Soroush Dehghani
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Soroush Dehghani has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Thomas Johnson
School of Engineering, Faculty of Applied Science, The University of British Columbia, Kelowna, BC, Canada
2 shared publications - Ehsan Samiei
Department of Mechanical and Industrial Engineering, University of Toronto, 5 King's College Rd, Toronto, M5S 1A1, Canada
1 shared publication - George Luka
Department of Electrical and Computer Engineering, University of California, Santa Cruz, CA 95064, USA
1 shared publication - Homayoun Najjaran
University of Victoria
1 shared publication - Mina Hoorfar
Department of Mechanical Engineering, University of Victoria, Victoria, BC V8P 5C2, Canada
1 shared publication - Shahriar Mirabbasi
Department of Electrical and Computer Engineering, The University of British Columbia, Vancouver, BC, Canada
1 shared publication
Latest Publications
- Open Access
Label-Free Capacitive Biosensor for Detection of Cryptosporidium
Cryptosporidium, an intestinal protozoan pathogen, is one of the leading causes of diarrhea in healthy adults and death in children. Detection of Cryptosporidium oocysts has become a high priority to prevent potential outbreaks. In this paper, a label-free interdigitated-based capacitive biosensor has been introduced for the detection of Cryptosporidium oocysts in water samples. Specific anti-Cryptosporidium monoclonal antibodies (IgG3) were covalently immobilized onto interdigitated gold electrodes as the capture probes, and bovine serum albumin was used to avoid non-specific adsorption. The immobilization of the antibodies was confirmed by measuring the change in the contact angle. The detection was achieved by measuring the relative change in the capacitive/dielectric properties due to the formation of Cryptosporidium-antibody complex. The biosensor has been tested for different concentrations of Cryptosporidium. The results show that the biosensor developed can accurately distinguish different numbers of captured cells and densities on the surface of the biosensor. The number of Cryptosporidium oocysts captured on the electrode surface was confirmed using a fluorescein isothiocyanate (FITC) immunofluorescence assay. The response from the developed biosensor has been mainly dependent on the concentration of Cryptosporidium under optimized conditions. The biosensor showed a linear detection range between 15 and 153 cells/mm2 and a detection limit of 40 cells/mm2. The label-free capacitive biosensor developed has a great potential for detecting Cryptosporidium in environmental water samples. Furthermore, under optimized conditions, this label-free biosensor can be extended for detection of other biomarkers for biomedical and environmental analyses.
Open AccessLabel-Free Capacitive Biosensor for Detection of Cryptosporidium
Cryptosporidium, an intestinal protozoan pathogen, is one of the leading causes of diarrhea in healthy adults and death in children. Detection of Cryptosporidium oocysts has become a high priority to prevent potential outbreaks. In this paper, a label-free interdigitated-based capacitive biosensor has been introduced for the detection of Cryptosporidium oocysts in water samples. Specific anti-Cryptosporidium monoclonal antibodies (IgG3) were covalently immobilized onto interdigitated gold electrodes as the capture probes, and bovine serum albumin was used to avoid non-specific adsorption. The immobilization of the antibodies was confirmed by measuring the change in the contact angle. The detection was achieved by measuring the relative change in the capacitive/dielectric properties due to the formation of Cryptosporidium-antibody complex. The biosensor has been tested for different concentrations of Cryptosporidium. The results show that the biosensor developed can accurately distinguish different numbers of captured cells and densities on the surface of the biosensor. The number of Cryptosporidium oocysts captured on the electrode surface was confirmed using a fluorescein isothiocyanate (FITC) immunofluorescence assay. The response from the developed biosensor has been mainly dependent on the concentration of Cryptosporidium under optimized conditions. The biosensor showed a linear detection range between 15 and 153 cells/mm2 and a detection limit of 40 cells/mm2. The label-free capacitive biosensor developed has a great potential for detecting Cryptosporidium in environmental water samples. Furthermore, under optimized conditions, this label-free biosensor can be extended for detection of other biomarkers for biomedical and environmental analyses.
- 17 April 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Solid-State Circuits Letters
- Vol. 1 (3) , 66-69
A 5.8-GHz Bidirectional and Reconfigurable RF Energy Harvesting Circuit With Rectifier and Oscillator Modes
A bidirectional circuit that can be reconfigured as a receiver for rectifying radio-frequency (RF) power for energy harvesting, and as a power oscillator for transmission, is proposed. The circuit is compact and suitable for integration in time-division multiplexed wireless sensors. A design concept based on time-reversal duality theory is employed to reuse the same circuit elements for both the oscillator and the rectifier modes by reconfiguring power flow between the dc and RF ports. A proof-of-concept prototype circuit using a high-efficiency class-DE circuit topology is implemented in a 65-nm CMOS technology. The circuit operates at a frequency of 5.8 GHz, and the measured peak efficiency is greater than 50% in both operating modes.
- 17 April 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Solid-State Circuits Letters
- Vol. 1 (3) , 66-69
A 5.8-GHz Bidirectional and Reconfigurable RF Energy Harvesting Circuit With Rectifier and Oscillator Modes
A bidirectional circuit that can be reconfigured as a receiver for rectifying radio-frequency (RF) power for energy harvesting, and as a power oscillator for transmission, is proposed. The circuit is compact and suitable for integration in time-division multiplexed wireless sensors. A design concept based on time-reversal duality theory is employed to reuse the same circuit elements for both the oscillator and the rectifier modes by reconfiguring power flow between the dc and RF ports. A proof-of-concept prototype circuit using a high-efficiency class-DE circuit topology is implemented in a 65-nm CMOS technology. The circuit operates at a frequency of 5.8 GHz, and the measured peak efficiency is greater than 50% in both operating modes.