HIHrishikesh Iyer

Hrishikesh Iyer

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Hrishikesh Iyer has a total of 47 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Ultra-high numerical aperture waveguide-integrated meta beam shaper

    by Hrishikesh Iyer, Yurii Vlasov

    The integration of metasurfaces with guided mode sources like waveguides has opened new frontiers for on-chip optical integration. However, the state-of-the-art in the field has targeted applications where long focal distances over thousands of light wavelengths are needed. This regime where the paraxial approximation holds enables inverse design of metasurfaces with weakly confining elements that are typically thicker than the wavelength in the material. For short focal length applications at distances less than 100λ, where the paraxial approximation fails and high numerical apertures (NAs) are necessary, a different approach is required. Here, we designed and experimentally demonstrated single-mode waveguide-integrated meta beam shapers capable of redirecting the confined light into the free space and focusing it at focal distances less than 100λ above the chip surface into a tightly focused spot. Focal spot characteristics measured at 460 nm operating wavelength approach diffraction-limited focusing across a range of focal lengths, device footprints, and numerical apertures, demonstrating the robustness of the approach. Focal volumes smaller than 1µm3 are demonstrated for a range of focal distances below 50 µm (100λ). For a device with NA of 0.95 that is one of the highest amongst integrated metasurfaces, the measured focal volume is as small as just 0.06µm3 at a focal distance of 13µm (28λ). These on-chip integrated ultra-high NA meta beam shapers have the potential to unlock new applications in quantum optical computing with trapped ions, localized optogenetic neurostimulation, and high resolution in situ microscopy.


  • Open Access

    Highly localized chemical sampling at sub-second temporal resolution enabled with a silicon nanodialysis platform at exceedingly slow flows

    by Insu Park, Sungho Kim, Christopher Kenji Brenden, Weihua Shi, Hrishikesh Iyer, Rashid Bashir, Yurii Vlasov

    Microdialysis (MD) is a versatile and powerful technique for chemical profiling of biological tissues and is widely used for quantification of neurotransmitters, neuropeptides, metabolites, biomarkers, and drugs in the central nervous system as well as in dermatology, ophthalmology, and in pain research. However, MD performance is severely limited by fundamental tradeoffs between chemical sensitivity, spatial resolution, and temporal response. Here, by using wafer-scale silicon microfabrication, we develop and demonstrate a nanodialysis (ND) sampling probe that enables highly localized chemical sampling with 100μm spatial resolution and sub-second temporal resolution at high recovery rates. These performance metrics, which are 100X-1000X superior to existing MD approaches, are enabled by a 100X reduction of the microfluidic channel cross-section, a corresponding drastic 100X reduction of flow rates to exceedingly slow few nL/min flows, and integration of a nanometer-thin nanoporous membrane with high transport flux into the probe sampling area. Miniaturized ND probes may allow for the minimally invasive and highly localized sampling and chemical profiling in live biological tissues with unprecedented spatio-temporal resolution for clinical, biomedical, and pharmaceutical applications.

  • Open Access

    Integrated silicon microfluidic chip for picoliter-scale analyte segmentation and microscale printing for mass spectrometry imaging

    by Weihua Shi, Sara Bell, Hrishikesh Iyer, Christopher Kenji Brenden, Yan Zhang, Sungho Kim, Insu Park, Rashid Bashir, Jonathan Sweedler, Yurii Vlasov

    A silicon integrated microfluidics system prints picoliter-segmented analytes for attomole-level chemical analysis with mass spectrometry imaging.


  • Open Access

    India’s First Robotic Eye for Time-domain Astrophysics: The GROWTH-India Telescope

    by Harsh Kumar, Varun Bhalerao, G. C. Anupama, Sudhanshu Barway, Judhajeet Basu, Kunal Deshmukh, Kishalay De, Anirban Dutta, Christoffer Fremling, Hrishikesh Iyer, et al.

    We present the design and performance of the GROWTH-India telescope, a 0.7 m robotic telescope dedicated to time-domain astronomy. The telescope is equipped with a 4k back-illuminated camera that gives a 0.°82 field of view and a sensitivity of m g′ ∼ 20.5 in 5 minute exposures. Custom software handles observatory operations: attaining high on-sky observing efficiencies (≳80%) and allowing rapid response to targets of opportunity. The data processing pipelines are capable of performing point-spread function photometry as well as image subtraction for transient searches. We also present an overview of the GROWTH-India telescope’s contributions to the studies of gamma-ray bursts, the electromagnetic counterparts to gravitational wave sources, supernovae, novae, and solar system objects.