding free spectral measurement range and high sensitivity
- 27 November 2022
- Published by Elsevier in Optics & Laser Technology
- Vol. 159
Sagnac interferometer-based optical fiber strain sensor with exceeding free spectral measurement range and high sensitivity
- 27 April 2022
- Published by Optica Publishing Group in Journal of the Optical Society of America B
- Vol. 39 (5) , 1449-1456
Analysis of filtering and refractive index sensing characteristics based on gold-coated photonic crystal fiber
A gold-coated photonic crystal fiber (PCF) with dual functions of filtering and refractive index sensing is proposed. The gold layer is deposited in two open grooves, which make it easy to manufacture. For the filtering characteristics, it can achieve high loss at the wavelength of 1550 nm. The results show that the confinement losses of the x - and y -polarized modes are 0.012 dB/cm and 445.10 dB/cm, respectively. When the crosstalk is greater than 20 dB, it shows high bandwidth of 910 nm for the PCF length of 3 mm. For the sensing characteristics, it shows a maximum sensitivity of 4000 nm/RIU for an analyte range of 1.39–1.40. It also has a high figure of merit with a maximum value of 45.45 R I U − 1 and a low detection limit (56.13 nm). Owing to the excellent performance of the gold-coated PCF in filtering and sensing, it will become a suitable candidate for optical communication and sensing systems.
- 27 April 2022
- Published by Optica Publishing Group in Journal of the Optical Society of America B
- Vol. 39 (5) , 1449-1456
Analysis of filtering and refractive index sensing characteristics based on gold-coated photonic crystal fiber
A gold-coated photonic crystal fiber (PCF) with dual functions of filtering and refractive index sensing is proposed. The gold layer is deposited in two open grooves, which make it easy to manufacture. For the filtering characteristics, it can achieve high loss at the wavelength of 1550 nm. The results show that the confinement losses of the x - and y -polarized modes are 0.012 dB/cm and 445.10 dB/cm, respectively. When the crosstalk is greater than 20 dB, it shows high bandwidth of 910 nm for the PCF length of 3 mm. For the sensing characteristics, it shows a maximum sensitivity of 4000 nm/RIU for an analyte range of 1.39–1.40. It also has a high figure of merit with a maximum value of 45.45 R I U − 1 and a low detection limit (56.13 nm). Owing to the excellent performance of the gold-coated PCF in filtering and sensing, it will become a suitable candidate for optical communication and sensing systems.
- 26 February 2020
- Published by Springer Nature
- p. 690-698
Computer Numerical Simulation of Force-Magnetic Coupling for Steel Wire Rope with Defect
- 26 February 2020
- Published by Springer Nature
- p. 690-698
Computer Numerical Simulation of Force-Magnetic Coupling for Steel Wire Rope with Defect